About the UFC Program

The Unified Facilities Criteria (UFC) Program provides planning, design, construction, sustainment, restoration, and modernization criteria for Department of Defense (DoD) facilities. These criteria apply to the Military Departments, Defense Agencies, and DoD Field Activities in accordance with DoD Directive 4270.5 (Military Construction) and the USD(AT&L) MemorandumDownload ufc_implementation.pdf dated 29 May 2002. UFC program content is distributed exclusively in electronic format and are effective upon issuance.

The UFC Program is jointly administered by the United States Army Corps of Engineers (HQUSACE), Naval Facilities Engineering Systems Command (NAVFAC), and the Air Force Civil Engineer Center (AFCEC). Program procedures and points of contact are outlined in the current edition of MIL-STD-3007.

Program Structure: UFC, UFS, and UFM

The UFC Program delivers consistent technical content through three types of unified components:

  • Unified Facilities Criteria (UFC): Technical requirements, laws, and policies applicable across all DoD Components. This criterion is considered mandatory unless a waiver is granted. UFC may contain Commentary as indicated by [C]. This Commentary is helpful information to expand upon the UFC criteria.
  • Unified Facilities Supplement (UFS): Unified Facilities Supplements contain guidance, best practices, checklists, procedures, examples, and/or component-specific needs. UFS content is not mandatory unless invoked by other means, including but not limited to component or higher-level policy, UFCs, or contractual requirements.
  • Unified Facilities Operations & Maintenance Manual (UFM): Operations and Maintenance Manuals guide users respecting system and equipment use, safety measures, maintenance schedules, and troubleshooting. Contents may expand on requirements elsewhere. UFM content is not mandatory unless invoked by other means, including but not limited to component or higher-level policy, UFCs, or contractual requirements.

Together, this unified criteria program ensures consistent standards for safety, sustainability, durability, and functionality. UFCs incorporate building codes, DoD requirements, and applicable statutory provisions. UFC content that is fully unified and applicable across all DoD Components have no alphabetical suffix in the title.

Non-Unified Content: FC, FS, FM

When content is developed for a specific agency or limited audience, it is reclassified as:

  • Facilities Criteria (FC): Non-unified counterpart to UFC, tailored to specific facility or Component needs.
  • Facilities Supplements (FS): Non-unified counterpart to UFS, providing Component-specific technical or contextual content. This is not criteria and is provided For Information Only (FIO).
  • Facilities Manuals (FM): Non-unified counterpart to UFM, delivering O&M content for Component-specific requirements.

Non-unified documents include a letter at the end of their number to show the sponsoring Component:

  • A — U.S. Army Corps of Engineers (USACE)
  • N — Naval Facilities Engineering Systems Command (NAVFAC)
  • F — Air Force Civil Engineer Center (AFCEC)

If applicable to multiple agencies, multiple letters are used (e.g., AF for Army and Air Force).

Glossary and References

Glossary terms will no longer be included in UFCs. Instead, you may find this information at the following:

Questions and Change Requests

Suggestions, comments, and recommended changes to UFC Program documents are encouraged and should be submitted via a Criteria Change Request (CCR). To submit a CCR, click the CCR link provided next to each document. CCRs should not be used for project-specific issues, such as solicitation or contract interpretation. These matters should be directed to the appropriate Contracting Officer.

To learn more about how changes are classified, refer to the UFC—UFGS Revision-Change PolicyDownload ufc_ufgs_chg_rev_policy.pdf.

 A paperclip icon next to a UFC title indicates an attachment is available. Click the title to view the related materials.

 

? Active: Document is current, regularly maintained by the responsible DWG through formal revisions and changes, and must be used in accordance with its applicability paragraphs.

Inactive: Document is not regularly maintained due to limited use. May be used for new projects per applicability paragraphs, but users must verify content relevancy and accept responsibility for using potentially outdated information.

Archived: Document is outdated or superseded and not maintained. Prohibited for use in new projects. Available only for historical reference or for existing projects that previously cited the document before archival.


TITLE Date Change Date View CCR
UFC Complete  
UFC 1-200-01 DoD Building Code, with Change 4   PDF Download ufc_1_200_01_2022_c4.pdf CCR  
UFC 1-200-02 High Performance and Sustainable Building Requirements, with Change 3   PDF Download ufc_1_200_02_2020_c3.pdf CCR  
UFC 1-201-01 Non-Permanent DoD Facilities in Support of Military Operations, with Change 4   PDF Download ufc_1_201_01_2022_c4.pdf CCR  
UFS 1-201-02 Assessment of Existing Facilities for Use in Military Operations   PDF Download ufs_1_201_02_2025.pdf CCR  
UFC 1-202-01 Host Nation Facilities in Support of Military Operations   PDF Download ufc_1_202_01_2013.pdf
UFS 1-300-01 Criteria Format Standard   PDF Download ufs_1_300_01_2026.pdf CCR  
UFS 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard   PDF Download ufs_1_300_02_2025.pdf CCR  
UFC 1-300-05A Installation Support   PDF Download ufc_1_300_05a_2004.pdf
UFC 1-300-07A Design Build Technical Requirements   PDF Download ufc_1_300_07a_2005.pdf
UFS 1-300-08 Criteria for Transfer and Acceptance of DoD Real Property   PDF Download ufs_1_300_08_2026.pdf CCR  
FC 1-300-09N Navy and Marine Corps Design Procedures, with Change 1   PDF Download fc_1_300_09n_2024_c1.pdf CCR  
UFC 1-900-01 Selection of Methods for the Reduction, Reuse, and Recycling of Demolition Waste; Canceled without Replacement   PDF Download ufc_1_900_01_2002.pdf
UFC 2-000-01 Army Planning and Design Execution in the National Capital Region   PDF Download ufc_2_000_01_2004.pdf
UFC 2-000-02AN Installation Master Planning, Replaced by UFC 2-100-01   PDF Download ufc_2_000_02an_2005.pdf
FC 2-000-05N Facility Planning Criteria for Navy and Marine Corps Shore Installations  
UFS 2-100-01 Installation Master Planning   PDF Download ufs_2_100_01_2026.pdf CCR  
UFC 3-101-01 Architecture, with Change 4   PDF Download ufc_3_101_01_2020_c4.pdf CCR  
UFC 3-110-03 Roofing, with Change 5   PDF Download ufc_3_110_03_2012_c5.pdf CCR  
UFC 3-110-04 Roofing Maintenance and Repair   PDF Download ufc_3_110_04_2007.pdf
UFC 3-120-01 Design: Sign Standards, with Change 4   PDF Download ufc_3_120_01_2014_c4.pdf CCR  
UFC 3-120-10 Interior Design, with Change 3   PDF Download ufc_3_120_10_2018_c3.pdf CCR  
UFC 3-130-01 Arctic and Subarctic Engineering   PDF Download ufc_3_130_01_2024.pdf CCR  
UFC 3-130-02 Arctic and Subarctic Site Assessment and Selection   PDF Download ufc_3_130_02_2025.pdf CCR  
UFC 3-130-03 Arctic and Subarctic Foundations for Freezing and Thawing Conditions   PDF Download ufc_3_130_03_2025.pdf CCR  
UFC 3-130-04 Arctic and Subarctic Buildings   PDF Download ufc_3_130_04_2025.pdf CCR  
UFC 3-130-04 (2004) Foundations for Structures - Arctic and Subarctic Construction   PDF Download ufc_3_130_04_2004.pdf
UFC 3-130-05 Arctic and Subarctic Utilities   PDF Download ufc_3_130_05_2025.pdf CCR  
UFC 3-130-06 Calculation Methods for Determination of Depths of Freeze and Thaw in Soil - Arctic and Subarctic Construction   PDF Download ufc_3_130_06_2004.pdf
UFC 3-130-07 Buildings - Arctic and Subarctic Construction   PDF Download ufc_3_130_07_2004.pdf
UFC 3-190-01FA Joint Sealing for Buildings, Canceled without Replacement   PDF Download ufc_3_190_01fa_2003.pdf
UFC 3-190-02FA Builders Hardware, Cancelled without Replacement   PDF Download ufc_3_190_02fa.pdf
UFC 3-190-03A X-Ray Shielding   PDF Download ufc_3_190_03a_2003.pdf
UFC 3-190-04FA Roofing and Waterproofing, Replaced by UFC 3-110-03   PDF Download ufc_3_190_04fa.pdf
UFS 3-190-06 Protective Coatings and Paints   PDF Download ufs_3_190_06_2026.pdf CCR  
UFC 3-190-07N Food Service Equipment Operation and Maintenance   PDF Download ufc_3_190_07n_2004.pdf
UFC 3-201-01 Civil Engineering   PDF Download ufc_3_201_01_2022.pdf CCR  
UFC 3-201-02 Landscape Architecture, with Change 1   PDF Download ufc_3_201_02_2020_c1.pdf CCR  
UFC 3-210-01A Design: Area Planning, Site Planning, and Design, Replaced by 3-201-01   PDF Download ufc_3_210_01a_2004.pdf
UFC 3-210-02 POV Site Circulation and Parking, with Change 1, Replaced by UFC 3-201-01   PDF Download ufc_3_210_02_2004_c1.pdf
UFC 3-210-03A Planning of Outdoor Recreation Facilities, Replaced by UFC 3-201-01   PDF Download ufc_3_210_03a_2004.pdf
UFC 3-210-04 Children's Outdoor Play Area   PDF Download ufc_3_210_04_2004.pdf
UFC 3-210-05FA Landscape Design and Planning Criteria, Replaced by UFC 3-201-02   PDF Download ufc_3_210_05fa.pdf
UFC 3-210-06A Site Planning and Design, Replaced by UFC 3-201-01   PDF Download ufc_3_210_06a_2006.pdf
UFC 3-210-10 Low Impact Development   PDF Download ufc_3_210_10_2023.pdf CCR  
UFC 3-220-01 Geotechnical Engineering, with Change 3   PDF Download ufc_3_220_01_2012_c3.pdf CCR  
UFC 3-220-01A Deep Foundations, Replaced by UFC 3-220-01   PDF Download ufc_3_220_01a_2004.pdf
UFC 3-220-01N Geotechnical Engineering Procedures for Foundation Design of Buildings and Structures, Replaced by UFC 3-220-01   PDF Download ufc_3_220_01n_2005.pdf
UFC 3-220-02 Pile Driving Equipment, Replaced by UFC 3-220-01   PDF Download ufc_3_220_02_2004.pdf
UFC 3-220-03FA Soils and Geology Procedures for Foundation Design of Buildings and Other Structures (Except Hydraulic Structures), Replaced by UFC 3-220-01   PDF Download ufc_3_220_03fa_2004.pdf
UFC 3-220-04FA Backfill for Subsurface Structures   PDF Download ufc_3_220_04fa_2004.pdf
UFC 3-220-05 Dewatering and Groundwater Control   PDF Download ufc_3_220_05_2004.pdf
UFC 3-220-06 Grouting Methods and Equipment   PDF Download ufc_3_220_06_2004.pdf
UFC 3-220-07 Foundations in Expansive Soils, Replaced by UFC 3-220-01   PDF Download ufc_3_220_07_2004.pdf
UFC 3-220-08FA Engineering Use of Geotextiles   PDF Download ufc_3_220_08fa_2004.pdf
UFS 3-220-10 Soil Mechanics (DM 7.1)   PDF Download ufs_3_220_10_2026.pdf CCR  
UFS 3-220-20 Foundations and Earth Structures (DM 7.2)   PDF Download ufs_3_220_20_2026.pdf CCR  
UFC 3-230-01 Water Storage and Distribution with Change 3   PDF Download ufc_3_230_01_2018_c3.pdf CCR  
UFM 3-230-02 O&M: Water Supply Systems,   PDF Download ufm_3_230_02_2026.pdf CCR  
UFC 3-230-03 Water Treatment, with Change 2   PDF Download ufc_3_230_03_2012_c2.pdf CCR  
UFC 3-230-03A Water Supply, Replaced by UFC 3-230-01   PDF Download ufc_3_230_03a_2004.pdf
UFC 3-230-04A Water Distribution, Replaced by UFC 3-230-01   PDF Download ufc_3_230_04a_2004.pdf
UFC 3-230-06A Subsurface Drainage, with Changes 1-2   PDF Download ufc_3_230_06a_2004_c2.pdf
UFC 3-230-07A Water Supply: Sources and General Considerations, Replaced by UFC 3-230-01   PDF Download ufc_3_230_07a_2004.pdf
UFC 3-230-08A Water Supply: Water Treatment, Replaced by UFC 3-230-03   PDF Download ufc_3_230_08a_2004.pdf
UFC 3-230-09A Water Supply: Water Storage, Replaced by UFC 3-230-01   PDF Download ufc_3_230_09a_2004.pdf
UFC 3-230-10A Water Supply: Water Distribution, Replaced by UFC 3-230-01   PDF Download ufc_3_230_10a_2004.pdf
UFC 3-230-11A Water Supply for Special Projects, Replaced by UFC 3-230-01   PDF Download ufc_3_230_11a_2004.pdf
UFC 3-230-12A Water Desalination, Replaced by UFC 3-230-03   PDF Download ufc_3_230_12a_2004.pdf
UFM 3-230-13 Industrial Water Treatment Operation and Maintenance   PDF Download ufm_3_230_13_2026.pdf CCR  
UFC 3-230-13A Water Supply: Pumping Stations, Replaced by UFC 3-230-01   PDF Download ufc_3_230_13a_2004.pdf
UFC 3-230-14A Evaluation Criteria Guide for Water Pollution Prevention Control and Abatement Programs, Canceled without Replacement   PDF Download ufc_3_230_14a_2004.pdf
UFC 3-230-15FA Surface Drainage Facilities for Airfields and Heliports, Replaced by UFC 3-230-01   PDF Download ufc_3_230_15fa_2004.pdf
UFC 3-230-16FA Drainage and Erosion Control Structures for Airfields and Heliports, Replaced by UFC 3-230-01   PDF Download ufc_3_230_16fa_2004.pdf
UFC 3-230-17FA Drainage in Areas Other than Airfields, Replaced by UFC 3-201-01   PDF Download ufc_3_230_17fa_2004.pdf
UFC 3-230-19N Water Supply Systems, Replaced by UFC 3-230-01   PDF Download ufc_3_230_19n_2005.pdf
UFC 3-240-01 Wastewater Collection and Treatment, with Change 4   PDF Download ufc_3_240_01_2020_c4.pdf CCR  
UFS 3-240-02 Water Reuse   PDF Download ufs_3_240_02_2026.pdf CCR  
UFC 3-240-02 Domestic Wastewater Treatment, with Change 1   PDF Download ufc_3_240_02_2012_c1.pdf
UFC 3-240-02N Wastewater Treatment System Augmenting Handbook, Replaced by UFC 3-240-02   PDF Download ufc_3_240_02n_2004.pdf
UFM 3-240-03 Operation and Maintenance (O&M): Wastewater Treatment   PDF Download ufm_3_240_03_2026.pdf CCR  
UFC 3-240-03N Wastewater Treatment System Augmenting Handbook Operation and Maintenance   PDF Download ufc_3_240_03n_2004.pdf
UFC 3-240-04A Wastewater Collection, Replaced by UFC 3-240-01   PDF Download ufc_3_240_04a_2004.pdf
UFC 3-240-05A Solid Waste Incineration   PDF Download ufc_3_240_05a_2004.pdf
UFC 3-240-06A Wastewater Collection and Pumping, Replaced by UFC 3-240-01   PDF Download ufc_3_240_06a_2004.pdf
UFC 3-240-07FA Sanitary and Industrial Wastewater Collection: Gravity Sewers and Appurtenances, Replaced by UFC 3-240-01   PDF Download ufc_3_240_07fa_2004.pdf
UFC 3-240-08FA Sanitary and Industrial Wastewater Collection: Pumping Stations and Force Mains, Replaced by UFC 3-240-01   PDF Download ufc_3_240_08fa_2004.pdf
UFC 3-240-09FA Domestic Wastewater Treatment, Replaced by UFC 3-240-02   PDF Download ufc_3_240_09fa_2004.pdf
UFC 3-240-10A Sanitary Landfill   PDF Download ufc_3_240_10a_2004.pdf
UFC 3-240-11 Landfills in Support of Military Operations   PDF Download ufc_3_240_11_2021.pdf CCR  
UFC 3-240-14N Solid Waste Disposal, Cancelled without Replacement   PDF Download ufc_3_240_14n_2004.pdf
UFC 3-250-01 Pavement Design for Roads and Parking Areas   PDF Download ufc_3_250_01_2016.pdf CCR  
UFC 3-250-01FA Pavement Design for Roads, Streets, Walks, and Open Storage Areas, Replaced by UFC 3-250-01   PDF Download ufc_3_250_01fa_2004.pdf
UFS 3-250-03 Standard Practice for Flexible Pavements   PDF Download ufs_3_250_03_2026.pdf CCR  
UFS 3-250-04 Standard Practice for Concrete Pavement Construction   PDF Download ufs_3_250_04_2026.pdf CCR  
UFC 3-250-04FA Standard Practice for Concrete Pavements, Replaced by UFC 3-250-04   PDF Download ufc_3_250_04fa_2004.pdf
UFC 3-250-06 Repair of Rigid Pavements Using Epoxy Resin Grouts, Mortars and Concretes, Replaced by UFC 3-270-01 O&M Manual: Asphalt and Concrete Pavement Maintenance and Repair   PDF Download ufc_3_250_06_2004.pdf
UFM 3-250-07 O&M Manual: Standard Practice for Pavement Recycling   PDF Download ufm_3_250_07_2026.pdf CCR  
UFC 3-250-08FA Standard Practice for Sealing Joints and Cracks in Rigid and Flexible Pavements   PDF Download ufc_3_250_08fa_2004.pdf
UFC 3-250-09FA Aggregate Surfaced Roads and Airfields Areas   PDF Download ufc_3_250_09fa_2004.pdf
UFC 3-250-10FA Pavement Design for Roads, Streets and Open Storage Areas, Elastic Layered Methods   PDF Download ufc_3_250_10fa_2004.pdf
UFS 3-250-11 Soil Stabilization and Modification for Pavements   PDF Download ufs_3_250_11_2026.pdf CCR  
UFC 3-250-12N Design: Pavements, Replaced by UFC 3-250-04   PDF Download ufc_3_250_12n_2005.pdf
UFC 3-250-18FA General Provisions and Geometric Design for Roads, Streets, Walks, and Open Storage Areas, Replaced by UFC 3-201-01   PDF Download ufc_3_250_18fa_2006.pdf
UFC 3-260-01 Airfield and Heliport Planning and Design, with Change 3   PDF Download ufc_3_260_01_2019_c3.pdf CCR  
UFC 3-260-01 Airfield and Heliport Planning and Design, with Changes 1-2, Replaced by UFC 3-260-01   PDF Download ufc_3_260_01_2001.pdf
UFC 3-260-02 Pavement Design for Airfields   PDF Download ufc_3_260_02_2001.pdf CCR  
UFM 3-260-03 O&M Manual: Standard Practice for Airfield Pavement Evaluation   PDF Download ufm_3_260_03_2026.pdf CCR  
UFC 3-260-04 Airfield and Heliport Marking   PDF Download ufc_3_260_04_2018.pdf CCR  
UFC 3-260-05A Marking of Army Airfield Heliport Operational and Maintenance Facilities, with Change 1   PDF Download ufc_3_260_05a_2004.pdf
FC 3-260-06F Air Force Design, Construction, Maintenance, and Evaluation of Snow and Ice Airfields in Antarctica   PDF Download fc_3_260_06f_2015.pdf CCR  
UFC 3-260-11FA Model Design-Build (D-B) Request for Proposal (RFP) For Airfield Contracts   PDF Download ufc_3_260_11fa_2005.pdf
UFM 3-260-16 O&M Manual: Standard Practice for Airfield Pavement Condition Surveys   PDF Download ufm_3_260_16_2026.pdf CCR  
UFC 3-260-16FA Airfield Pavement Condition Survey Procedures Pavements Replaced by UFC 3-260-16 O&M Manual: Standard Practice for Airfield Pavement Condition Surveys   PDF Download ufc_3_260_16fa_2004.pdf
UFM 3-260-17 O&M Manual: Standard Practice for Dust Control on Roads, Airfields, Base Camps, and Adjacent Areas   PDF Download ufm_3_260_17_2026.pdf CCR  
FC 3-260-18F Air Force Aircraft Arresting Systems Installation, Operation, and Maintenance, with Change 1   PDF Download fc_3_260_18f_2015_c1.pdf CCR  
UFM 3-270-01 O&M Manual: Asphalt and Concrete Pavement Maintenance and Repair   PDF Download ufm_3_270_01_2026.pdf CCR  
UFC 3-270-02 Asphalt Crack Repair, Replaced by UFC 3-270-01 O&M Manual: Asphalt and Concrete Pavement Maintenance and Repair   PDF Download ufc_3_270_02_2001.pdf
UFC 3-270-03 Concrete Crack and Partial-Depth Spall Repair, Replaced by UFC 3-270-01 O&M Manual: Asphalt and Concrete Pavement Maintenance and Repair   PDF Download ufc_3_270_03_2001.pdf
UFC 3-270-04 Concrete Repair, Replaced by UFC 3-270-01 O&M Manual: Asphalt and Concrete Pavement Maintenance and Repair   PDF Download ufc_3_270_04_2001.pdf
UFC 3-270-05 Paver Concrete Surfaced Airfields Pavement Condition Index (PCI) Replaced by UFC 3-260-16 O&M Manual: Standard Practice for Airfield Pavement Condition Surveys   PDF Download ufc_3_270_05_2001.pdf
UFC 3-270-06 Paver Asphalt Surfaced Airfields Pavement Condition Index (PCI) Replaced by UFC 3-260-16 O&M Manual: Standard Practice for Airfield Pavement Condition Surveys   PDF Download ufc_3_270_06_2001.pdf
UFC 3-270-07 O&M: Airfield Damage Repair, Superseded by TSPWG M 3-270-01.3-270-07   PDF Download ufc_3_270_07_2002.pdf
UFM 3-270-08 O&M Manual: Pavement Management   PDF Download ufm_3_270_08_2026.pdf CCR  
UFC 3-280-01A Guidance for Ground Water/Fuel Extraction and Ground Water Injection Systems   PDF Download ufc_3_280_01a_2004.pdf
UFC 3-280-02A Hazardous Waste Land Disposal/Land Treatment Facilities, Cancelled without Replacement   PDF Download ufc_3_280_02a_2004.pdf
UFC 3-280-03 Army Plate and Frame Filter Press   PDF Download ufc_3_280_03_2003.pdf
UFC 3-280-04 Army Filtration of Liquids   PDF Download ufc_3_280_04_2003.pdf
UFC 3-300-10N Structural Engineering, with Changes 1-2, Replaced by UFC 3-301-01   PDF Download ufc_3_300_10n_c2.pdf
UFC 3-301-01 Structural Engineering, with Change 6   PDF Download ufc_3_301_01_2023_c6.pdf CCR  
UFC 3-301-02 Design of Risk Category V Structures, National Strategic Military Assets, with Change 1   PDF Download ufc_3_301_02_2023_c1.pdf CCR  
UFC 3-301-05A Seismic Evaluation and Rehabilitation for Buildings, Replaced by UFC 3-310-04   PDF Download ufc_3_301_05a_2005.pdf
UFC 3-310-01 Structural Load Data, with Change 2, Replaced by UFC 3-301-01   PDF Download ufc_3_310_01_2005_c2.pdf
UFC 3-310-02A Structural Design Criteria for Buildings, Replaced by UFC 3-301-01   PDF Download ufc_3_310_02a_2005.pdf
UFC 3-310-03A Seismic Design for Buildings, Replaced by UFC 3-310-04   PDF Download ufc_3_310_03a_2005.pdf
UFC 3-310-04 Seismic Design of Buildings, with Change 1   PDF Download ufc_3_310_04_2013_c1.pdf
UFC 3-310-05A Masonry Structural Design for Buildings, Replaced by UFC 3-301-01   PDF Download ufc_3_310_05a_2005.pdf
UFC 3-310-07A Cold-Formed Load Bearing Steel Systems and Masonry Veneer/Steel Stud Walls, Replaced by UFC 3-301-01   PDF Download ufc_3_310_07a_2006.pdf
UFC 3-310-08 Non-Expeditionary Bridge Inspection, Maintenance and Repair   PDF Download ufc_3_310_08_2018.pdf CCR  
UFC 3-320-01A Welding -- Design Procedures and Inspections, Replaced by UFC 3-301-01   PDF Download ufc_3_320_01a_2005.pdf
UFC 3-320-02A Design and Construction of Conventionally Reinforced Ribbed Mat Slabs (RRMS), Replaced by UFC 3-301-01   PDF Download ufc_3_320_02a_2005.pdf
UFC 3-320-03A Structural Considerations for Metal Roofing, with Change 2, Replaced by UFC 3-110-03   PDF Download ufc_3_320_03a_2005_c2.pdf
UFC 3-320-04A Metal Building Systems, with Change 2, Replaced by UFC 3-301-01   PDF Download ufc_3_320_04a_c2.pdf
UFC 3-320-05A Structural Design Criteria for Structures Other Than Buildings, Replaced by UFC 3-301-01   PDF Download ufc_3_320_05a_2005.pdf
UFC 3-320-06A Concrete Floor Slabs on Grade Subjected to Heavy Loads   PDF Download ufc_3_320_06a_2005.pdf
UFC 3-330-01A Commentary on Snow Loads, Replaced by UFC 3-301-01   PDF Download ufc_3_330_01a_2005.pdf
UFC 3-330-02A Commentary On Roofing Systems, Replaced by UFC 3-110-03   PDF Download ufc_3_330_02a_2005.pdf
UFC 3-330-03A Seismic Review Procedures for Existing Military Buildings, Replaced by UFC 3-310-04   PDF Download ufc_3_330_03a._2005.pdf
UFC 3-340-01 Design and Analysis of Hardened Structures to Conventional Weapons Effects (FOUO)   PDF Download ufc_3_340_01_2002.pdf CCR  
UFC 3-340-02 Structures to Resist the Effects of Accidental Explosions, with Change 2   PDF Download ufc_3_340_02_2008_c2.pdf CCR