UFC documents provide planning, design, construction, sustainment, restoration, and modernization criteria, and apply to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with DoD Directive 4270.5 (Military Construction) and USD(AT&L) Memorandum dated 29 May 2002. UFC are distributed only in electronic media and are effective upon issuance.

The United States Army Corps of Engineers (HQUSACE), Naval Facilities Engineering Systems Command (NAVFAC), and the Air Force Civil Engineer Center (AFCEC) are responsible for administration of the UFC system. Points of contact and procedures for the development and maintenance UFC documents are prescribed in the latest edition of MIL-STD-3007.

UFCs that have been unified for use by all participating agencies have no alphabetical letter at the end of the document number. UFCs that are agency-specific have an alphabetical letter (or letters) at the end of the document. A document that has a letter "A" indicates USACE, an "N" indicates NAVFAC and an "F" indicates AFCEC. A combination of two letters indicates that the document is used by two agencies.

Facilities Criteria (FC) DESIGNATION

The "Facilities Criteria (FC)" designation has been adopted for criteria that are not applicable to all DoD Components. This is specific to facility-type documents only, for example, FC 4-721-10N "Navy and Marine Corps Unaccompanied Housing". Facilities Criteria (FC) provide functional requirements (i.e., defined by users and operational needs of a particular facility type). Differences in functional requirements between DoD Components may exist due to differences in policies and operational needs. FC are applicable only to the DoD Component(s) indicated in the title, and are intended for use with unified technical requirements published in DoD Unified Facilities Criteria (UFC).

UFC Template in MS Word  (05-06-2025: updated REFERENCES and COMMENTARY paragraphs to align with UFC 1-300-01, Change 1)

Questions, comments, suggestions and recommended changes for these documents are welcome and should be submitted as a Criteria Change Request (CCR). To submit a Criteria Change Request, click on the CCR link next to the document below. CCRs are not appropriate when they pertain to a specific project solicitation, request for proposal or after a project award. Questions or interpretations pertaining to these documents or situation should be referred to the Contracting Officer. To view the UFC modification classifications, see the UFC-UFGS Revision-Change Policy .

 Indicates the UFC has an attachment. Click the title to view the attachment under 'Related Materials'.

? Active: Document is current, regularly maintained by the responsible DWG through formal revisions and changes, and must be used in accordance with its applicability paragraphs.

Inactive: Document is not regularly maintained due to limited use. May be used for new projects per applicability paragraphs, but users must verify content relevancy and accept responsibility for using potentially outdated information.

Archived: Document is outdated or superseded and not maintained. Prohibited for use in new projects. Available only for historical reference or for existing projects that previously cited the document before archival.


TITLE Date Change Date View CCR
UFC 3-340-03AN Weapons Effects: Designing Facilities to Resist Nuclear Weapon Effects, Replaced by UFC 3-350-03AN   View/Download  
UFC 3-340-04AN Structures: Designing Facilities to Resist Nuclear Weapon Effects, Replaced by UFC 3-350-04AN   View/Download  
UFC 3-340-05AN Shock Isolation Systems: Designing Facilities to Resist Nuclear Weapon Effects, Replaced by UFC 3-350-05AN   View/Download  
FC 3-340-05AN Shock Isolation Systems: Designing Facilities to Resist Nuclear Weapon Effects, Replaced by UFC 3-350-05AN   View/Download  
UFC 3-340-06AN Air Entrapment, Fasteners, Penetration Protection, Hydraulic-Surge Protection Devices and EMP Protective Devices: Designing Facilities to Resist Nuclear Weapon Effects, Replaced by UFC 3-350-06AN   View/Download  
UFC 3-340-07AN Hardness Verification: Designing Facilities to Resist Nuclear Weapon Effects, Replaced by UFC 3-350-07AN   View/Download  
UFC 3-340-09AN Illustrative Examples: Designing Facilities to Resist Nuclear Weapon Effects, Replaced by UFC 3-350-09AN   View/Download  
UFC 3-340-10AN Facilities System Engineering: Designing Facilities to Resist Nuclear Weapon Effects, Replaced by UFC 3-350-10AN   View/Download  
UFC 3-340-13 Basic Guidelines for Chemical Warfare Hardening of Facilities, Replaced by UFC 4-024-01   View/Download  
UFC 3-350-03AN Weapons Effects: Designing Facilities to Resist Nuclear Weapon Effects, with Change 2, INACTIVE with No Replacement   View/Download  
UFC 3-350-04AN Structures: Designing Facilities to Resist Nuclear Weapon Effects, with Change 2   View/Download  
UFC 3-350-05AN Shock Isolation Systems: Designing Facilities to Resist Nuclear Weapon Effects, INACTIVE with No Replacement   View/Download  
UFC 3-350-05AN Shock Isolation Systems: Designing Facilities to Resist Nuclear Weapon Effects, with Change 2   View/Download  
UFC 3-350-06AN Air Entrapment, Fasteners, Penetration Protection, Hydraulic-Surge Protection Devices and EMP Protective Devices: Designing Facilities to Resist Nuclear Weapon Effects, with Change 2   View/Download  
UFC 3-350-07AN Hardness Verification: Designing Facilities to Resist Nuclear Weapon Effects, with Change 2   View/Download  
UFC 3-350-08AN Facilities Support Systems: Designing Facilities to Resist Nuclear Weapon Effects, with Change 2   View/Download  
UFC 3-350-09AN Illustrative Examples: Designing Facilities to Resist Nuclear Weapon Effects, with Change 2   View/Download  
UFC 3-350-10AN Facilities System Engineering: Designing Facilities to Resist Nuclear Weapon Effects, with Change 1   View/Download  
UFC 3-400-01 Energy Conservation, with Change 4, Replaced by UFC 1-200-02   View/Download  
UFC 3-400-02 Design: Engineering Weather Data, with Change 2   View/Download   CCR  
UFC 3-400-10N Mechanical Engineering, with Change 1, Replaced by UFC 3-410-01   View/Download  
UFC 3-401-01 Mechanical Engineering, with Change 1   View/Download   CCR  
UFC 3-401-01FA Utility Monitoring and Control Systems, Replaced by UFC 3-470-01   View/Download  
FC 3-401-02N Navy and Marine Corps Existing Building Commissioning  , View/Download   CCR  
UFC 3-401-05N Estimating Energy and Water Consumption for Shore Facilities and Cold Iron Support for Ships, Cancelled without Replacement   View/Download  
UFC 3-410-01 Heating, Ventilating, and Air Conditioning Systems, with Change 9  , View/Download   CCR  
UFC 3-410-01FA Heating, Ventilating, and Air Conditioning, with Change 4, Replaced by UFC 3-410-01   View/Download  
UFC 3-410-02 Direct Digital Control for HVAC and Other Building Control Systems, with Change 2  , View/Download   CCR  
UFC 3-410-02A Heating, Ventilating, and Air Conditioning (HVAC) Control Systems, with Change 1, Replaced by UFC 3-410-02   View/Download  
UFC 3-410-02N Heating, Ventilating, Air Conditioning and Dehumidifying Systems, Replaced by UFC 3-400-10N   View/Download  
UFC 3-410-03FA Heating, Ventilating, and Air Conditioning of Hardened Installations, with Change 1, Replaced by UFC 4-024-01   View/Download  
UFC 3-410-04 Industrial Ventilation   View/Download   CCR  
UFC 3-410-04N Design: Industrial Ventilation Systems, Replaced by UFC 3-410-04   View/Download  
UFC 3-410-05N Heating Systems Operation and Maintenance   View/Download  
UFC 3-410-06N Central Heating Plants Operation and Maintenance   View/Download  
UFC 3-420-01 Plumbing Systems   View/Download   CCR  
UFC 3-420-02 Compressed Air   View/Download   CCR  
UFC 3-430-01FA Heating and Cooling Distribution Systems   View/Download   CCR  
UFC 3-430-02FA Central Steam Boiler Plants, with Change 1   View/Download  
UFC 3-430-03 Air Pollution Control Systems for Boiler and Incinerators   View/Download  
UFC 3-430-04FA High Temperature Water Heating Systems   View/Download  
UFC 3-430-05 Natural Gas and Liquefied Petroleum Gas (LPG) Distribution Pipelines   View/Download   CCR  
UFC 3-430-05FA Gas Distribution, Replaced by UFC 3-430-09   View/Download  
UFC 3-430-07 Operations and Maintenance: Inspection and Certification of Boilers and Unfired Pressure Vessels, with Change 5   View/Download  
UFC 3-430-08N Central Heating Plants   View/Download  
UFC 3-430-09 Exterior Mechanical Utility Distribution, with Change 1   View/Download   CCR  
UFC 3-430-09N Exterior Mechanical Utility Distribution, Replaced by UFC 3-430-09   View/Download  
UFC 3-430-11 Boiler Plant Instrumentation and Control Systems   View/Download   CCR  
UFC 3-440-01 Facility-Scale Renewable Energy Systems   View/Download   CCR  
UFC 3-440-02N Water Conservation Operation and Maintenance   View/Download  
UFC 3-440-03N Passive Solar Buildings   View/Download  
UFC 3-440-04N Solar Heating of Buildings and Domestic Hot Water, Replaced by UFC 3-440-01   View/Download  
UFC 3-440-05N Tropical Engineering, with Changes 1-2   View/Download  
UFC 3-440-06N Cooling Buildings by Natural Ventilation   View/Download  
UFC 3-450-01 Noise and Vibration Control   View/Download   CCR  
UFC 3-450-02 Power Plant Acoustics   View/Download  
UFC 3-460-01 Design: Petroleum Fuel Facilities, with Change 3   View/Download   CCR  
UFC 3-460-03 Petroleum Fuel Systems Maintenance, with Change 2   View/Download   CCR  
UFC 3-470-01 Utility Monitoring and Control System (UMCS) Front End and Integration   View/Download   CCR  
UFC 3-490-03FA High-Pressure Gas and Cryogenic Systems   View/Download  
UFC 3-490-04A Indoor Radon Prevention and Mitigation   View/Download  
UFC 3-490-06 Elevators, with Change 1   View/Download   CCR  
UFC 3-501-01 Electrical Engineering   View/Download   CCR  
UFC 3-501-03N Design: Electrical Engineering Preliminary Design Considerations, Replaced by UFC 3-501-01 and UFC 3-550-01   View/Download  
UFC 3-510-01 Foreign Voltages and Frequencies Guide, with Change 2   View/Download   CCR  
UFC 3-520-01 Interior Electrical Systems   View/Download   CCR  
UFC 3-520-02 Facility Energy System Resilience and Reliability, with Change 1   View/Download   CCR  
UFC 3-520-05 Stationary and Mission Batteries, with Change 2   View/Download   CCR  
UFC 3-530-01 Interior and Exterior Lighting Systems, with Change 1   View/Download   CCR  
UFC 3-535-01 Visual Air Navigation Facilities, with Change 4   View/Download   CCR  
UFC 3-535-02 Design Drawings for Visual Air Navigation Facilities  , View/Download   CCR  
UFC 3-540-01 Engine-Driven Generator Systems for Prime and Standby Power Applications, with Change 3   View/Download   CCR  
UFC 3-540-02N Steam Power Plants   View/Download  
UFC 3-540-04N Design: Diesel Electric Generating Plants, Replaced by UFC 3-540-01   View/Download  
UFC 3-540-07 Operation and Maintenance (O&M): Generators, with Change 1   View/Download   CCR  
UFC 3-540-08 Utility-Scale Renewable Energy Systems   View/Download   CCR  
UFC 3-550-01 Exterior Electrical Power Distribution, with Change 3   View/Download   CCR  
UFC 3-550-03FA Design: Electric Power Supply and Distribution, Replaced bY UFC 3-550-01   View/Download  
UFC 3-550-03N Design: Power Distribution Systems, Replaced by UFC 3-550-01   View/Download  
UFC 3-550-04 Resilient Installation Microgrid Design   View/Download   CCR  
UFC 3-550-07 Operation and Maintenance (O&M): Exterior Power Distribution Systems   View/Download   CCR  
UFC 3-555-01 Aircraft Point-of-Use Power Systems   View/Download   CCR  
UFC 3-555-01N 400 Hertz Medium Voltage Conversion/Distribution and Low Voltage Utilization Systems   View/Download  
UFC 3-560-01 Operation and Maintenance: Electrical Safety, with Change 3   View/Download   CCR  
UFC 3-560-10N O&M: Safety of Electrical Transmission and Distribution Systems, Replaced by 3-560-01    View/Download  
UFC 3-570-01 Cathodic Protection, with Change 1   View/Download   CCR  
UFC 3-570-02A Cathodic Protection, Replaced by UFC 3-570-01   View/Download  
UFC 3-570-02N Electrical Engineering Cathodic Protection, Replaced by UFC 3-570-01   View/Download  
UFC 3-570-06 Operation and Maintenance: Cathodic Protection Systems   View/Download   CCR  
UFC 3-575-01 Lightning and Static Electricity Protection Systems, with Change 1   View/Download   CCR  
UFC 3-580-01 Information and Communications Technology Infrastructure Planning and Design  , View/Download   CCR  
UFC 3-580-10 Navy And Marine Corps Intranet (NMCI) Standard Construction Practices, Replaced by UFC 3-580-01   View/Download  
UFC 3-600-01 Fire Protection Engineering for Facilities, with Change 6   View/Download   CCR  
UFC 3-601-02 Fire Protection Systems Inspection, Testing, and Maintenance, with Change 1   View/Download   CCR  
UFC 3-700-01A Design: Programming Cost Estimates for MILCON, Replaced by UFC 3-730-01   View/Download  
UFC 3-700-02A Construction Cost Estimates, Replaced by UFC 3-740-05   View/Download  
UFC 3-701-01 DoD Facilities Pricing Guide, with Change 7  , View/Download   CCR  
UFC 3-710-01A Code 3 Design with Parametric Estimating, Cancelled without Replacement   View/Download  
UFC 3-730-01 Programming Cost Estimates for Military Construction  , View/Download   CCR  
UFC 3-740-05 Construction Cost Estimating  , View/Download   CCR  
UFC 3-810-01N Navy and Marine Corps Environmental Engineering for Facility Construction, with Change 3   View/Download   CCR  
UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings, with Change 3   View/Download   CCR  
UFC 4-010-02 DoD Minimum Antiterrorism Standoff Distances for Buildings (FOUO) Replaced by UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings   View/Download  
UFC 4-010-03 Security Engineering: Physical Security Measures for High-Risk Personnel   View/Download  
UFC 4-010-05 SCIF/SAPF Planning, Design, and Construction   View/Download   CCR  
UFC 4-010-06 Cybersecurity of Facility-Related Control Systems (FRCS)  , View/Download   CCR  
UFC 4-020-01 DoD Security Engineering Facilities Planning Manual   View/Download   CCR  
UFC 4-020-02FA Security Engineering: Concept Design (FOUO)   View/Download  
UFC 4-020-03FA Security Engineering: Final Design (FOUO)   View/Download  
UFC 4-020-04FA Security Engineering: Electronic Security Systems, Replaced by UFC 4-021-02   View/Download  
UFC 4-021-01 Design and O&M: Mass Notification Systems, with Change 1   View/Download   CCR  
UFC 4-021-02 Electronic Security Systems  , View/Download   CCR  
UFC 4-022-01 Security Engineering: Entry Control Facilities / Access Control Points   View/Download   CCR  
UFC 4-022-02 Selection and Application of Vehicle Barriers, with Change 1   View/Download   CCR  
UFC 4-022-03 Security Fences and Gates   View/Download   CCR  
UFC 4-023-03 Design of Buildings to Resist Progressive Collapse, with Change 4   View/Download   CCR  
UFC 4-023-07 Design to Resist Direct Fire Weapons Effects, with Change 1   View/Download   CCR  
UFC 4-023-10 Safe Havens   View/Download   CCR  
UFC 4-024-01 Security Engineering: Procedures for Designing Airborne Chemical, Biological, and Radiological Protection for Buildings   View/Download  
UFC 4-025-01 Security Engineering: Waterfront Security   View/Download   CCR  
UFC 4-026-01 Design to Resist Forced Entry   View/Download   CCR  
UFC 4-027-01 Design of Deployed Operational Bases to Mitigate Terrorist Attacks (CUI)   View/Download  
UFC 4-030-01 Sustainable Development, Replaced by UFC 1-200-02   View/Download  
UFC 4-121-10N Design: Aircraft Fixed Point Utility Systems   View/Download  
UFC 4-133-01 Air Traffic Control and Air Operations Facilities, with Change 2   View/Download   CCR  
UFC 4-133-01N Navy Air Traffic Control Facilities, Replaced by UFC 4-133-01   View/Download  
UFC 4-141-03 Command, Control, Computers, Communications, Cyber-Defense, Intelligence, Surveillance, And Reconnaissance (C5ISR) Facilities   View/Download   CCR  
UFC 4-141-04 Emergency Operations Center Planning and Design, with Change 1   View/Download  
FC 4-141-05N Navy and Marine Corps \1\Facility and Energy Operations Centers/1/, with Change 1   View/Download  
UFC 4-141-10 Airfield Operations Support Facilities   View/Download   CCR  
UFC 4-150-02 Dockside Utilities for Ship Service   View/Download   CCR  
UFC 4-150-06 Military Harbors and Coastal Facilities, with Change 1   View/Download   CCR  
UFC 4-150-07 Maintenance and Operation: Maintenance of Waterfront Facilities, with Change 1   View/Download   CCR  
UFC 4-150-08 Mooring Hardware Inspection   View/Download   CCR  
UFC 4-150-09 Permanent Anchored Moorings Operations and Maintenance   View/Download   CCR  
UFC 4-151-10 General Criteria for Waterfront Construction, with Change 1   View/Download   CCR  
UFC 4-152-01 Piers and Wharves, with Change 1   View/Download   CCR  
UFC 4-152-07 Design: Small Craft Berthing Facilities, with Change 1   View/Download   CCR  
UFC 4-159-01N Design: Hyperbaric Facilities   View/Download  
UFC 4-159-03 Moorings   View/Download   CCR  
UFC 4-171-01N Design: Aviation Training Facilities   View/Download  
UFC 4-171-02A U.S. Army Service Schools   View/Download  
UFC 4-171-05 Army Reserve Facilities, with Change 3   View/Download  
FC 4-171-06N Navy Operational Support Center   View/Download   CCR  
UFC 4-179-01 Design: Navy Firefighting School Facilities   View/Download  
UFC 4-179-02 Small Arms Ranges, with Change 1   View/Download   CCR  
FC 4-179-03F Air Force Indoor Small Arms Firing Range, with Change 2   View/Download   CCR  
UFC 4-211-01 Aircraft Maintenance Hangars, with Change 3  , View/Download   CCR  
UFC 4-211-01N Design: Aircraft Maintenance Hangars: Type I & Type II, Replaced by UFC 4-211-01   View/Download  
UFC 4-211-02 Aircraft Corrosion Control and Paint Facilities   View/Download   CCR