UFGS Master Updated February 12, 2026; Posted February 19, 2026

Unified Facilities Guide Specifications (UFGS) are a joint effort of the U.S. Army Corps of Engineers (USACE), the Naval Facilities Engineering Systems Command (NAVFAC), and the Air Force Civil Engineer Center (HQ AFCEC). UFGS are for use in specifying construction for the military services.

The UFGS are only published in electronic format and are intended to be used with SpecsIntact software; SpecsIntact supports the UFGS format. The UFGS Master complies with UFS 1-300-02.

Updated UFGS are posted quarterly in February, May, August, and November.

UFGS that have been unified for use by all participating agencies have a level 3 or level 4 Section number. The UFGS uses level 5 to identify a single-agency specification. The number "10" is used by USACE, "20" by NAVFAC, and "30" by AFCEC. The order of precedence for selecting UFGS sections for a project is generally:

  1. Regional UFGS if required by the contract or published on WBDG
  2. Single-agency UFGS for whom project is being developed
  3. Unified UFGS
  4. UFGS identified as specific to another DoD Service (for DoD projects only)

Points of contact and procedures for the development and maintenance of UFGS documents are prescribed in the latest edition of MIL-STD-3007.

The UFGS Section Template is now provided in the UFGS Master with each quarterly release and can be found under Tools in the SpecsIntact Explorer.

Questions, comments, suggestions and recommended changes for guide specifications should be submitted as a Criteria Change Request (CCR). To submit, click on the CCR link next to the document title (below). CCRs are not appropriate when they pertain to a specific project solicitation, request for proposal, or after a project award. Questions or interpretations pertaining to these documents or situations should be referred to the Contracting Officer. To view the UFGS modification classifications and examples, see the UFGS Revision-Change PolicyDownload 26_UFGS_chg_rev_policy.pdf.

Active documents are available in the following formats:   SpecsIntact (SEC) in compressed ZIP  |   Adobe Acrobat (PDF)

Archived release files are available in  Adobe Acrobat (PDF) in compressed ZIP

 Indicates the UFGS has an attachment. Click the title to view the attachment under 'Related Materials'.

? Active: Document is current, regularly maintained by the responsible DWG through formal revisions and changes, and must be used in accordance with its applicability paragraphs.

Archived: Document is outdated or superseded and not maintained. Prohibited for use in new projects. Available only for historical reference or for existing projects that previously cited the document before archival.


Title Date Change Date View CCR
UFGS 27 05 13.43 Television Distribution System   PDF Download UFGS%2027%2005%2013.43.pdf ZIP Download UFGS%2027%2005%2013.43.zip CCR  
UFGS 27 05 14.00 10 Cable Television Premises Distribution System  
UFGS 27 05 26 Grounding and Bonding for Communications Systems   PDF Download UFGS 27 05 26.pdf ZIP Download UFGS 27 05 26.zip CCR  
UFGS 27 05 28.36 Cable Trays for Communications Systems  
UFGS 27 05 29.00 10 Protective Distribution System (PDS) for SIPRNET Communication Systems   PDF Download UFGS%2027%2005%2029.00%2010.pdf ZIP Download UFGS%2027%2005%2029.00%2010.zip CCR  
UFGS 27 10 00 Building Telecommunications Cabling System   PDF Download UFGS%2027%2010%2000.pdf ZIP Download UFGS%2027%2010%2000.zip CCR  
UFGS 27 15 19.00 10 Wire Line Data Transmission System  
UFGS 27 21 00.00 20 Intercommunication System  
UFGS 27 21 00.00 40 Intercommunication System  
UFGS 27 21 10.00 10 Fiber Optic Data Transmission System  
UFGS 27 31 00.00 20 Administrative Telephone Equipment, Inside Plant  
UFGS 27 33 30.00 10 Stand-Alone One-Way Radio Control System  
UFGS 27 33 31.00 10 One-Way FM Radio Data Control System  
UFGS 27 41 00 Audio-Visual Systems   PDF Download UFGS%2027%2041%2000.pdf ZIP Download UFGS%2027%2041%2000.zip CCR  
UFGS 27 41 00.00 10 Nurse Call Audio-Visual (NCAV) System  
UFGS 27 41 16.00 10 Television Signal Reception System  
UFGS 27 51 13.00 10 Radio Paging System  
UFGS 27 51 16 Public Address Systems   PDF Download UFGS%2027%2051%2016.pdf ZIP Download UFGS%2027%2051%2016.zip CCR  
UFGS 27 51 23 Intercommunication System   PDF Download UFGS%2027%2051%2023.pdf ZIP Download UFGS%2027%2051%2023.zip CCR  
UFGS 27 51 23.10 Intercommunication System  
UFGS 27 52 23.00 20 Nurse Call System  
UFGS 27 52 24 Nurse Call System   PDF Download UFGS%2027%2052%2024.pdf ZIP Download UFGS%2027%2052%2024.zip CCR  
UFGS 27 52 32.00 10 Nurse Call Tone-Visual (NCTV) System  
UFGS 27 53 19.13 First Responder Distributed Antennae Systems (DAS)   PDF Download UFGS%2027%2053%2019.13.pdf ZIP Download UFGS%2027%2053%2019.13.zip CCR  
UFGS 27 54 00.00 20 Community Antenna Television (CATV)  
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY   ZIP Download UFGS%20DIVISION%2028.zip
UFGS 28 05 26 Grounding and Bonding for Electronic Safety and Security  
UFGS 28 05 26.00 40 Grounding and Bonding For Electronic Safety and Security  
UFGS 28 08 10 Electronic Security System Acceptance Testing   PDF Download UFGS%2028%2008%2010.pdf ZIP Download UFGS%2028%2008%2010.zip CCR  
UFGS 28 10 05 Electronic Security Systems (ESS)   PDF Download UFGS%2028%2010%2005.pdf ZIP Download UFGS%2028%2010%2005.zip CCR  
UFGS 28 16 00.00 20 Basic Intrusion Detection System (IDS)  
UFGS 28 16 01.00 10 Small Intrusion Detection System  
UFGS 28 20 00.00 20 Electronic Security Systems (ESS) Commercial  
UFGS 28 20 01.00 10 Electronic Security System  
UFGS 28 20 02 Central Monitoring Services for Electronic Security Systems   PDF Download UFGS%2028%2020%2002.pdf ZIP Download UFGS%2028%2020%2002.zip CCR  
UFGS 28 23 23.00 10 Closed Circuit Television Systems  
UFGS 28 26 23 Duress Signal System (for Brig Facilities)  
UFGS 28 31 00.00 10 Fire Detection and Alarm System, Direct Current Loop  
UFGS 28 31 02.00 20 Fire Alarm Reporting Systems - Digital Communicators  
UFGS 28 31 32 Fire Alarm Reporting System, Digital Communicator Type   PDF Download UFGS%2028%2031%2032.pdf ZIP Download UFGS%2028%2031%2032.zip CCR  
UFGS 28 31 33 Fire Alarm Reporting System, Radio Type   PDF Download UFGS%2028%2031%2033.pdf ZIP Download UFGS%2028%2031%2033.zip CCR  
UFGS 28 31 33.00 10 Fire Alarm Reporting System, Radio Type  
UFGS 28 31 33.13 20 Exterior Fire Reporting System, Radio Type  
UFGS 28 31 49 Carbon Monoxide Detectors  
UFGS 28 31 53.00 40 Fire Alarm Initiating Devices  
UFGS 28 31 60 Interior Fire Alarm System, Non-Addressable   PDF Download UFGS%2028%2031%2060.pdf ZIP Download UFGS%2028%2031%2060.zip CCR  
UFGS 28 31 63.00 20 Analog/Addressable Interior Fire Alarm System  
UFGS 28 31 64.00 10 Fire Detection and Alarm System, Addressable  
UFGS 28 31 66 Interior Fire Alarm and Mass Notification System, Non-Addressable   PDF Download UFGS%2028%2031%2066.pdf ZIP Download UFGS%2028%2031%2066.zip CCR  
UFGS 28 31 70 Interior Fire Alarm System, Addressable   PDF Download UFGS%2028%2031%2070.pdf ZIP Download UFGS%2028%2031%2070.zip CCR  
UFGS 28 31 73.00 20 Exterior Fire Alarm System, Closed Circuit Telegraphic Type  
UFGS 28 31 74.00 20 Interior Fire Detection and Alarm System  
UFGS 28 31 75.00 10 Central Fire Alarm System, Digital Alarm Communicator Type  
UFGS 28 31 76 Interior Fire Alarm and Mass Notification System, Addressable   PDF Download UFGS%2028%2031%2076.pdf ZIP Download UFGS%2028%2031%2076.zip CCR  
UFGS 28 40 01 Watchtour System (for Brig Facilities)  
DIVISION 31 - EARTHWORK   ZIP Download UFGS%20DIVISION%2031.zip
UFGS 31 00 00 Earthwork   PDF Download UFGS%2031%2000%2000.pdf ZIP Download UFGS%2031%2000%2000.zip CCR  
UFGS 31 00 00.00 40 Earthwork  
UFGS 31 05 19 Geotextile  
UFGS 31 05 19.13 Geotextiles for Earthwork   PDF Download UFGS%2031%2005%2019.13.pdf ZIP Download UFGS%2031%2005%2019.13.zip CCR  
UFGS 31 05 20 Geosynthetic Drainage Layer  
UFGS 31 05 21 Geogrid Soil Reinforcement  
UFGS 31 05 22 Geotextiles Used as Filters  
UFGS 31 10 00 Site Clearing   PDF Download UFGS%2031%2010%2000.pdf ZIP Download UFGS%2031%2010%2000.zip CCR  
UFGS 31 11 00 Clearing and Grubbing   PDF Download UFGS%2031%2011%2000.pdf ZIP Download UFGS%2031%2011%2000.zip CCR  
UFGS 31 21 00 Off-Gassing Mitigation   PDF Download UFGS%2031%2021%2000.pdf ZIP Download UFGS%2031%2021%2000.zip CCR  
UFGS 31 21 13 Radon Mitigation   PDF Download UFGS%2031%2021%2013.pdf ZIP Download UFGS%2031%2021%2013.zip CCR  
UFGS 31 23 00.00 20 Excavation and Fill  
UFGS 31 23 00.00 Tunnel Excavation – Blasting   PDF Download UFGS%2031%2023%2000.00.pdf ZIP Download UFGS%2031%2023%2000.00.zip CCR  
UFGS 31 23 01 Underwater Blasting   PDF Download UFGS%2031%2023%2001.pdf ZIP Download UFGS%2031%2023%2001.zip CCR  
UFGS 31 23 06.00 Blasting - Surface   PDF Download UFGS%2031%2023%2006.00.pdf ZIP Download UFGS%2031%2023%2006.00.zip CCR  
UFGS 31 31 16 Soil Treatment for Subterranean Termite Control  
UFGS 31 31 16.13 Chemical Termite Control   PDF Download UFGS%2031%2031%2016.13.pdf ZIP Download UFGS%2031%2031%2016.13.zip CCR  
UFGS 31 31 16.19 Termite Control Barriers   PDF Download UFGS%2031%2031%2016.19.pdf ZIP Download UFGS%2031%2031%2016.19.zip CCR  
UFGS 31 31 16.20 Basaltic Termite Barrier  
UFGS 31 31 16.21 Mesh Termite Barrier  
UFGS 31 32 11 Soil Surface Erosion Control  
UFGS 31 32 19.13 Geogrid Soil Stabilization   PDF Download UFGS%2031%2032%2019.13.pdf ZIP Download UFGS%2031%2032%2019.13.zip CCR  
UFGS 31 32 19.16 Geotextile Soil Stabilization   PDF Download UFGS%2031%2032%2019.16.pdf ZIP Download UFGS%2031%2032%2019.16.zip CCR  
UFGS 31 32 23 Foundation Drilling and Grouting  
UFGS 31 32 39 Bioengineering Practices for Stream Bank and Shoreline Stabilization   PDF Download UFGS%2031%2032%2039.pdf ZIP Download UFGS%2031%2032%2039.zip CCR  
UFGS 31 33 10 Foundation Drilling and Grouting in Rock   PDF Download UFGS 31 33 10.pdf ZIP Download UFGS 31 33 10.zip CCR  
UFGS 31 33 20 Void and Permeation Grouting   PDF Download UFGS%2031%2033%2020.pdf ZIP Download UFGS%2031%2033%2020.zip CCR  
UFGS 31 33 30 Limited Mobility Grouting in Soil   PDF Download UFGS%2031%2033%2030.pdf ZIP Download UFGS%2031%2033%2030.zip CCR  
UFGS 31 35 19.13 Geogrid Slope Protection   PDF Download UFGS%2031%2035%2019.13.pdf ZIP Download UFGS%2031%2035%2019.13.zip CCR  
UFGS 31 36 00 Gabions   PDF Download UFGS%2031%2036%2000.pdf ZIP Download UFGS%2031%2036%2000.zip CCR  
UFGS 31 41 16 Metal Sheet Piling   PDF Download UFGS%2031%2041%2016.pdf ZIP Download UFGS%2031%2041%2016.zip CCR  
UFGS 31 41 16.16 Synthetic Sheet Piling   PDF Download UFGS%2031%2041%2016.16.pdf ZIP Download UFGS%2031%2041%2016.16.zip CCR  
UFGS 31 43 13.13 Concrete Pressure Grouting   PDF Download UFGS%2031%2043%2013.13.pdf ZIP Download UFGS%2031%2043%2013.13.zip CCR  
UFGS 31 56 13.13 Soil-Bentonite Slurry Walls   PDF Download UFGS%2031%2056%2013.13.pdf ZIP Download UFGS%2031%2056%2013.13.zip CCR  
UFGS 31 60 00 Foundation Preparation  
UFGS 31 62 13.13 Cast-In-Place Concrete Piles   PDF Download UFGS%2031%2062%2013.13.pdf ZIP Download UFGS%2031%2062%2013.13.zip CCR  
UFGS 31 62 13.20 Precast/Prestressed Concrete Piles   PDF Download UFGS%2031%2062%2013.20.pdf ZIP Download UFGS%2031%2062%2013.20.zip CCR  
UFGS 31 62 13.24 Concrete Cylinder Piles   PDF Download UFGS%2031%2062%2013.24.pdf ZIP Download UFGS%2031%2062%2013.24.zip CCR  
UFGS 31 62 13.26 Pressure-Injected Footings   PDF Download UFGS%2031%2062%2013.26.pdf ZIP Download UFGS%2031%2062%2013.26.zip CCR  
UFGS 31 62 16.00 10 Steel H-Piles  
UFGS 31 62 16.13 Steel Pipe Piles   PDF Download UFGS%2031%2062%2016.13.pdf ZIP Download UFGS%2031%2062%2016.13.zip CCR  
UFGS 31 62 16.16 Steel H-Piles   PDF Download UFGS%2031%2062%2016.16.pdf ZIP Download UFGS%2031%2062%2016.16.zip CCR  
UFGS 31 62 19 Timber Piles   PDF Download UFGS%2031%2062%2019.pdf ZIP Download UFGS%2031%2062%2019.zip CCR  
UFGS 31 62 19.00 20 Timber Piles  
UFGS 31 62 19.00 40 Timber Piles  
UFGS 31 62 19.13 Timber Marine Piles   PDF Download UFGS%2031%2062%2019.13.pdf ZIP Download UFGS%2031%2062%2019.13.zip CCR  
UFGS 31 62 20.00 10 Round Timber Piles  
UFGS 31 62 21 Piling: Composite, Wood and Cast In-Place Concrete  
UFGS 31 62 23 Piling: Composite, Wood And Cast In-Place Concrete   PDF Download UFGS%2031%2062%2023.pdf ZIP Download UFGS%2031%2062%2023.zip CCR  
UFGS 31 62 23.13 Concrete-Filled Steel Piles   PDF Download UFGS%2031%2062%2023.13.pdf ZIP Download UFGS%2031%2062%2023.13.zip CCR  
UFGS 31 62 50 Densified Aggregate Piers   PDF Download UFGS%2031%2062%2050.pdf ZIP Download UFGS%2031%2062%2050.zip CCR  
UFGS 31 63 16 Augered Cast-In-Place Piles   PDF Download UFGS%2031%2063%2016.pdf ZIP Download UFGS%2031%2063%2016.zip CCR  
UFGS 31 63 26 Drilled Caissons   PDF Download UFGS%2031%2063%2026.pdf ZIP Download UFGS%2031%2063%2026.zip CCR  
UFGS 31 63 26.00 10 Drilled Foundation Caissons (Piers)  
UFGS 31 63 26.16 20 Drilled Foundation Caissons  
UFGS 31 63 26.60 [Grouted] Helical Piles   PDF Download UFGS%2031%2063%2026.60.pdf ZIP Download UFGS%2031%2063%2026.60.zip CCR  
UFGS 31 63 29 Drilled Concrete Piers and Shafts   PDF Download UFGS%2031%2063%2029.pdf ZIP Download UFGS%2031%2063%2029.zip CCR  
UFGS 31 66 10 Rock Foundation Preparation   PDF Download UFGS%2031%2066%2010.pdf ZIP Download UFGS%2031%2066%2010.zip CCR  
UFGS 31 68 13 Soil and Rock Anchors   PDF Download UFGS%2031%2068%2013.pdf ZIP Download UFGS%2031%2068%2013.zip CCR  
UFGS 31 71 19 Tunnel and Shaft Excavation in Rock - Mechanical   PDF Download UFGS%2031%2071%2019.pdf ZIP Download UFGS%2031%2071%2019.zip CCR  
UFGS 31 73 00 Tunnel and Shaft Grouting  
UFGS 31 73 19 Tunnel and Shaft Grouting   PDF Download UFGS%2031%2073%2019.pdf ZIP Download UFGS%2031%2073%2019.zip CCR  
DIVISION 32 - EXTERIOR IMPROVEMENTS   ZIP Download UFGS%20DIVISION%2032.zip
UFGS 32 01 11.51 Rubber and Paint Removal From Airfield Pavements   PDF Download UFGS%2032%2001%2011.51.pdf ZIP Download UFGS%2032%2001%2011.51.zip CCR  
UFGS 32 01 11.52 Runway Rubber Removal  
UFGS 32 01 13 Bituminous Seal and Fog Coats  
UFGS 32 01 13.00 20 Emulsified Asphalt Seal Coats [with] [without] Aggregate  
UFGS 32 01 13.62 Bituminous Surface Treatment [and] [Sand Seal]   PDF Download UFGS%2032%2001%2013.62.pdf ZIP Download UFGS%2032%2001%2013.62.zip CCR  
UFGS 32 01 13.63 Gilsonite Modified Asphalt Emulsion Seal Coats   PDF Download UFGS%2032%2001%2013.63.pdf ZIP Download UFGS%2032%2001%2013.63.zip CCR  
UFGS 32 01 13.64 Rejuvenation of Asphalt Pavement Surfaces   PDF Download UFGS%2032%2001%2013.64.pdf ZIP Download UFGS%2032%2001%2013.64.zip CCR  
UFGS 32 01 16.17 Cold Milling of Bituminous Pavements  
UFGS 32 01 16.70 Cold-Mix Reused Asphalt Paving   PDF Download UFGS%2032%2001%2016.70.pdf ZIP Download UFGS%2032%2001%2016.70.zip CCR  
UFGS 32 01 16.71 Cold Milling Asphalt Paving   PDF Download UFGS%2032%2001%2016.71.pdf ZIP Download UFGS%2032%2001%2016.71.zip CCR  
UFGS 32 01 16.74 In Place Hot Reused Asphalt Paving   PDF Download UFGS%2032%2001%2016.74.pdf ZIP Download UFGS%2032%2001%2016.74.zip CCR  
UFGS 32 01 16.75 Heater Scarifying of Asphalt Paving   PDF Download UFGS%2032%2001%2016.75.pdf ZIP Download UFGS%2032%2001%2016.75.zip CCR  
UFGS 32 01 17 Cold-Mix Recycling  
UFGS 32 01 17.16 Sealing of Cracks in Bituminous Pavements  
UFGS 32 01 17.61 Sealing Cracks in Asphalt Paving   PDF Download UFGS%2032%2001%2017.61.pdf ZIP Download UFGS%2032%2001%2017.61.zip CCR  
UFGS 32 01 17.62 Paving Fabric Interlayer   PDF Download UFGS%2032%2001%2017.62.pdf ZIP Download UFGS%2032%2001%2017.62.zip CCR  
UFGS 32 01 18.71 Grooving of Airfield Paving   PDF Download UFGS%2032%2001%2018.71.pdf ZIP Download UFGS%2032%2001%2018.71.zip CCR  
UFGS 32 01 19 Field Molded Sealants for Sealing Joints in Rigid Pavements  
UFGS 32 01 19.61 Sealing of Joints in Rigid Pavement   PDF Download UFGS%2032%2001%2019.61.pdf ZIP Download UFGS%2032%2001%2019.61.zip CCR  
UFGS 32 01 22 Bituminous Rejuvenation  
UFGS 32 01 24 Hot In-Place Recycling of Bituminous Pavements  
UFGS 32 01 25 Heater Scarifying of Bituminous Pavements  
UFGS 32 01 26.71 Grooving for Airfield Pavements  
UFGS 32 01 28 Partial-Depth Patching of Rigid Pavements  
UFGS 32 01 29.61 Partial Depth Patching of Rigid Paving   PDF Download UFGS%2032%2001%2029.61.pdf ZIP Download UFGS%2032%2001%2029.61.zip CCR  
UFGS 32 01 29.62 Concrete Pavement Raising   PDF Download UFGS%2032%2001%2029.62.pdf ZIP Download UFGS%2032%2001%2029.62.zip CCR  
UFGS 32 05 33 Landscape Establishment   PDF Download UFGS%2032%2005%2033.pdf ZIP Download UFGS%2032%2005%2033.zip CCR  
UFGS 32 10 00 [Pervious] Bituminous Concrete Pavement  
UFGS 32 11 10 Drainage Layer  
UFGS 32 11 13.13 Lime Treated Subgrade   PDF Download UFGS%2032%2011%2013.13.pdf ZIP Download UFGS%2032%2011%2013.13.zip CCR  
UFGS 32 11 13.16 Bituminous-Stabilized Subgrade   PDF Download UFGS%2032%2011%2013.16.pdf ZIP Download UFGS%2032%2011%2013.16.zip CCR