UFGS Master Updated May 19, 2025; Posted May 29, 2025

Unified Facilities Guide Specifications (UFGS) are a joint effort of the U.S. Army Corps of Engineers (USACE), the Naval Facilities Engineering Systems Command (NAVFAC), and the Air Force Civil Engineer Center (HQ AFCEC). UFGS are for use in specifying construction for the military services.

The UFGS are only published in electronic format and are intended to be used with SpecsIntact software; SpecsIntact supports the UFGS format. The UFGS Master complies with UFC 1-300-02.

Questions, comments, suggestions and recommended changes for guide specifications should be submitted as a Criteria Change Request (CCR). To submit, click on the CCR link next to the document title (below). CCRs are not appropriate when they pertain to a specific project solicitation, request for proposal, or after a project award. Questions or interpretations pertaining to these documents or situations should be referred to the Contracting Officer. To view the UFGS modification classifications and examples, see the UFGS Revision-Change Policy .

Active documents are available in the following formats:   SpecsIntact (SEC) in compressed ZIP  |   Adobe Acrobat (PDF)

Archived release files are available in  Adobe Acrobat (PDF) in compressed ZIP

  Indicates the UFGS has an attachment. Click the title to view the attachment under 'Related Materials'.

? Active: Document is current, regularly maintained by the responsible DWG through formal revisions and changes, and must be used in accordance with its applicability paragraphs.

Archived: Document is outdated or superseded and not maintained. Prohibited for use in new projects. Available only for historical reference or for existing projects that previously cited the document before archival.


Title Date View CCR
UFGS 01 42 00 Sources for Reference Publications   View/Download  |View/Download   CCR  
UFGS 01 42 15 Metric Measurements   View/Download  |View/Download   CCR  
UFGS 01 45 00 Quality Control   View/Download  |View/Download   CCR  
UFGS 01 45 00.00 10 Quality Control  
UFGS 01 45 00.00 20 Quality Control  
UFGS 01 45 00.10 10 Quality Control System (QCS)  
UFGS 01 45 00.10 20 Quality Control for Minor Construction  
UFGS 01 45 00.15 10 Resident Management System Contractor Mode (RMS CM)   View/Download  |View/Download   CCR  
UFGS 01 45 01 USACE Quality Control  
UFGS 01 45 01.00 20 Quality Control (QC) - Minor Construction  
UFGS 01 45 01.10 USACE Quality Control System (QCS)  
UFGS 01 45 02 NAVFAC Quality Control  
UFGS 01 45 02.00 10 Quality Control System (QCS)  
UFGS 01 45 02.10 NAVFAC Quality Control for Minor Construction  
UFGS 01 45 04 NASA Quality Control  
UFGS 01 45 04.00 10 Contractor Quality Control  
UFGS 01 45 35 Special Inspections   View/Download  |View/Download   CCR  
UFGS 01 50 00 Temporary Construction Facilities and Controls   View/Download  |View/Download   CCR  
UFGS 01 50 00.00 20 Temporary Facilities and Controls  
UFGS 01 50 00.00 40 Temporary Facilities and Controls  
UFGS 01 50 02.00 10 Temporary Construction Facilities  
UFGS 01 57 16 Temporary Pest Control  
UFGS 01 57 19 Temporary Environmental Controls   View/Download  |View/Download   CCR  
UFGS 01 57 19.00 20 Temporary Environmental Controls  
UFGS 01 57 19.01 20 Supplemental Temporary Environmental Controls  
UFGS 01 57 19.01 Temporary Environmental Controls (GITMO)  
UFGS 01 57 19.02 Temporary Environmental Controls (GTMO)  
UFGS 01 57 20.00 10 Environmental Protection  
UFGS 01 57 23 Temporary Storm Water Pollution Control  
UFGS 01 57 23.00 10 Storm Water Pollution Prevention Measures  
UFGS 01 58 00 Project Identification   View/Download  |View/Download   CCR  
UFGS 01 60 00.00 40 Product Requirements  
UFGS 01 62 35 Recycled / Recovered / Biobased Materials  
UFGS 01 73 19 Installation of Government-Furnished Medical Equipment  
UFGS 01 74 19 Construction Waste Management and Disposal   View/Download  |View/Download   CCR  
UFGS 01 75 00 Starting and Adjusting  
UFGS 01 75 00.00 40 Starting and Adjusting  
UFGS 01 77 00.00 20 Closeout Procedures  
UFGS 01 78 00 Closeout Submittals   View/Download  |View/Download   CCR  
UFGS 01 78 00.00 40 Closeout Submittals  
UFGS 01 78 02.00 10 Closeout Submittals  
UFGS 01 78 23 Operation and Maintenance Data   View/Download  |View/Download   CCR  
UFGS 01 78 23.33 Operation and Maintenance Manuals for Aviation Fuel Systems   View/Download  |View/Download   CCR  
UFGS 01 78 24.00 10 Facility Data Requirements   View/Download  |View/Download   CCR  
UFGS 01 78 24.00 20 Facility Data Workbook (FDW)   View/Download  |View/Download   CCR  
UFGS 01 91 00 Commissioning  
UFGS 01 91 00.00 40 Commissioning  
UFGS 01 91 00.15 10 Total Building Commissioning  
UFGS 01 91 00.15 20 Total Building Commissioning  
UFGS 01 91 00.15 Building Commissioning   View/Download  |View/Download   CCR  
UFGS 01 91 19 Building Enclosure Commissioning   View/Download  |View/Download   CCR  
DIVISION 02 - EXISTING CONDITIONS   ZIP  
UFGS 02 01 50 Operation, Maintenance and Process Monitoring for Soil Vapor Extraction (SVE) Systems  
UFGS 02 32 00 Subsurface Drilling, Sampling, and Testing   CCR  
UFGS 02 32 13 Subsurface Drilling and Sampling   View/Download  |View/Download   CCR  
UFGS 02 35 27 Soil-Bentonite (S-B) Slurry Trench  
UFGS 02 41 00 [Demolition] [and] [Deconstruction]   View/Download  |View/Download   CCR  
UFGS 02 41 00.00 40 Demolition  
UFGS 02 42 00 Construction and Demolition Waste Management  
UFGS 02 42 51 Carpet Removal and Reclamation   View/Download  |View/Download   CCR  
UFGS 02 42 91 Removal and Salvage of Historic Construction Materials   View/Download  |View/Download   CCR  
UFGS 02 51 13 Precipitation/Coagulation/Flocculation Water Treatment   CCR  
UFGS 02 51 19 Solidification and Stabilization Decontamination   View/Download  |View/Download   CCR  
UFGS 02 53 13 Remediation of Contaminated Soils and Sludges by Incineration  
UFGS 02 53 16 Remediation of Contaminated Soils By Thermal Desorption  
UFGS 02 53 16.13 Remediation of Contaminated Soils by Thermal Desorption   View/Download  |View/Download   CCR  
UFGS 02 53 16.16 In-Situ Thermal Remediation   View/Download  |View/Download   CCR  
UFGS 02 54 19.13 Bioremediation Using Landfarming   View/Download  |View/Download   CCR  
UFGS 02 54 19.16 Bioremediation of Soils Using Windrow Composting   View/Download  |View/Download   CCR  
UFGS 02 54 20 Bioremediation of Soils Using Landfarming Systems  
UFGS 02 54 21 Bioremediation of Soils Using Windrow Composting  
UFGS 02 54 23 Soil Washing Through Separation/Solubilization   View/Download  |View/Download   CCR  
UFGS 02 55 00 Solidification/Stabilization (S/S) of Contaminated Material  
UFGS 02 56 13 Waste Containment Geomembrane  
UFGS 02 56 13.13 Geomembrane Waste Containment   View/Download  |View/Download   CCR  
UFGS 02 56 13.16 Clay Waste Containment   View/Download  |View/Download   CCR  
UFGS 02 56 13.19 Geosynthetic Clay Liner Waste Containment   View/Download  |View/Download   CCR  
UFGS 02 56 14 Clay Barrier Layer  
UFGS 02 56 15 Geosynthetic Clay Liner (GCL)  
UFGS 02 61 13 Excavation and Handling of Contaminated Material   View/Download  |View/Download   CCR  
UFGS 02 61 23 Removal and Disposal of PCB Contaminated Soils   View/Download  |View/Download   CCR  
UFGS 02 62 13.00 10 Air and Steam Stripping   View/Download  |View/Download   CCR  
UFGS 02 62 16 Commissioning and Demonstration for Soil Vapor Extraction (SVE) Systems  
UFGS 02 62 16.13 10 Operation, Maintenance and Process Monitoring for Soil Vapor Extraction (SVE) Systems   View/Download  |View/Download   CCR  
UFGS 02 62 16.16 10 Commissioning and Demonstration for Soil Vapor Extraction (SVE) Systems   View/Download  |View/Download   CCR  
UFGS 02 65 00 Underground Storage Tank Removal   View/Download  |View/Download   CCR  
UFGS 02 65 00.00 20 Underground Storage Tank Removal  
UFGS 02 65 01.00 10 Underground Storage Tank Removal  
UFGS 02 66 00 Select Fill and Topsoil for Landfill Cover  
UFGS 02 66 10 Test Fill  
UFGS 02 66 13 Select Fill and Topsoil for Landfill Cover   View/Download  |View/Download   CCR  
UFGS 02 66 16 Test Fill   View/Download  |  ZIP CCR  
UFGS 02 72 13.13 Point of Entry Treatment for Drinking Water   View/Download  |View/Download   CCR  
UFGS 02 81 00 Transportation and Disposal of Hazardous Materials   View/Download  |View/Download   CCR  
UFGS 02 82 00 Asbestos Remediation   View/Download  |View/Download   CCR  
UFGS 02 82 13.00 10 Asbestos Abatement  
UFGS 02 82 14.00 10 Asbestos Hazard Control Activities  
UFGS 02 82 16.00 20 Engineering Control of Asbestos Containing Materials  
UFGS 02 82 33.13 20 Removal/Control and Disposal of Paint with Lead  
UFGS 02 83 00 Lead Remediation   View/Download  |View/Download   CCR  
UFGS 02 83 13.00 20 Lead in Construction  
UFGS 02 83 19.00 10 Lead Based Paint Hazard Abatement, Target Housing and Child Occupied Facilities  
UFGS 02 83 19.13 10 Lead-Based Paint Abatement  
UFGS 02 84 16 Handling of Lighting Ballasts and Lamps Containing PCBs and Mercury   View/Download  |View/Download   CCR  
UFGS 02 84 33 Removal and Disposal of Polychlorinated Biphenyls (PCBs)   View/Download  |View/Download   CCR  
UFGS 02 85 00 Mold Remediation   View/Download  |View/Download   CCR  
UFGS 02 85 00.00 20 Mold Remediation  
DIVISION 03 - CONCRETE   ZIP  
UFGS 03 01 00 Rehabilitation of Concrete   View/Download  |View/Download   CCR  
UFGS 03 01 30 Restoration of Concrete in Historic Structures  
UFGS 03 01 30.71 Concrete Rehabilitation  
UFGS 03 01 32 Concrete Rehabilitation for Civil Works  
UFGS 03 11 13.00 10 Structural Cast-In-Place Concrete Forming  
UFGS 03 11 14.00 10 Formwork for Concrete  
UFGS 03 11 19.00 Insulating Concrete Forming   View/Download  |View/Download   CCR  
UFGS 03 15 00.00 10 Concrete Accessories  
UFGS 03 15 13.00 10 Expansion Joints, Contraction Joints, and Waterstops  
UFGS 03 15 14.00 10 Expansion Contraction and Construction Joints in Concrete for Civil Works  
UFGS 03 20 00.00 10 Concrete Reinforcing  
UFGS 03 20 01.00 10 Concrete Reinforcement  
UFGS 03 20 02 Steel Bars and Welded Wire Fabric for Concrete Reinforcement for Civil Works  
UFGS 03 23 00 Stressed Tendon Reinforcing   View/Download  |View/Download   CCR  
UFGS 03 30 00 Cast-In-Place Concrete   View/Download  |View/Download   CCR  
UFGS 03 30 00.00 10 Cast-In-Place Concrete  
UFGS 03 30 00.00 20 Cast-in-Place Concrete  
UFGS 03 30 00.00 20 Cast-in-Place Concrete  
UFGS 03 30 00.00 40 Cast-in-Place Concrete  
UFGS 03 30 04 Concrete for Minor Structures  
UFGS 03 30 53 Miscellaneous Cast-In-Place Concrete   View/Download  |View/Download   CCR  
UFGS 03 30 53.00 40 Miscellaneous Cast-in-Place Concrete  
UFGS 03 31 00.00 10 Cast-in-Place Structural Concrete  
UFGS 03 31 01.00 10 Cast-In-Place Structural Concrete for Civil Works  
UFGS 03 31 29 Marine Concrete with Service Life Modeling   View/Download  |View/Download   CCR  
UFGS 03 31 30 Marine Concrete   View/Download  |View/Download   CCR  
UFGS 03 33 00 Cast-In-Place Architectural Concrete   View/Download  |View/Download   CCR  
UFGS 03 35 00.00 10 Concrete Finishing  
UFGS 03 37 00 Preplaced-Aggregate Concrete   View/Download  |View/Download   CCR  
UFGS 03 37 13 Shotcrete   View/Download  |View/Download   CCR  
UFGS 03 37 23 Roller-Compacted Concrete for Mass Concrete Construction   View/Download  |View/Download   CCR  
UFGS 03 37 29 Concrete for Concrete Cutoff Walls   View/Download  |View/Download   CCR  
UFGS 03 39 00.00 10 Concrete Curing  
UFGS 03 40 00.00 10 Plant-Precast Concrete Products for Below Grade Construction  
UFGS 03 40 00.00 40 Cast-in-Place Concrete  
UFGS 03 41 16 Precast Concrete Slabs (Max. Span 8'-0" O.C.)  
UFGS 03 41 16.08 Precast Concrete Slabs (MAX. SPAN 8 FEET O.C.)   View/Download  |View/Download   CCR  
UFGS 03 41 33 Precast Structural Pretensioned Concrete   View/Download  |View/Download   CCR  
UFGS 03 41 33.00 10 Precast/Prestressed Concrete Floor and Roof Units  
UFGS 03 41 33.00 40 Precast Structural Pretensioned Concrete  
UFGS 03 41 36.00 10 Precast Roof Decking  
UFGS 03 42 13.00 10 Plant-Precast Concrete Products for Below Grade Construction   View/Download  |View/Download   CCR