Below is a listing of the Revisions and Changes made to UFGS Sections for each release. You can narrow the list by selecting a UFGS Release date from the drop-down and clicking 'Apply'.
| KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA [ARCHIVED] |
|---|---|---|---|---|---|
| ACTION | N New | R Revision | C Change | D Deletion |
| Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
|---|---|---|---|---|---|---|
| Aug-2020 | N | UFGS 08 91 00 Metal [Wall] [and] [Door] Louvers | Aug-2020 | R | This is a periodic revision incorporating updated technical sustainability and corrosion control requirements and responses to CCRs as well as correcting formatting, references, and submittals. | |
| Aug-2020 | N | UFGS 09 67 23.15 Fuel Resistive Resinous Flooring, 3-Coat System | Aug-2010 | C | 2 | In response to CCR 6045, replaced "Vulkem 245" with "Stoneflex MP7" in Table II for Vendor Stonhard's sealant. |
| Aug-2020 | A | UFGS 09 68 00 Carpeting | Nov-2017 | C | 2 | Deleted second paragraph of subpart 2.1.1 in response to CCR 8744. |
| Aug-2020 | N | UFGS 09 90 00 Paints and Coatings | May-2011 | C | 5 | In response to the following CCRs: CCR 3281, corrected metric equivalent measurements in "Existing Surfaces with a Bituminous or Mastic-Type Coating" (3.5.6), "Concrete and Masonry" (3.6.1), and "New[, Existing Uncoated,][ and ][Existing Coated] Plywood and Wood Surfaces, Except Floors" (3.7.1); CCR 4282, added the options of corrosive environments to "Exterior Paint Tables" (3.15.1), EXTERIOR GALVANIZED SURFACES, "G" and "H"; CCR 6392, removed references to SCS Global; CCR 6869, removed "MPI 7" from References and replaced "MPI 7" with "MPI 6" in "Exterior Paint Tables" (3.15.1), Division 6 "A"; and CCR 8722, capitalized "Contractor" throughout. |
| Aug-2020 | N | UFGS 10 22 26.13 Accordion Folding Partitions | Aug-2016 | C | 2 | In response to CCR 8746, "Statement of Code Compliance" and "Statement of Standards Conformity" were removed from SD-07 in the Submittal Article since both are already listed under SD-01. |
| Aug-2020 | N | UFGS 10 22 26.23 Coiling Partitions | Aug-2016 | C | 2 | In response to CCR 8747, "Statement of Code Compliance" and "Statement of Standards Conformity" were removed from SD-07 in the Submittal Article since both are already listed under SD-01. |
| Aug-2020 | N | UFGS 13 34 19 Metal Building Systems | Aug-2020 | R | This is a periodic revision incorporating updated technical sustainability and corrosion control requirements and responses to CCRs as well as correcting formatting, references, and submittals. | |
| Aug-2020 | A | UFGS 13 48 73 Seismic Control For Nonstructural Components | May-2020 | C | 1 | Updated/added UFC reference in second paragraph of subpart 3.6 note and updated last sentence of first text paragraph in response to CCR 8586. |
| Aug-2020 | A | UFGS 21 13 13 Wet Pipe Sprinkler Systems, Fire Protection | Aug-2020 | N | New unified section superseding UFGS 21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION and UFGS 21 13 13.00 20 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION. | |
| Aug-2020 | A | UFGS 21 13 13.00 10 Wet Pipe Sprinkler System, Fire Protection | May-2009 | D | Superseded by UFGS 21 13 13 WET PIPE SPRINKLER SYSTEMS, FIRE PROTECTION. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | N | UFGS 21 13 13.00 20 Wet Pipe Sprinkler System, Fire Protection | Apr-2008 | D | Superseded by UFGS 21 13 13 WET PIPE SPRINKLER SYSTEMS, FIRE PROTECTION Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 21 13 16 Dry Pipe Sprinkler Systems, Fire Protection | Aug-2020 | N | New unified section superseding UFGS 21 13 16.00 20 DRY-PIPE FIRE SPRINKLER SYSTEMS and UFGS 21 13 17.00 10 DRY PIPE SPRINKLER SYSTEM, FIRE PROTECTION. | |
| Aug-2020 | N | UFGS 21 13 16.00 20 Dry-Pipe Fire Sprinkler Systems | Apr-2008 | D | Superseded by UFGS 21 13 16 DRY PIPE SPRINKLER SYSTEMS, FIRE PROTECTION Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 21 13 17.00 10 Dry Pipe Sprinkler System, Fire Protection | May-2009 | D | Superseded by UFGS 21 13 16 DRY PIPE SPRINKLER SYSTEMS, FIRE PROTECTION. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 21 13 18 Preaction Sprinkler Systems, Fire Protection | Aug-2020 | N | New unified section superseding UFGS 21 13 18.00 10 PREACTION AND DELUGE SPRINKLER SYSTEMS, FIRE PROTECTION. | |
| Aug-2020 | A | UFGS 21 13 18.00 10 Preaction and Deluge Sprinkler Systems, Fire Protection | May-2009 | D | Superseded by UFGS 21 13 18 PREACTION SPRINKLER SYSTEMS, FIRE PROTECTION. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 21 13 19 Deluge Sprinkler Systems, Fire Protection | Aug-2020 | N | New unified section superseding UFGS 21 13 19.00 20 [DELUGE] [PREACTION] FIRE SPRINKLER SYSTEMS. | |
| Aug-2020 | N | UFGS 21 13 19.00 20 [Deluge] [Preaction] Fire Sprinkler Systems | Nov-2009 | D | Superseded by UFGS 21 13 19 DELUGE SPRINKLER SYSTEMS, FIRE PROTECTION Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 22 33 30.00 10 Solar Water Heating Equipment | Aug-2020 | R | Complete review and update. | |
| Aug-2020 | A | UFGS 23 05 48.19 Seismic Bracing Mechanical Systems | May-2018 | C | 2 | Added reference to UFC 3-301-02 to various subparts in response to CCR 8761. |
| Aug-2020 | N | UFGS 23 81 00.00 20 Unitary Air Conditioning Equipment | Nov-2009 | D | Superseded by UFGS 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 28 31 00.00 10 Fire Detection and Alarm System, Direct Current Loop | Nov-2008 | D | Superseded by new unified sections: UFGS 28 31 60 INTERIOR FIRE ALARM SYSTEM, NON-ADDRESSABLE; UFGS 28 31 66 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, NON-ADDRESSABLE; UFGS 28 31 70 INTERIOR FIRE ALARM SYSTEM, ADDRESSABLE; and revised UFGS 28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, ADDRESSABLE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | N | UFGS 28 31 49 Carbon Monoxide Detectors | Apr-2006 | D | Superseded by new unified sections: UFGS 28 31 60 INTERIOR FIRE ALARM SYSTEM, NON-ADDRESSABLE; UFGS 28 31 66 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, NON-ADDRESSABLE; UFGS 28 31 70 INTERIOR FIRE ALARM SYSTEM, ADDRESSABLE; and UFGS 28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, ADDRESSABLE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 28 31 60 Interior Fire Alarm System, Non-Addressable | Aug-2020 | N | New unified section replacing/consolidating UFGS 28 31 00.00 10 FIRE DETECTION AND ALARM SYSTEM, DIRECT CURRENT LOOP; UFGS 28 31 49 CARBON MONOXIDE DETECTORS; UFGS 28 31 63.00 20 ANALOG/ADDRESSABLE INTERIOR FIRE ALARM SYSTEM; UFGS 28 31 64.00 10 FIRE DETECTION AND ALARM SYSTEM, ADDRESSABLE; and UFGS 28 31 74.00 20 INTERIOR FIRE DETECTION AND ALARM SYSTEM. | |
| Aug-2020 | N | UFGS 28 31 63.00 20 Analog/Addressable Interior Fire Alarm System | Oct-2007 | D | Superseded by new unified sections: UFGS 28 31 60 INTERIOR FIRE ALARM SYSTEM, NON-ADDRESSABLE; UFGS 28 31 66 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, NON-ADDRESSABLE; UFGS 28 31 70 INTERIOR FIRE ALARM SYSTEM, ADDRESSABLE; and UFGS 28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, ADDRESSABLE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 28 31 64.00 10 Fire Detection and Alarm System, Addressable | Aug-2009 | D | Superseded by new unified sections: UFGS 28 31 60 INTERIOR FIRE ALARM SYSTEM, NON-ADDRESSABLE; UFGS 28 31 66 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, NON-ADDRESSABLE; UFGS 28 31 70 INTERIOR FIRE ALARM SYSTEM, ADDRESSABLE; and UFGS 28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, ADDRESSABLE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 28 31 66 Interior Fire Alarm and Mass Notification System, Non-Addressable | Aug-2020 | N | New unified section replacing/consolidating UFGS 28 31 00.00 10 FIRE DETECTION AND ALARM SYSTEM, DIRECT CURRENT LOOP; UFGS 28 31 49 CARBON MONOXIDE DETECTORS; UFGS 28 31 63.00 20 ANALOG/ADDRESSABLE INTERIOR FIRE ALARM SYSTEM; UFGS 28 31 64.00 10 FIRE DETECTION AND ALARM SYSTEM, ADDRESSABLE; and UFGS 28 31 74.00 20 INTERIOR FIRE DETECTION AND ALARM SYSTEM. | |
| Aug-2020 | A | UFGS 28 31 70 Interior Fire Alarm System, Addressable | Aug-2020 | N | New unified section replacing/consolidating UFGS 28 31 00.00 10 FIRE DETECTION AND ALARM SYSTEM, DIRECT CURRENT LOOP; UFGS 28 31 49 CARBON MONOXIDE DETECTORS; UFGS 28 31 63.00 20 ANALOG/ADDRESSABLE INTERIOR FIRE ALARM SYSTEM; UFGS 28 31 64.00 10 FIRE DETECTION AND ALARM SYSTEM, ADDRESSABLE; and UFGS 28 31 74.00 20 INTERIOR FIRE DETECTION AND ALARM SYSTEM. | |
| Aug-2020 | N | UFGS 28 31 74.00 20 Interior Fire Detection and Alarm System | Feb-2010 | D | Superseded by new unified sections: UFGS 28 31 60 INTERIOR FIRE ALARM SYSTEM, NON-ADDRESSABLE; UFGS 28 31 66 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, NON-ADDRESSABLE; UFGS 28 31 70 INTERIOR FIRE ALARM SYSTEM, ADDRESSABLE; and UFGS 28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, ADDRESSABLE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 28 31 76 Interior Fire Alarm and Mass Notification System, Addressable | Aug-2020 | R | Completely new section replacing/consolidating (previous) UFGS 28 31 74.00 20 INTERIOR FIRE DETECTION AND ALARM SYSTEM and UFGS 28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM, UFGS 28 31 00.00 10 FIRE DETECTION AND ALARM SYSTEM, DIRECT CURRENT LOOP, UFGS 28 31 49 CARBON MONOXIDE DETECTORS, UFGS 28 31 63.00 20 ANALOG/ADDRESSABLE INTERIOR FIRE ALARM SYSTEM, and UFGS 28 31 64.00 10 FIRE DETECTION AND ALARM SYSTEM, ADDRESSABLE. | |
| Aug-2020 | N | UFGS 32 11 33 Cement Stabilized [Base] [Subbase] Course at Airfields and Roads | Aug-2008 | D | Superseded by UFGS 32 11 33.13 PORTLAND CEMENT-STABILIZED BASE COURSES Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2020 | A | UFGS 35 01 41.00 10 Electromechanical Operating Machinery for Locks and Dams | Aug-2020 | R | Complete review and update. | |
| Aug-2020 | A | UFGS 35 05 40.17 Self-Lubricated Materials, Fabrication, Handling, and Assembly | Aug-2020 | R | Complete review and update. | |
| Aug-2020 | A | UFGS 35 20 15 FRP Composites for Low-Head Water Control Structures | Aug-2018 | C | 1 | Deleted third paragraph of subpart 1.8.3 in response to CCR 7032. |
| Aug-2020 | A | UFGS 35 20 23 Dredging | Aug-2020 | R | Complete review and update. PA changed from NAVFAC to USACE. | |
| Aug-2020 | A | UFGS 35 42 34 Reinforced Soil Slope | Aug-2020 | R | Complete review and update. | |
| Aug-2020 | N | UFGS 44 41 00 Water Pollution Containment and Cleanup Equipment | Aug-2020 | N | New Unified Section; Superseding UFGS 44 41 00.00 20 WATER POLLUTION CONTAINMENT AND CLEANUP EQUIPMENT | |
| Aug-2020 | N | UFGS 44 41 00.00 20 Water Pollution Containment and Cleanup Equipment | May-2020 | D | Superseded by unified section UFGS 44 41 00 WATER POLLUTION CONTAINMENT AND CLEANUP EQUIPMENT Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | N | UFGS 00 73 01 Supplementary Conditions for Guantanamo Bay Projects | Aug-2008 | D | Information in this Section is now provided in (Superseded by) UFGS 01 14 00 WORK RESTRICTIONS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | N | UFGS 01 14 00 Work Restrictions | Nov-2011 | C | 9 | Incorporates requirements of UFGS 00 73 01 SUPPLEMENTARY CONDITIONS FOR GUANTANAMO BAY and cancels UFGS 00 73 01; In response to CCR 7820, refinement of electronic security system equipment categories within paragraph Electronic Security Systems Equipment (1.5.1.2.3) |
| May-2020 | N | UFGS 01 30 00 Administrative Requirements | Aug-2015 | C | 3 | In response to CCR 8484, updated paragraph Formal Partnering (1.12.1) to ensure the facilitator is independent of both agencies involved in the project. |
| May-2020 | N | UFGS 01 35 26 Governmental Safety Requirements | Nov-2015 | C | 9 | In response to CCR 6508, administrative changes made in Part 1 and Part 3 to coincide with industry nomenclature. A link to the contractor safety self-evaluation checklist has been added to Contractor Safety Self-Evaluation Checklist (para 1.5). |
| May-2020 | N | UFGS 01 45 00.00 20 Quality Control | Nov-2011 | C | 6 | Added information under QC Manager Duties (1.5.1.1) as well as new paragraph "QC for [Secure Space][Controlled Area][Sound Rated] Perimeter Construction" (1.5.12) to ensure that the government Site Security Manager is involved with the inspection process early on when accreditation is required by ICD/ICS 705 and that the contractor follow a formal process for the inspection and acceptance of secure spaces, controlled areas and sound rated assemblies. Also, in response to the following: CCR 6711, clarified Note in paragraph Laboratory Accreditation Authorities (1.12.2) to include Design Manager (DM); and CCR 6867, updated to ensure duplicate technical commissioning requirements were removed. |
| May-2020 | A | UFGS 01 50 00 Temporary Construction Facilities and Controls | May-2018 | C | 3 | Added cybersecurity requirements during construction, paragraph 1.6, in response to CCR 7450. |
| May-2020 | N | UFGS 01 57 19.01 20 Supplemental Temporary Environmental Controls | Nov-2015 | C | 2 | In response to CCR 8507, Section has been updated to capture the requirements for surplus soil disposal at Camp Lejeune, NC (1.4.6.1.2). |
| May-2020 | N | UFGS 01 73 19 Installation of Government-Furnished Medical Equipment | Apr-2006 | D | Superseded by UFGS 11 70 00 GENERAL REQUIREMENTS FOR MEDICAL AND DENTAL EQUIPMENT. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 01 91 00.15 10 Total Building Commissioning | May-2019 | C | 1 | Updated reference publications in response to CCR 8209. |
| May-2020 | N | UFGS 01 91 00.15 Building Commissioning | Feb-2019 | C | 1 | Preparing Activity changed to NAVFAC as this section has been for Navy-use only since 05-2019; In response to the following: CCR 6881, paragraph Project Schedule (1.6.2) is not appropriate for use on Navy projects and was removed; and CCR 8403, in paragraph Lead Commissioning Specialist (1.8.1) , "ASHRAE Commissioning Process Management Professional (CPMP) was changed to "ASHRAE Building Commissioning Professional (BCxP)" |
| May-2020 | N | UFGS 02 84 16 Handling of Lighting Ballasts and Lamps Containing PCBs and Mercury | May-2020 | R | Complete review and update. | |
| May-2020 | N | UFGS 02 84 33 Removal and Disposal of Polychlorinated Biphenyls (PCBs) | May-2020 | R | Complete review and update. | |
| May-2020 | A | UFGS 08 39 53 Blast Resistant Doors (Earth Covered Magazines) | Feb-2019 | C | 1 | Revised 1st editor's note in response to CCR 7534. |
| May-2020 | N | UFGS 11 70 00 General Requirements for Medical and Dental Equipment | May-2020 | R | Complete review and update; Revision includes merging contents of UFGS 01 73 19 INSTALLATION OF GOVERNMENT-FURNISHED MEDICAL EQUIPMENT into this Section. | |
| May-2020 | A | UFGS 11 71 00 Sterilizers and Associated Equipment | May-2020 | R | Complete review and update including section title change from WARMING CABINETS, STERILIZERS, AND ASSOCIATED EQUIPMENT to STERILIZERS AND ASSOCIATED EQUIPMENT. | |
| May-2020 | N | UFGS 11 72 13 Medical Equipment, Miscellaneous | May-2020 | R | Complete review and update. | |
| May-2020 | N | UFGS 11 74 00 Dental Equipment | May-2020 | R | Complete review and update. | |
| May-2020 | A | UFGS 11 82 19 Packaged Incinerators | May-2020 | N | This UFGS number and title has been reinstated, with Army serving as Preparing Activity; Superseding UFGS 11 82 20 INCINERATORS, GENERAL PURPOSE without revision (nontechnical number and title change) to comply with MF 2011 in response to CCR 1999. | |
| May-2020 | A | UFGS 11 82 20 Incinerators, General Purpose | Aug-2008 | D | Superseded by UFGS 11 82 19 PACKAGED INCINERATORS without revision to comply with MF 2011 in response to CCR 1999. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | N | UFGS 13 17 43 Hydrotherapy Equipment | May-2020 | R | Complete review and update. | |
| May-2020 | A | UFGS 13 48 00 [Seismic ]Bracing for Miscellaneous Equipment | May-2018 | D | Superseded by UFGS 13 48 73 SEISMIC CONTROL FOR MECHANICAL EQUIPMENT without revision to comply with MF 2011 in response to CCR 2006. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 13 48 73 Seismic Control For Nonstructural Components | May-2020 | N | Superseding UFGS 13 48 00 [SEISMIC ]BRACING FOR MISCELLANEOUS EQUIPMENT without revision to comply with MF 2011 in response to CCR 2006. Nontechnical number and title change. | |
| May-2020 | A | UFGS 22 00 70 Plumbing for Healthcare Facilities | May-2020 | R | Complete review and update. | |
| May-2020 | A | UFGS 22 60 70 Gas and Vacuum Systems for Healthcare Facilities | May-2020 | R | Complete review and update. | |
| May-2020 | A | UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems | Aug-2018 | D | Superseded by UFGS 23 30 00 HVAC AIR DISTRIBUTION without revision to comply with MF 2011 in response to CCR 2023. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Feb-2013 | C | 7 | Updated paragraph 2.2.9.2.2 in response to CCR 6151. |
| May-2020 | A | UFGS 23 11 20 Facility Gas Piping | May-2020 | N | Superseding UFGS 23 11 25 FACILITY GAS PIPING without revision to comply with MF 2011 in response to CCR 2027. Nontechnical number change. Updated reference in paragraphs 2.8 and 2.9 in response to CCR 6024. | |
| May-2020 | A | UFGS 23 11 25 Facility Gas Piping | Nov-2008 | D | Superseded by UFGS 23 11 20 FACILITY GAS PIPING without revision to comply with MF 2011 in response to CCR 2027. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 23 30 00 HVAC Air Distribution | May-2020 | N | Superseding UFGS 23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS without revision to comply with MF 2011 in response to CCR 2023. Nontechnical number and title change. Updated test requirements in paragraphs 1.4.5 and 3.13 in response to CCR 7212. Updated paragraph 2.10.5.2.4 in response to CCR 8015. | |
| May-2020 | A | UFGS 23 35 00.00 10 Overhead Vehicle Tailpipe [and Welding Fume] Exhaust Removal System(s) | Feb-2009 | D | Superseded by UFGS 23 35 16.17 10 MECHANICAL ENGINE [AND WELDING FUME] EXHAUST SYSTEMS without revision to comply with MF 2011 in response to CCR 2029. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 23 35 16.17 10 Mechanical Engine [and Welding Fume] Exhaust Systems | May-2020 | N | Superseding UFGS 23 35 00.00 10 OVERHEAD VEHICLE TAILPIPE[ AND WELDING FUME] EXHAUST REMOVAL SYSTEM(S) without revision to comply with MF 2011 in response to CCR 2029. Nontechnical number and title change. | |
| May-2020 | A | UFGS 23 52 30.00 10 Heat Recovery Boilers | May-2020 | N | Superseding UFGS 23 52 43.00 10 HEAT RECOVERY BOILERS without revision to comply with MF 2011 in response to CCR 2031. Nontechnical number change. | |
| May-2020 | A | UFGS 23 52 30.01 10 Central Coal-Fired Steam-Generating System | May-2020 | N | Superseding UFGS 23 70 01.00 10 CENTRAL STEAM-GENERATING SYSTEM, COAL-FIRED without revision to comply with MF 2011 in response to CCR 2034. Nontechnical number and title change. | |
| May-2020 | A | UFGS 23 52 30.02 10 Central Steam Generating System - Combination Gas and Oil Fired | May-2020 | N | Superseding UFGS 23 70 02.00 10 CENTRAL STEAM GENERATING SYSTEM - COMBINATION GAS AND OIL FIRED without revision to comply with MF 2011 in response to CCR 2035. Nontechnical number change. | |
| May-2020 | A | UFGS 23 52 43.00 10 Heat Recovery Boilers | Apr-2008 | D | Superseded by UFGS 23 52 30.00 10 HEAT RECOVERY BOILERS without revision to comply with MF 2011 in response to CCR 2031. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 23 54 16.00 10 Heating System; Gas-Fired Heaters | Apr-2008 | D | Superseded by UFGS 23 80 20.00 10 GAS-FIRED HEATING EQUIPMENT without revision to comply with MF 2011 in response to CCR 2032. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 23 58 00.00 10 Central Steam Heating and Utilities Systems | May-2020 | N | Superseding UFGS 23 70 03.00 10 HEATING AND UTILITIES SYSTEMS, CENTRAL STEAM without revision to comply with MF 2011 in response to CCR 2036. Nontechnical number and title change. | |
| May-2020 | A | UFGS 23 70 01.00 10 Central Steam-Generating System, Coal-Fired | Jan-2008 | D | Superseded by UFGS 23 52 30.01 10 CENTRAL COAL-FIRED STEAM-GENERATING SYSTEM without revision to comply with MF 2011 in response to CCR 2034. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 23 70 02.00 10 Central Steam Generating System - Combination Gas and Oil Fired | Jan-2008 | D | Superseded by UFGS 23 52 30.02 10 CENTRAL STEAM GENERATING SYSTEM - COMBINATION GAS AND OIL FIRED without revision to comply with MF 2011 in response to CCR 2035. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 23 70 03.00 10 Heating and Utilities Systems, Central Steam | Jan-2008 | D | Superseded by UFGS 23 58 00.00 10 CENTRAL STEAM HEATING AND UTILITIES SYSTEMS without revision to comply with MF 2011 in response to CCR 2036. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 23 80 20.00 10 Gas-Fired Heating Equipment | May-2020 | N | Superseding UFGS 23 54 16.00 10 HEATING SYSTEM; GAS-FIRED HEATERS without revision to comply with MF 2011 in response to CCR 2032. Nontechnical number and title change. | |
| May-2020 | N | UFGS 26 00 00.00 20 Basic Electrical Materials and Methods | Jul-2006 | D | Section no longer required - The information in this Section has been incorporated into other UFGS Sections. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | S | UFGS 26 05 13.00 10 Medium-Voltage Cables | May-2020 | R | Performed Tri-Annual Maintenance. CCRs #6382 & 6784 Incorporated | |
| May-2020 | N | UFGS 26 32 13.00 20 Single Operation Generator Sets | Aug-2018 | D | Superseded by UFGS 26 32 15.00 ENGINE-GENERATOR SET STATIONARY 15-2500 KW, WITH AUXILIARIES. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 26 32 14.00 10 Diesel-Generator Set, Stationary 15-300 KW, Standby Applications | Feb-2010 | D | Superseded by UFGS 26 32 15.00 ENGINE-GENERATOR SET STATIONARY 15-2500 KW, WITH AUXILIARIES. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 26 32 15 Engine-Generator Set Stationary 15-2500 kW, with Auxiliaries | May-2020 | N | New Unified UFGS superseding UFGS-26 32 13.00 20 Single Operation Generator Sets, UFGS-26 32 14.00 10 Diesel-Generator Set, Stationary 15-300 kW, Standby Applications, and UFGS-26 32 15.00 10 Diesel-Generator Set, Stationary 100-250 kW, with Auxiliaries | |
| May-2020 | A | UFGS 26 32 15.00 10 Diesel-Generator Set Stationary 100-2500 KW, with Auxiliaries | Oct-2007 | D | Superseded by UFGS 26 32 15.00 ENGINE-GENERATOR SET STATIONARY 15-2500 KW, WITH AUXILIARIES. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 26 36 00.00 10 Automatic Transfer Switch and By-Pass/Isolation Switch | Oct-2007 | D | Superseded by UFGS 26 36 23 AUTOMATIC TRANSFER SWITCHES AND BY-PASS/ISOLATION SWITCH. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 26 36 23 Automatic Transfer Switches and By-Pass/Isolation Switch | May-2020 | N | Superseding UFGS 26 36 00.00 10 AUTOMATIC TRANSFER SWITCHES AND BY-PASS/ISOLATION SWITCH and UFGS 26 36 23.00 20 AUTOMATIC TRANSFER SWITCHES. | |
| May-2020 | N | UFGS 26 36 23.00 20 Automatic Transfer Switches | Apr-2006 | D | Superseded by UFGS 26 36 23 AUTOMATIC TRANSFER SWITCHES AND BY-PASS/ISOLATION SWITCH. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | N | UFGS 26 51 00 Interior Lighting | May-2020 | R | Complete review and update. This includes the Lighting Plates found in both Related Materials and UFGS Forms, Graphics, and Tables. | |
| May-2020 | N | UFGS 26 56 00 Exterior Lighting | May-2020 | R | Complete review and update. This includes the Lighting Plates found in both Related Materials and UFGS Forms, Graphics, and Tables. | |
| May-2020 | S | UFGS 26 56 19.00 40 Roadway Lighting | May-2020 | R | Performed Tri-Annual Maintenance.CCR #4861 Incorporated | |
| May-2020 | S | UFGS 26 56 36.00 40 Flood Lighting | May-2020 | R | Performed Tri-Annual Maintenance. | |
| May-2020 | N | UFGS 27 05 13.43 Television Distribution System | May-2020 | N | New Unified Section superseding UFGS 27 05 14.00 10 CABLE TELEVISION PREMISES DISTRIBUTION SYSTEM, UFGS 27 41 16.00 10 TELEVISION SIGNAL RECEPTION SYSTEM, and UFGS 27 54 00.00 20 COMMUNITY ANTENNA TELEVISION (CATV) SYSTEMS | |
| May-2020 | A | UFGS 27 05 14.00 10 Cable Television Premises Distribution System | Apr-2006 | D | Superseded by UFGS 27 05 13.43 TELEVISION DISTRIBUTION SYSTEM. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | S | UFGS 27 21 10.00 40 Fiber Optic Data Transmission System | May-2020 | R | Performed Tri-Annual Maintenance. | |
| May-2020 | A | UFGS 27 41 16.00 10 Television Signal Reception System | Apr-2006 | D | Superseded by UFGS 27 05 13.43 TELEVISION DISTRIBUTION SYSTEM. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | A | UFGS 27 51 16 Public Address Systems | May-2020 | R | Complete review and update including section title change from RADIO AND PUBLIC ADDRESS SYSTEMS to PUBLIC ADDRESS SYSTEMS. | |
| May-2020 | A | UFGS 27 53 19.13 First Responder Distributed Antennae Systems (DAS) | May-2020 | N | New UFGS. | |
| May-2020 | N | UFGS 27 54 00.00 20 Community Antenna Television (CATV) | Apr-2006 | D | Superseded by UFGS 27 05 13.43 TELEVISION DISTRIBUTION SYSTEM Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2020 | N | UFGS 32 01 17.62 Paving Fabric Interlayer | May-2020 | R | Complete review and update. Section title has been changed from STRESS-ABSORBING MEMBRANE INTERLAYER to PAVING FABRIC INTERLAYER to match the revised content of this section. |