Export to CSV

Below is a listing of the Revisions and Changes made to UFGS Sections for each release. You can narrow the list by selecting a UFGS Release date from the drop-down and clicking 'Apply'.

KEYPREPARING ACTIVITY (PA)A ArmyN NavyF Air ForceS NASA [ARCHIVED]
ACTIONN NewR RevisionC ChangeD Deletion
Release PA UFGS Section Action Change # Nature of Change or Revision
Nov-2014 S UFGS 01 91 00.00 40 Commissioning C 1 Edited PART 1 GENERAL and deleted the mention of Section 01 35 40.00 20; added the listing of Section 01 57 19.00 20 Temporary Environment Controls, and realigned the item lettering.
Nov-2014 A UFGS 03 70 00 Mass Concrete C 1 Replaced section reference 01 35 40.00 20 with 01 57 19.00 20 TEMPORARY ENVIRONMENTAL CONTROLS.
Nov-2014 N UFGS 05 12 00 Structural Steel C 1 Changed Reference A153/A153M to ASTM A123/A123M in Subpart 2.5.
Nov-2014 A UFGS 07 05 23 Pressure Testing an Air Barrier System for Air Tightness C 1 Updated testing requirements in paragraphs 3.4, 3.5 and 3.6.
Nov-2014 N UFGS 09 64 66 Wood Athletic Flooring C 2 Changed Section Reference 31 31 16 Soil Treatment for Subterranean Termite Control to Section Reference 31 31 16.13 Chemical Termite Control
Nov-2014 A UFGS 09 68 00 Carpeting C 2 Added clarification to editor's note as noted in CCR 4007.
Nov-2014 S UFGS 09 96 00 High-Performance Coatings R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 S UFGS 12 31 00 Manufactured Metal Casework R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 S UFGS 12 34 00 Manufactured Plastic Casework R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 S UFGS 12 48 13 Entrance Floor Mats and Frames C 1 Replaced 01 62 35 RECYCLED/RECOVERED/BIOBASED MATERIAL with 01 33 29 SUSTAINABILITY REQUIREMENTS in Subparts 1.2.2 and 1.2.3.
Nov-2014 S UFGS 21 13 00.00 40 Fire-Suppression Sprinkler Systems C 1 Minor change in paragraph 3.3.6
Nov-2014 N UFGS 23 64 10 Water Chillers, Vapor Compression Type C 2 Updated Products Section for chillers in Part 2.
Nov-2014 S UFGS 26 12 19.00 40 Pad-Mounted, Liquid-Filled Medium-Voltage Transformers R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 N UFGS 26 13 00 SF6/High-Firepoint Fluids Insulated Pad-Mounted Switchgear N Superseding UGFS 26 13 00.00 20 SF6/High- Firepoint Fluids Insulated Pad-Mounted Switchgear
Nov-2014 N UFGS 26 13 00.00 20 SF6/High-Firepoint Fluids Insulated Pad-Mounted Switchgear D Superseded by UFGS 26 13 00 with no title change.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 S UFGS 26 23 00.00 40 Switchboards and Switchgear R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 S UFGS 26 24 19.00 40 Motor-Control Centers R Tri-Annual Database Maintenance (TADM) which consists of updating of Section Format, imperative language and formatting review, and verification of all reports and spelling.
Nov-2014 S UFGS 26 24 19.00 40 Motor-Control Centers R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 F UFGS 26 27 13.10 30 Electric Meters C 1 Corrected tagging error in paragraph 2.1.4 e.
Nov-2014 N UFGS 26 32 26 Motor-Generator Sets, 400 Hertz (HZ) D Retired; Section technology is outdated.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 N UFGS 26 35 46.00 20 Radio Frequency Interference Power Line Filters D Out of date, rarely used, can't keep up with technology changes.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 S UFGS 26 41 00.00 40 Lightning Protection System D Redundant; Section replaced by UFGS 26 41 00 Lightning Protection System (Preparing Activity: NAVFAC).
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 S UFGS 26 51 00.00 40 Interior Lighting C 1 Deleted the mention of Section 26 35 46.00 20 RADIO FREQUENCY INTERFERENCE POWER LINE FILTERS from Subpart 2.2.1.8.
Nov-2014 S UFGS 26 55 53 Security Lighting R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 S UFGS 26 56 13.00 40 Lighting Poles and Standards R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 S UFGS 27 13 23.00 40 Communications Optical Backbone Cabling R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 N UFGS 28 26 23 Duress Signal System (for Brig Facilities) D Out of date, rarely used, can't keep up with technology changes.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 N UFGS 28 40 01 Watchtour System (for Brig Facilities) D Out of date, rarely used, can't keep up with technology changes.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 A UFGS 31 31 16 Soil Treatment for Subterranean Termite Control D Section renumbered and renamed to comply with CSI MasterFormat; Superseded by UFGS 31 31 16.13 Chemical Termite Control.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 A UFGS 31 31 16.13 Chemical Termite Control N Superseding UFGS 31 31 16 Soil Treatment for Subterranean Termite Control; Revision of superseded section by Tri-Service Working Group with new number and new title to comply with CSI MasterFormat.
Nov-2014 N UFGS 31 31 16.20 Basaltic Termite Barrier C 2 Corrections to submittals 02, 06, 08, 11. Correction to 3.1 INSTALLATION to install in accordance with manufacturer's installation instruction.
Nov-2014 A UFGS 31 41 16 Metal Sheet Piling C 1 SRF update, changed 00 41 00 BID SCHEDULES to 00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO OFFERORS.
Nov-2014 N UFGS 31 62 13.13 Cast-In-Place Concrete Piles C 1 Changed Section Reference 00 41 00 BID SCHEDULES to Section Reference 00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO OFFERORS.
Nov-2014 N UFGS 31 62 13.20 Precast/Prestressed Concrete Piles C 2 Changed Section Reference 00 41 00 BID SCHEDULES to Section Reference 00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO
OFFERORS.
Nov-2014 N UFGS 31 62 13.24 Concrete Cylinder Piles C 1 Changed Section Reference 00 41 00 BID SCHEDULES to Section Reference 00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO
OFFERORS.
Nov-2014 N UFGS 31 62 16.16 Steel H-Piles C 1 Changed Section Reference 00 41 00 BID SCHEDULES to Section Reference 00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO
OFFERORS.
Nov-2014 N UFGS 31 62 19.13 Timber Marine Piles C 1 Changed Section Reference 00 41 00 BID SCHEDULES to Section Reference 00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO OFFERORS.
Nov-2014 A UFGS 32 01 19 Field Molded Sealants for Sealing Joints in Rigid Pavements C 1 Revised references as noted in CCR 2650.
Nov-2014 A UFGS 32 01 26.71 Grooving for Airfield Pavements C 1 Revised editor's notes as noted in CCR 2611. This revision is also applicable to CCR 3474.
Nov-2014 A UFGS 32 12 15.13 Asphalt Paving for Airfields C 1 Added RAP option to paragraph 2.4.2 as noted in CCR 1481.
Nov-2014 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements C 1 Revised par. 2.2.2.5 as noted in CCR 3847. Revised note in par. 2.4 as noted in CCR 2731.
Nov-2014 A UFGS 32 13 17 Stone Matrix Asphalt (SMA) for Airfield Pavements C 1 Revised references as noted in CCR 3293.
Nov-2014 A UFGS 32 16 13 Concrete Sidewalks and Curbs and Gutters C 1 Added requirements for detectable warning systems as noted in CCR 1754.
Nov-2014 A UFGS 32 16 15 Concrete Block Pavements C 1 Revised references and par. 2.2.1.1 as noted in CCR 3785.
Nov-2014 N UFGS 32 17 23.00 20 Pavement Markings C 2 Qualifications submission moved from SD-03 to SD-07, Add Subparts 1.8 QUALIFICATIONS FOR AIRFILED MARKING and 1.8.1, Airfield Marking Pavement Qualifications
Nov-2014 N UFGS 33 11 00 Water Utility Distribution Piping C 4 Updated Note under Subpart 2.1 Allowable Piping Materials, paragraph 4.
Nov-2014 A UFGS 33 30 00 Sanitary Sewerage C 3 Deleted reference to CID A-A-60005 and revised par. 2.3.4.1 per CCR 2394.
Nov-2014 S UFGS 33 32 13.13 Packaged Sewage Lift Stations, Wet Well Type R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 A UFGS 33 40 00 Stormwater Utilities C 4 Replaced ASTM C 924/C924M with ASTM C969/C969M per CCR 3584.
Nov-2014 A UFGS 33 46 16 Subdrainage Piping C 1 Deleted reference to UFC and updated FAA reference per CCR 2805.
Nov-2014 N UFGS 33 47 13 Pond and Reservoir Liners R Added and updated references in Subpart 1.1 References, added section on warranties (1.5.1), Revised text and deleted table in in Section 2.1.3, revised text in sections 3.7.1 and 3.7.2
Nov-2014 S UFGS 33 71 01.00 40 Overhead Transmission and Distribution R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 N UFGS 33 71 02 Underground Electrical Distribution C 1 Changed Section Reference 31 31 16 SOIL TREATMENT FOR
SUBTERRANEAN TERMITE CONTROL to Section Reference 31 31 16.13 CHEMICAL TERMITE CONTROL
Nov-2014 S UFGS 33 73 00.00 40 Utility Transformers R Tri-Annual Database Maintenance (TADM) which consists of updating of Section Format, imperative language and formatting review, and verification of all reports and spelling.
Nov-2014 S UFGS 33 73 00.00 40 Utility Transformers R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 S UFGS 33 75 00.00 40 Switchgear and Protection Devices R Tri-Annual Database Maintenance (TADM) completed.
Nov-2014 N UFGS 33 81 27 Pier Telephone Distribution Systems D Out of date, rarely used, can't keep up with technology changes.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 A UFGS 34 73 13 Aircraft Tiedowns C 1 Revised paragraphs as noted in CCR 1569.
Nov-2014 A UFGS 35 01 41.00 10 Electromechanical Operating Machinery for Locks and Dams R Revised section to include requirements for locks and dams.
Nov-2014 A UFGS 35 31 19 Stone, Channel, Shoreline/Coastal Protection for Structures C 1 SRF update, changed 00 41 00 BID SCHEDULES to 00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO OFFERORS.
Nov-2014 N UFGS 40 95 33.23 20 Fiber Optic (FO) Outside Plant (OSP) Media D Previously incorporated into UFGS 33 82 00 Telecommunications Outside Plant (OSP).
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 A UFGS 43 31 14 Trickling Filter C 1 Deleted reference and revised par. 2.4.1 and 2.4.2 as noted in CCR 768.
Aug-2014 N UFGS 00 01 15 List of Drawings C 1 Added editor's note to import list of drawings as Excel XML spreadsheet.
Aug-2014 N UFGS 00 41 00 Bid Schedules D Deleted, Superseded by UFGS 00 22 13.00 20 Supplementary Instructions to Offerors through unification.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2014 N UFGS 01 14 00 Work Restrictions C 2 Fixed tailoring and bracket issue throughout. Revised Employment Restrictions for Bremerton, WA
Aug-2014 N UFGS 01 30 00 Administrative Requirements C 2 Deleted 35 mm slides as picture media
Aug-2014 A UFGS 01 50 00 Temporary Construction Facilities and Controls C 1 Moved execution requirements to Part 3 as noted in CCR 3562
Aug-2014 N UFGS 01 78 23 Operation and Maintenance Data C 2 Added editor's note to coordinate with UFGS 01 78 24.00 20 FACILITY eOMSI for Navy projects.
Aug-2014 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) R Added reference note to newly published ECB; changed validation to verification, and deleted manuals from verification process.
Aug-2014 A UFGS 02 41 00 [Demolition] [and] [Deconstruction] C 1 Added FAA requirements as noted in CCR 857
Aug-2014 A UFGS 03 15 00.00 10 Concrete Accessories C 1 Made corrections as noted in CCR 3836
Aug-2014 A UFGS 03 20 00.00 10 Concrete Reinforcing C 1 Corrected spelling as noted in CCR 3841; made corrections as noted in CCR 3842
Aug-2014 N UFGS 07 52 00 Modified Bituminous Membrane Roofing C 2 Fixed typo under "Substrate Preparation. Changed "Don not" to "Do not"
Aug-2014 N UFGS 09 22 00 Supports for Plaster and Gypsum Board C 1 In 2.1 UFC 3-310-04 needed a RID tag; fixed
Aug-2014 N UFGS 13 34 19 Metal Building Systems C 1 Fixed spacing in manufacturers data
Aug-2014 S UFGS 22 14 29.00 Sump Pumps R Tri Annual Database Maintenance (TADM) completed
Aug-2014 A UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems C 3 Added Energy Star requirements
Aug-2014 A UFGS 23 52 00 Heating Boilers C 1 Deleted the mention of Section 00 41 00 BID SCHEDULES, from subpart 1.2.2.1, this section was deleted from the UFGS Database
Aug-2014 S UFGS 23 82 43.00 40 Electric Duct Heaters R Tri Annual Database Maintenance (TADM) completed
Aug-2014 S UFGS 23 82 46.00 40 Electric Unit Heaters R Tri Annual Database Maintenance (TADM) completed
Aug-2014 S UFGS 26 28 21.00 40 Automatic Transfer Switches R Tri Annual Database Maintenance (TADM) completed
Aug-2014 S UFGS 26 52 00.00 40 Emergency Lighting R Tri Annual Database Maintenance (TADM) completed
Aug-2014 S UFGS 27 05 28.36 40 Cable Trays for Communications Systems R Tri Annual Database Maintenance (TADM) completed
Aug-2014 N UFGS 31 31 16.19 Termite Control Barriers R Changes to 3.1, 3.1.1, 3.1.2, 3.2.2, and 3.4; Section Title was changed from TERMITE CONTROL BARRIER SYSTEM to MESH TERMITE CONTROL BARRIER SYSTEM
Aug-2014 N UFGS 31 31 16.20 Basaltic Termite Barrier C 1 Added SDs 6,8, and 11
Aug-2014 A UFGS 31 41 16 Metal Sheet Piling C 1 Deleted the mention of Section 00 41 00 BID SCHEDULES, from subpart 1.2.2.1, this section was deleted from the UFGS Database
Aug-2014 A UFGS 32 32 23 Segmental Concrete Block Retaining Wall C 1 Deleted paragraph as noted in CCR 3331
Aug-2014 N UFGS 32 93 00 Exterior Plants C 1 CCR 3597: ASTM D1527 has been withdrawn with not replacement and CCR 3602: ASTM D1972 has been withdrawn with no replacement
Aug-2014 A UFGS 33 30 00 Sanitary Sewerage C 2 Made corrections as noted in CCR 1672
Aug-2014 A UFGS 33 40 00 Stormwater Utilities C 3 Made change as noted in CCR 3572; added SRPE requirements as noted in CCR 1158; made corrections and changes as noted in CCR 3333
Aug-2014 A UFGS 35 01 70.13 Wire Rope for Gate Operating Devices C 1 Made minor editorial corrections
Aug-2014 A UFGS 35 31 19 Stone, Channel, Shoreline/Coastal Protection for Structures C 1 Deleted the mention of Section 00 41 00 BID SCHEDULES, from subpart 1.4.1.1, and 1.4.2, this section was deleted from the UFGS Database
Aug-2014 S UFGS 42 22 13.00 40 Centrifugal Process Chillers and Coolers R Tri Annual Database Maintenance (TADM) completed
Aug-2014 S UFGS 42 22 16.00 40 Reciprocating Process Chillers and Coolers R Tri Annual Database Maintenance (TADM) completed
Aug-2014 S UFGS 42 23 13.00 40 Process Condensers R Tri Annual Database Maintenance (TADM) completed
Aug-2014 S UFGS 43 41 16.16 40 Vertical Atmospheric Tanks and Vessels R Tri Annual Database Maintenance (TADM) completed
Aug-2014 A UFGS 46 53 62 Continuous Loop Reactor (CLR) Wastewater Treatment System C 1 Added paint requirements as noted in CCR 2518
Aug-2014 A UFGS 46 61 00 Filtration Equipment C 1 Added paint requirements as noted in CCR 2519
Aug-2014 A UFGS 46 73 00.35 Sludge-Digester Gas, Heating, and Mixing System C 1 Deleted publication as noted in CCR 776
Aug-2014 A UFGS 46 76 23.16 Recessed Chamber Filter Presses C 1 Added paint requirements as noted in CCR 2520