Below is a listing of the Revisions and Changes made to UFGS Sections for each release. You can narrow the list by selecting a UFGS Release date from the drop-down and clicking 'Apply'.
| KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA [ARCHIVED] | 
|---|---|---|---|---|---|
| ACTION | N New | R Revision | C Change | D Deletion | 
| Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision | 
|---|---|---|---|---|---|---|
| May-2011 | S | UFGS 05 72 00 Decorative Metal Specialties | May-2011 | R | CCR 496: Minor revisions | |
| May-2011 | N | UFGS 06 10 00 Rough Carpentry | May-2011 | R | Reference updates: modified subparts 2.5.10.2 and 3.5; Removed subparts 2.6.5 and 2.6.9 | |
| May-2011 | N | UFGS 07 19 00 Water Repellents | May-2011 | R | Reference update: modified subpart 2.3.1 through 2.3.4 | |
| May-2011 | N | UFGS 07 21 13 Board and Block Insulation | May-2011 | R | Reference update: modified subpart 2.1.2 | |
| May-2011 | N | UFGS 07 21 16 Mineral Fiber Blanket Insulation | May-2011 | R | Reference update: modified subpart 2.1 | |
| May-2011 | N | UFGS 07 21 23 Loose Fill Thermal Insulation | May-2011 | R | Reference update: modified subpart 2.1 | |
| May-2011 | N | UFGS 07 22 00 Roof and Deck Insulation | May-2011 | R | Reference updates: Modified General Note, subparts 1.2 (note) and 2.1.1 | |
| May-2011 | N | UFGS 07 24 00 Exterior Insulation and Finish Systems | May-2011 | R | Reference update: modified subpart 1.4 | |
| May-2011 | N | UFGS 07 31 13 Asphalt Shingles | May-2011 | R | Reference update: modified subpart 2.1.1 | |
| May-2011 | N | UFGS 07 41 13 Metal Roof Panels | May-2011 | R | Reference update: modified General Note and subparts 1.2.1 and 2.2 | |
| May-2011 | N | UFGS 07 42 13 Metal Wall Panels | May-2011 | R | Reference update: modified subparts 2.2.3.6 and 2.5.4.2 | |
| May-2011 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | May-2011 | R | Reference update: modified subparts 1.3.1 and 2.1.5 | |
| May-2011 | N | UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing | May-2011 | R | Reference update: modified tables in subparts 2.2.3 and 2.2.4 | |
| May-2011 | N | UFGS 07 61 14.00 20 Steel Standing Seam Roofing | May-2011 | R | Reference updates: modified notes in subparts 1.3.2.1, 1.3.2.2, 1.3.2.3, 1.6.6; Modified subparts 1.6.6 and 2.3 | |
| May-2011 | N | UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing | May-2011 | R | Reference updates: modified subparts 1.3.2.1 (notes) and 2.5.3 | |
| May-2011 | N | UFGS 08 14 00 Wood Doors | May-2011 | R | Reference updates: modified subparts 1.5 (note) and 2.3.6.1 | |
| May-2011 | N | UFGS 08 34 63 Detention Hollow Metal Frames, Doors, and Door Frames | May-2011 | R | Reference update: modified subpart 2.1.2 | |
| May-2011 | N | UFGS 08 44 00 Curtain Wall and Glazed Assemblies | May-2011 | R | Reference update: modified note in subpart 1.8 | |
| May-2011 | N | UFGS 08 51 13 Aluminum Windows | May-2011 | R | Major revision; Modified General Note, subparts 1.3, 1.11, 2.1 and 2.2; Removed 1.9.1 | |
| May-2011 | N | UFGS 08 88 53 Detention and Security Glazing | May-2011 | R | Reference update: modified note in subpart 1.5 | |
| May-2011 | N | UFGS 08 91 00 Metal [Wall] [and] [Door] Louvers | May-2011 | R | Reference update: modified subpart 2.1.5 | |
| May-2011 | N | UFGS 09 26 00 Veneer Plaster | May-2011 | R | Reference update: modified subpart 2.1.3 and 2.1.4 | |
| May-2011 | N | UFGS 09 29 00 Gypsum Board | May-2011 | R | Reference update: modified subparts 2.1.3 (note), 2.1.6, 2.1.8, 3.2.9 (note) | |
| May-2011 | N | UFGS 09 90 00 Paints and Coatings | May-2011 | R | Modified subparts 3.2 and 3.5.3 | |
| May-2011 | N | UFGS 09 96 59 High-Build Glaze Coatings | May-2011 | R | Modified subparts 2.1.3 and 2.3.1 | |
| May-2011 | N | UFGS 09 97 13.16 Interior Coating of Welded Steel Water Tanks | May-2011 | R | Reference update: modified General Note | |
| May-2011 | N | UFGS 09 97 13.25 Maintenance, Repair, and Coating of Tall Antenna Towers | May-2011 | R | Reference update: modified note in subpart 3.1.4 | |
| May-2011 | N | UFGS 09 97 23.13 Interior Lining For Concrete Storage Tanks (For Petroleum Fuels) | May-2011 | R | Reference update: modified notes in subparts 2.1, 2.3, 2.4, 2.4.2-4, 3.4 | |
| May-2011 | A | UFGS 10 22 26.33 Folding Panel Partitions | Aug-2010 | D | Superseded without revision by UFGS 10 22 39 Folding Panel Partitions to comply with MasterFormat 2010. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| May-2011 | A | UFGS 10 22 26.43 Sliding Partitions | Aug-2010 | D | Superseded without revision by UFGS 10 22 43 Sliding Partitions to comply with MasterFormat 2010. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| May-2011 | A | UFGS 10 22 39 Folding Panel Partitions | May-2011 | N | Renumbered/Superseding UFGS 10 22 26.33 without revision to comply with MF 2010 | |
| May-2011 | A | UFGS 10 22 43 Sliding Partitions | May-2011 | N | Renumbered/Superseding UFGS 10 22 26.43 without revision to comply with MF 2010 | |
| May-2011 | N | UFGS 10 51 13 Lockers | May-2011 | R | Reference update: modified subpart 2.2.1 | |
| May-2011 | N | UFGS 11 53 00 Laboratory Equipment and Fumehoods | May-2011 | R | Reference update: modified subpart 2.1.2 | |
| May-2011 | N | UFGS 11 70 00 General Requirements for Medical and Dental Equipment | May-2011 | R | Reference update: modified subpart 1.4 | |
| May-2011 | N | UFGS 13 34 19 Metal Building Systems | May-2011 | R | Reference update: modified subparts 2.4.5 and 3.1.3 | |
| May-2011 | N | UFGS 21 12 00 Standpipe Systems | May-2011 | R | Reference update: modified subpart 1.6.1 | |
| May-2011 | N | UFGS 21 22 00.00 20 Halon 1301 Fire Extinguishing | May-2011 | R | Reference update: modified notes in subpart 1.3 and 1.4 | |
| May-2011 | N | UFGS 22 15 19.19 20 Nonlubricated Rotary Screw Air Compressors (100 HP and Larger) | May-2011 | R | Reference update: modified note in subpart 2.2 | |
| May-2011 | A | UFGS 23 09 23 LonWorks Direct Digital Control for HVAC and Other Building Control Systems | May-2011 | R | Allow ductile iron bodies in paragraph BUTTERFLY VALVES  | 
              |
| May-2011 | S | UFGS 26 05 70.00 40 High-Voltage Overcurrent Protective Devices | May-2011 | R | CCR 403: Minor revisions | |
| May-2011 | F | UFGS 26 05 71.00 40 Low-Voltage Overcurrent Protective Devices | May-2011 | R | CCR 404: Minor revisions | |
| May-2011 | N | UFGS 26 35 43 400-Hertz (HZ) Solid State Frequency Converter | May-2011 | R | Reference update: modified note in subpart 1.4.2 | |
| May-2011 | S | UFGS 26 55 53 Security Lighting | May-2011 | R | CCR 428: Minor revisions | |
| May-2011 | S | UFGS 26 60 13.00 40 Low-Voltage Motors | May-2011 | R | CCR 430: Minor revisions | |
| May-2011 | A | UFGS 27 51 23.10 Intercommunication System | May-2011 | N | Renumbered/Superseding UFGS 33 82 01 without revision to comply with MF 2010 | |
| May-2011 | N | UFGS 32 01 17.62 Paving Fabric Interlayer | May-2011 | R | Reference update: modified note in subpart 3.1.1.2 | |
| May-2011 | A | UFGS 33 52 43 Aviation Fuel Distribution (Non-Hydrant) | May-2011 | N | New section superseding UFGS 33 52 13 Exterior Fuel Distribution and UFGS 33 52 43.00 20 Aviation Fuel Distribution and Dispensing | |
| May-2011 | N | UFGS 33 56 13.14 Fiberglass-Plastic Lining for Steel Tank Bottoms (for Petroleum) | May-2011 | R | Reference update: modified note in subpart 2.1.2.1 | |
| May-2011 | A | UFGS 33 82 01 Intercommunication System | Aug-2009 | D | Superseded without revision by UFGS 27 51 23.10 Intercommunication System to comply with MasterFormat 2010. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| May-2011 | N | UFGS 35 59 13.16 Extruded and Molded Marine Fenders | May-2011 | R | Reference update: modified note in subpart 1.6 | |
| May-2011 | S | UFGS 42 22 00.00 40 Process Chillers and Coolers | May-2011 | R | CCR 129; CCR 130: Minor revisions | |
| May-2011 | S | UFGS 42 22 16.00 40 Reciprocating Process Chillers and Coolers | May-2011 | R | CCR 132: Minor revisions | |
| May-2011 | S | UFGS 48 14 13.00 20 Solar Liquid Flat Plate and Evacuated Tube Collectors | May-2011 | R | Reference update: modified notes in subparts 1.4.1 and 1.5 | |
| Feb-2011 | N | UFGS 00 01 15 List of Drawings | Feb-2011 | R | Deleted references to diskettes | |
| Feb-2011 | N | UFGS 01 20 00.00 20 Price and Payment Procedures | Feb-2011 | R | Major revision | |
| Feb-2011 | S | UFGS 01 33 00 Submittal Procedures | Feb-2011 | R | Revised subpart 1.9.4; added subpart 1.9.4.1, 1.9.4.2; minor revisions throughout; tailoring tags were corrected; CCR #82 / CCR #340 - comments were incorporated  | 
              |
| Feb-2011 | S | UFGS 03 41 33 Precast Structural Pretensioned Concrete | Feb-2011 | R | CCR # 489 - comments were incorporated | |
| Feb-2011 | A | UFGS 04 20 00 Unit Masonry | Feb-2011 | R | Add Single-Wythe Masonry Wall Water Penetration Test (CCR 299) | |
| Feb-2011 | S | UFGS 05 52 00 Metal Railings | Feb-2011 | R | Revised General Note, added subpart 1.2, 2.2, 3.1; submittal article compliance; deleted subpart 2.1.2; other minor revisions throughout. | |
| Feb-2011 | S | UFGS 06 71 33 Fiberglass Reinforced Plastic (FRP) Ladders | Feb-2011 | R | CCR # 498 - comments were incorporated; minor revision in subpart 2.4 | |
| Feb-2011 | A | UFGS 07 81 00 Spray-Applied Fireproofing | Feb-2011 | R | CCR 447: Added Spray-Applied Intumescent Epoxy Coating System. Added tailoring for the new system.  | 
              |
| Feb-2011 | A | UFGS 08 13 73 Sliding Metal Doors | Feb-2011 | R | Incorporated recommended technology provided under CCR 437 | |
| Feb-2011 | S | UFGS 08 41 13 Aluminum-Framed Entrances and Storefronts | Feb-2011 | R | Minor revisions in subpart 1.3.1.4, 1.8 | |
| Feb-2011 | N | UFGS 08 53 00 Plastic Windows | Feb-2011 | R | Subpart 2.1 removed Navy tailoring; subpart 2.3 removed notes; para 2.3.3-2.3.7 removed measurements; other minor revisions throughout | |
| Feb-2011 | N | UFGS 08 81 00 Glazing | Feb-2011 | R | Subpart 2.2 modified; minor revisions throughout | |
| Feb-2011 | S | UFGS 12 48 13.13 Entrance Floor Mats | Feb-2011 | R | CCR #531 - comments were incorporated | |
| Feb-2011 | N | UFGS 13 17 43 Hydrotherapy Equipment | Feb-2011 | N | Superseding UFGS 44 44 46 Hydrotherapy Equipment without revision to comply with MF 2010 | |
| Feb-2011 | A | UFGS 22 00 70 Plumbing for Healthcare Facilities | Feb-2011 | R | Minor clarifications throughout | |
| Feb-2011 | S | UFGS 22 07 19 Plumbing Piping Insulation | May-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 22 07 19.00 40 with no title change Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 22 07 19.00 40 Plumbing Piping Insulation | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 22 07 19 with no title change | |
| Feb-2011 | A | UFGS 22 13 23 Sewage Bar Screen and Mechanical Shredder | Apr-2006 | D | Superseded by UFGS  46 20 20 Sewage Bar Screen and Mechanical Shredder without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | A | UFGS 22 13 29 Sanitary Sewerage Pumps | Feb-2011 | N | Superseding UFGS 44 46 00 Pumps; Sewage and Sludge without revision to comply with MF 2010 | |
| Feb-2011 | S | UFGS 22 14 29 Sump Pumps | Aug-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 22 14 29.00 40 with same title and CCR #544 comments incorporated Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 22 14 29.00 Sump Pumps | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 22 14 29 with no title change; CCR #544 comments have been incorporated | |
| Feb-2011 | S | UFGS 22 15 09 General Service Compressed-Air Systems Cleaning Procedures | Aug-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 22 15 09.00 40 with same title and CCR #545 comments incorporated Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 22 15 09.00 40 General Service Compressed-Air Systems Cleaning Procedures | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 22 15 09 with no title change; CCR #545 comments have been incorporated | |
| Feb-2011 | S | UFGS 22 15 13.16 40 High-Pressure Compressed-Air Piping and Valves, Stainless | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 22 15 13.16 with no title change | |
| Feb-2011 | S | UFGS 22 15 13.16 High-Pressure Compressed-Air Piping, Piping Components, and Valves, Stainless | Feb-2009 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 22 15 13.16 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 22 15 14 General Service Compressed-Air Systems, Low Pressure | Aug-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 22 15 14.00 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 22 15 14.00 40 General Service Compressed-Air Systems, Low Pressure | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 22 15 14 with no title change | |
| Feb-2011 | S | UFGS 22 66 53 Laboratory Chemical-Waste and Vent Piping | Aug-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 22 66 53.00 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 22 66 53.00 40 Laboratory Chemical-Waste and Vent Piping | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 22 66 53 with no title change | |
| Feb-2011 | S | UFGS 23 05 48 Vibration and Seismic Controls for HVAC Piping and Equipment | Nov-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 23 05 48.00 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 23 05 48.00 40 Vibration and Seismic Controls for HVAC Piping and Equipment | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 23 05 48 with no title change | |
| Feb-2011 | S | UFGS 23 09 13.34 40 Control Valves, Self-Contained | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 23 09 13.34 with no title change | |
| Feb-2011 | S | UFGS 23 09 13.34 Control Valves, Self-Contained | Nov-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 23 09 13.34 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 23 22 13.35 40 Steam Traps | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 23 22 13.35 with no title change | |
| Feb-2011 | S | UFGS 23 22 13.35 Steam Traps | May-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 23 22 13.35 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 23 22 23 Steam Condensate Pumps | Aug-2008 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 23 22 23.00 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 23 22 23.00 40 Steam Condensate Pumps | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 23 22 23 with no title change | |
| Feb-2011 | S | UFGS 23 22 25 Steam Valves | Nov-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 23 22 25.00 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 23 22 25.00 40 Steam Valves | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 23 22 25 with no title change | |
| Feb-2011 | S | UFGS 23 31 13 Metal Ducts | Feb-2009 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 23 31 13.00 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 23 31 13.00 40 Metal Ducts | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 23 31 13 with no title change | |
| Feb-2011 | S | UFGS 23 34 23 HVAC Power Ventilators | Feb-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 23 34 23.00 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 23 34 23.00 40 HVAC Power Ventilators | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 23 34 23 with no title change | |
| Feb-2011 | S | UFGS 23 36 00 Air Terminal Units | Nov-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 23 36 00.00 40 with same title and CCR #574 comments incorporated Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  | 
              |
| Feb-2011 | S | UFGS 23 36 00.00 40 Air Terminal Units | Feb-2011 | N | Renumbered to NASA fifth level; Superseding UFGS 23 36 00 with no title change; CCR #574 comments have been incorporated | |
| Feb-2011 | S | UFGS 23 73 13 Modular Indoor Central-Station Air-Handling Units | Aug-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 23 73 13.00 40 with same title and CCR #604 comments incorporated Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.  |