Export to CSV

Below is a listing of the Revisions and Changes made to UFGS Sections for each release. You can narrow the list by selecting a UFGS Release date from the drop-down and clicking 'Apply'.

KEYPREPARING ACTIVITY (PA)A ArmyN NavyF Air ForceS NASA [ARCHIVED]
ACTIONN NewR RevisionC ChangeD Deletion
Release PA UFGS Section Action Change # Nature of Change or Revision
Aug-2017 A UFGS 32 17 23 Pavement Markings C 3 Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS).
Aug-2017 A UFGS 32 18 16.13 Playground Protective Surfacing R Complete review and update including sustainability updates , formatting to meet UFC 1-300-02, reference updates and general revisions.
Aug-2017 N UFGS 32 92 19 Seeding R Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions.
Aug-2017 N UFGS 32 92 26 Sprigging R Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions.
Aug-2017 N UFGS 32 93 00 Exterior Plants R Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions.
Aug-2017 N UFGS 32 96 00 Transplanting Exterior Plants R Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions.
Aug-2017 N UFGS 33 11 00 Water Utility Distribution Piping C 1 Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide, Open Protocol, Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities.
Aug-2017 A UFGS 33 11 13 Potable Water Supply Wells N Superseding UFGS 33 20 00 Water Wells. Complete review and update including section number and and title changes.
Aug-2017 N UFGS 33 11 23 Natural Gas and Liquid Petroleum Piping C 1 Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide , Open Protocol , Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities.
Aug-2017 A UFGS 33 16 15 Water Storage Steel Tanks C 1 Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS).
Aug-2017 A UFGS 33 20 00 Water Wells D Superseded by UFGS 33 11 13 Potable Water Supply Wells.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 N UFGS 33 24 00.00 20 [Extraction] [Monitoring] Wells D Superseded by new unified section UFGS 33 51 39 Monitoring Wells.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 A UFGS 33 24 13 Groundwater Monitoring Wells D Superseded by new unified section UFGS 33 51 39 Monitoring Wells.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 A UFGS 33 51 15 Natural-Gas / Liquid Petroleum Gas Distribution Pipelines C 1 Updated requirements for natural gas compliance with 49 CFR 192.
Aug-2017 S UFGS 33 51 39 Monitoring Wells N New section through unification of (and Superseding) UFGS 33 24 00 00 20 [Extraction] [Monitoring] Wells and UFGS 33 24 13 Groundwater Monitoring Wells
Aug-2017 N UFGS 33 65 00 Cleaning Petroleum Storage Tanks C 1 Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS).
Aug-2017 A UFGS 40 05 13 Pipelines, Liquid Process Piping C 1 Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS).
Aug-2017 S UFGS 42 22 13.00 40 Centrifugal Process Chillers and Coolers R Tri-Annual Database Maintenance (TADM) completed .
Aug-2017 S UFGS 42 22 16.00 40 Reciprocating Process Chillers and Coolers R Tri-Annual Database Maintenance (TADM) completed .
Aug-2017 S UFGS 42 23 13.00 40 Process Condensers R Tri-Annual Database Maintenance (TADM) completed .
Aug-2017 A UFGS 43 21 13 Pumps: Water, Centrifugal D Superseded by UFGS 23 21 23 Hydronic Pumps.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 A UFGS 43 21 39 Pumps: Water, Vertical Turbine D Superseded by UFGS 23 21 23 Hydronic Pumps.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 A UFGS 43 31 13.14 Downflow Liquid Activated Carbon Adsorption Units C 1 Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS).
Aug-2017 A UFGS 43 32 69 Chemical Feed Systems D Superseded by UFGS 46 30 00 Water and Wastewater Chemical Feed Systems.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 A UFGS 43 32 76 Chlorine-Feeding Machines (Automatic, Semiautomatic and Manual) D Superseded by UFGS 46 31 11 Chlorine Gas Feed Equipment.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 S UFGS 43 41 16.16 40 Vertical Atmospheric Tanks and Vessels R Tri-Annual Database Maintenance (TADM) completed .
Aug-2017 A UFGS 46 30 00 Water and Wastewater Chemical Feed Systems N Superseding UFGS 43 32 69 Chemical Feed Systems; Complete review and update including section number and and title changes.
Aug-2017 A UFGS 46 31 11 Chlorine Gas Feed Equipment N Superseding UFGS 43 32 76 Chlorine-Feeding Machines (Automatic, Semiautomatic and Manual); Complete review and update including section number and and title changes.
May-2017 N UFGS 01 31 23.13 20 Electronic Construction and Facility Support Contract Management System (eCMS) N New Section
May-2017 A UFGS 01 78 24.00 10 Facility Data Requirements R Total review and update. Section title changed from Operations and Maintenance Facility Data Requirements
May-2017 N UFGS 02 82 16.00 20 Engineering Control of Asbestos Containing Materials C 1 In response to CCR 5044, updated language in paragraph 3.1.3.2 for the Asbestos Warning Label per OSHA 1926.1101(k)(8)(iii).
May-2017 N UFGS 05 50 13 Miscellaneous Metal Fabrications R Addressed the following CCRs: 1669-Include welded headed shear studs; 3556-Access Doors and panels relocated to new UFGS 08 31 00 ACCESS DOORS AND PANELS; Added different types of downspout terminations
May-2017 S UFGS 05 51 00 Metal Stairs C 1 Incorporated CCR 5531, revised paragraphs 2.4.1, and 2.4.2
May-2017 N UFGS 07 11 13 Bituminous Dampproofing C 1 In response to CCR 1816, updated para 1.3-Delivery and Storage
May-2017 N UFGS 07 27 19.01 Self-Adhering Air Barriers N New specifications for vapor permeable and vapor retarding self-adhering air barrier systems as part of building enclosure system. Use this section in conjunction with Section 07 27 10.00 10, BUILDING AIR BARRIER SYSTEM and Section 07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS.
May-2017 N UFGS 07 27 26 Fluid-Applied Membrane Barriers N New specifications for vapor permeable and vapor retarding fluid applied air barrier systems as part of the building enclosure system. Use this section in conjunction with Section 07 27 10.00 10, BUILDING AIR BARRIER SYSTEM and Section 07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS.
May-2017 N UFGS 07 27 36 Spray Foam Air Barriers N New specifications for open and closed cell spray polyurethane foam (SPF) air barrier systems as part of the building enclosure system. Use this section in conjunction with Section 07 27 10.00 10, BUILDING AIR BARRIER SYSTEM and Section 07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS.
May-2017 N UFGS 07 60 00 Flashing and Sheet Metal R Addressed CCR 3360 which establishes Energy Star requirements.
May-2017 N UFGS 08 11 16 Aluminum Doors and Frames R Addressed the following CCRs: 1822-Air Infiltration requirements; 2330-Water penetration and insulation requirements; 2393-Requirements for ATFP and windborne debris regions; and 2392-Update requirements for thermal performance
May-2017 N UFGS 08 31 00 Access Doors and Panels N New Section
May-2017 N UFGS 08 34 16 Corrosion Control Hangar Doors R Complete revision as part of the normal refresh cycle and to coordinate with concurrent revisions to UFC 4-211-01 which is becoming a Tri-Service document.
May-2017 N UFGS 08 34 16.10 Horizontal Rolling Steel Doors R Complete revision as part of the normal refresh cycle and to coordinate with concurrent revisions to UFC 4-211-01 which is becoming a Tri-Service document.
May-2017 A UFGS 10 14 53 Traffic Signage C 1 In response to CCR 4523, updated references and incorporated minor changes.
May-2017 S UFGS 22 14 29.00 Sump Pumps R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 23 73 13.00 40 Modular Indoor Central-Station Air-Handling Units R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 23 73 13.00 40 Modular Indoor Central-Station Air-Handling Units R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 23 74 33.00 40 Small HVAC Units, Cooling-Only, Recirculating, Split and Unitary for Window and Floor Mounting R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 23 82 19.00 40 Fan Coil Units R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 23 82 19.00 40 Fan Coil Units R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 23 82 23.00 40 Unit Ventilators R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 23 82 23.00 40 Unit Ventilators R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 23 82 43.00 40 Electric Duct Heaters R Tri-Annual Database Maintenance (TADM) completed
May-2017 N UFGS 23 82 46.00 40 Electric Unit Heaters R Tri-Annual Database Maintenance (TADM) completed
May-2017 N UFGS 25 50 00.00 20 Cybersecurity of Facility-Related Control Systems C 1 Clarified contractor requirements throughout. Revised the subparagraphs of 1.2.4 to remove requirements to be performed by the Government and to clarify the Contractor's requirements. CCR 5584: Revised 1.2 and 3.1 to read QUALITY CONTROL and FIELD QUALITY CONTROL, respectively. CCR 5629: Clarified 1.2.1 and 1.2.2 to provide submittal via Registered Mail.
May-2017 N UFGS 26 12 19 Pad-Mounted, Liquid-Filled, Medium Voltage Transformers R Revision included updating the minimum efficiency to meet 10 CFR 431, Subpart K, and meeting additional changes in transformer technology.
May-2017 N UFGS 26 12 21 Single-Phase Pad-Mounted Transformers R Revision included updating the minimum efficiency to meet 10 CFR 431, Subpart K, and meeting additional changes in transformer technology.
May-2017 S UFGS 26 28 21.00 40 Automatic Transfer Switches R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 27 05 28.36 40 Cable Trays for Communications Systems R Tri-Annual Database Maintenance (TADM) completed
May-2017 N UFGS 31 31 16.19 Termite Control Barriers C 1 Changes made to include a note for Air Force to use Chemical Termite Control and deleting reference to ASTM C289 in response to CCR 4978.
May-2017 A UFGS 32 01 13 Bituminous Seal and Fog Coats D Superseded by UFGS 32 12 36.13 Asphaltic Seal and Fog Coats.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2017 A UFGS 32 01 17.16 Sealing of Cracks in Bituminous Pavements D Superseded by UFGS 32 01 17.61 Sealing Cracks in Asphalt Paving.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2017 A UFGS 32 01 17.61 Sealing Cracks in Asphalt Paving N Superseding UFGS 32 01 17.16 Sealing of Cracks in Bituminous Pavements; Total review and update.
May-2017 A UFGS 32 01 18.71 Grooving of Airfield Paving N Superseding UFGS 32 01 26.71 Grooving for Airfield Pavements; Total review and update.
May-2017 A UFGS 32 01 26.71 Grooving for Airfield Pavements D Superseded by UFGS 32 01 18.71 Grooving of Airfield Paving.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2017 A UFGS 32 01 29.61 Partial Depth Patching of Rigid Paving R Total review and update.
May-2017 A UFGS 32 01 29.62 Concrete Pavement Raising C 1 In response to CCR 2107, changed section title for compliance to the MasterFormat 2011 update.
May-2017 N UFGS 32 10 00 [Pervious] Bituminous Concrete Pavement D Pervious Bituminous Concrete Pavement lacks an acceptable industry standard and the majority of Installations do not have acceptable maintenance practices in place to perform required maintenance.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2017 A UFGS 32 12 10 Bituminous Tack and Prime Coats D Superseded by UFGS 32 12 13 with same title.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2017 A UFGS 32 12 13 Bituminous Tack[ and][ Prime] Coats N Superseding UFGS 32 12 10; Total review and update with no title change.
May-2017 A UFGS 32 12 36.13 Bituminous Fog Seal N Superseding UFGS 32 01 13 Bituminous Seal and Fog Coats; Total review and update.
May-2017 A UFGS 32 15 00 Aggregate Surfacing R Total review and update; Section title changed from Aggregate Surface Course.
May-2017 A UFGS 32 17 23 Pavement Markings C 2 In response to CCR 5549, removed "Gradation A" from Type III beads.
May-2017 S UFGS 32 31 13 Chain Link Fences and Gates C 1 Incorporated CCR 4487, revised paragraphs 2.2.15, and 2.2.17
May-2017 N UFGS 32 84 24 Irrigation Sprinkler Systems C 1 Changes made to address CCRs 5293, 5294, 5305, 5306, and 5307
May-2017 A UFGS 33 40 00 Stormwater Utilities C 5 Added requirements for field quality control.
May-2017 S UFGS 33 77 36.00 40 Medium-Voltage Utility Fuses R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 33 77 36.00 40 Medium-Voltage Utility Fuses R Tri-Annual Database Maintenance (TADM) completed
May-2017 A UFGS 34 71 13.16 Vehicle Crash Barriers C 1 In response to CCR 4568, updated references and incorporated minor changes.
May-2017 S UFGS 40 18 00.00 40 Vacuum Systems Process Piping R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 40 18 00.00 40 Vacuum Systems Process Piping R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 42 22 00.00 40 Process Chillers and Coolers R Tri-Annual Database Maintenance (TADM) completed
May-2017 S UFGS 42 22 00.00 40 Process Chillers and Coolers R Tri-Annual Database Maintenance (TADM) completed
May-2017 F UFGS 48 14 00 Solar Photovoltaic Systems N New Section.
May-2017 N UFGS 48 15 00 Wind Generator System N New Section.
May-2017 A UFGS 48 16 00 Landfill Gas Systems N New Section.
Feb-2017 N UFGS 01 33 29 Sustainability Requirements and Reporting R Required revisions in order to align with numerous changes in Federal requirements and DOD policy.
Feb-2017 N UFGS 01 35 26 Governmental Safety Requirements C 4 Added crane requirements for Critical Lift Plan, Barge Mounted, and Base Mounted Drum Hoists from NAVFAC P-307 that were not in EM 385-1-1. For Navy, added requirement of accident investigation reporting within 5 days of mishaps and 10 days of accidents.
Feb-2017 S UFGS 01 75 00.00 40 Starting and Adjusting D This Section has been retired / Action Item from the Fall 2016 Specification DWG Meeting.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2017 A UFGS 01 91 00.15 Building Commissioning C 1 In response to CCR 5173, added two "S" submittals in SD-11.
Feb-2017 A UFGS 02 53 13 Remediation of Contaminated Soils and Sludges by Incineration D UFGS archived. Outdated specification and no longer use incineration for contaminated soils.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2017 N UFGS 02 83 13.00 20 Lead in Construction C 1 CCR 5279: updated paragraph 1.5.2.2 Lead Compliance Plan.
Feb-2017 S UFGS 05 51 00 Metal Stairs R Tri-Annual Database Maintenance (TADM) completed
Feb-2017 S UFGS 05 51 00 Metal Stairs R Tri-Annual Database Maintenance - Subpart 1.2 Submittal Article Compliance
Feb-2017 N UFGS 07 22 00 Roof and Deck Insulation C 1 CCR 5475: Changed terminology within this section from “Protection Board” to “Cover Board”.
Feb-2017 S UFGS 23 09 13.34 40 Control Valves, Self-Contained R Tri-Annual Database Maintenance (TADM) completed
Feb-2017 N UFGS 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC C 1 BACnet Operator Workstation (B-OWS) updated to BACnet Advanced Operator Workstation (B-AWS) in 2.1.6.2-[BACnet Operator Workstation][and][Notebook Computer] DDC Software.
Feb-2017 S UFGS 23 22 13.35 40 Steam Traps R Tri-Annual Database Maintenance (TADM) completed
Feb-2017 S UFGS 23 34 23.00 40 HVAC Power Ventilators R Tri-Annual Database Maintenance (TADM) completed
Feb-2017 S UFGS 23 34 23.00 40 HVAC Power Ventilators R Tri-Annual Database Maintenance (TADM) completed
Feb-2017 N UFGS 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems C 4 Updated Technical Note in 2.2.2-Fittings and End Connections (Joints)