Export to CSV

Below is a listing of the Revisions and Changes made to UFGS Sections for each release. You can narrow the list by selecting a UFGS Release date from the drop-down and clicking 'Apply'.

KEYPREPARING ACTIVITY (PA)A ArmyN NavyF Air ForceS NASA [ARCHIVED]
ACTIONN NewR RevisionC ChangeD Deletion
Release PA UFGS Section Action Change # Nature of Change or Revision
Feb-2019 N UFGS 03 31 30 Marine Concrete N New marine concrete section developed for projects not requiring concrete service life modeling.
Feb-2019 A UFGS 03 35 00.00 10 Concrete Finishing D This UFGS is no longer required and is superseded by UFGS 03 30 00 CAST-IN-PLACE CONCRETE.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2019 A UFGS 03 39 00.00 10 Concrete Curing D This UFGS is no longer required and is superseded by UFGS 03 30 00 CAST-IN-PLACE CONCRETE.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2019 A UFGS 08 39 53 Blast Resistant Doors (Earth Covered Magazines) R Complete review and update including section title change from BLAST RESISTANT DOORS (OVAL ARCH MAGAZINES) to BLAST RESISTANT DOORS (EARTH COVERED MAGAZINES). PA changed from NAVFAC to ARMY.
Feb-2019 N UFGS 12 35 30.23 20 Bathroom Casework R Non-technical revision; Formerly titled UFGS 12 36 00.00 20 MANUFACTURED VANITIES; In response to CCR# 7057, section number and title have been revised (with no section date change) to conform with CSI MasterFormat.
Feb-2019 N UFGS 12 36 00.00 20 Manufactured Vanities D To conform with CSI MasterFormat, Section 12 36 00.00 20 MANUFACTURED VANITIES has been renumbered and renamed as Section 12 35 30.23 20 BATHROOM CASEWORK with no date change.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2019 A UFGS 21 13 25 High-Expansion Foam System, Fire Protection N New UFGS.
Feb-2019 A UFGS 23 09 00 Instrumentation and Control for HVAC R Complete review and update.
Feb-2019 A UFGS 23 09 00 Instrumentation and Control for HVAC R Complete review and update.
Feb-2019 A UFGS 23 09 23.01 Lonworks Direct Digital Control for HVAC and Other Building Control Systems R Complete review and update.
Feb-2019 A UFGS 23 09 23.01 Lonworks Direct Digital Control for HVAC and Other Building Control Systems R Complete review and update.
Feb-2019 A UFGS 23 09 23.02 BACnet Direct Digital Control for HVAC and Other Building Control Systems R Complete review and update.
Feb-2019 A UFGS 23 09 23.02 BACnet Direct Digital Control for HVAC and Other Building Control Systems R Complete review and update.
Feb-2019 A UFGS 25 10 10 Utility Monitoring and Control System (UMCS) Front End and Integration R Complete review and update.
Feb-2019 A UFGS 26 54 21.00 10 Helipad Lighting and Visual Navigation Aids D Superseded by UFGS 26 56 20 AIRFIELD AND HELIPORT LIGHTING AND VISUAL NAVIGATION AIDS.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2019 A UFGS 26 56 20 Airfield and Heliport Lighting and Visual Navigation Aids N Superseding UFGS 26 54 21.00 10 HELIPAD LIGHTING AND VISUAL NAVIGATION AIDS, UFGS 26 56 20.00 10 AIRFIELD AND HELIPORT LIGHTING AND VISUAL NAVIGATION AIDS, and UFGS 34 43 00.00 20 AIRFIELD LIGHTING. Complete review and update.
Feb-2019 A UFGS 26 56 20.00 10 Airfield and Heliport Lighting and Visual Navigation Aids D Superseded by UFGS 26 56 20 AIRFIELD AND HELIPORT LIGHTING AND VISUAL NAVIGATION AIDS.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2019 A UFGS 32 12 15.16 Stone Matrix Asphalt (SMA) for Airfield Paving N Section number reinstated; Superseding UFGS 32 13 17 STONE MATRIX ASPHALT (SMA) FOR AIRFIELD PAVEMENTS. Complete review and update including section number and title changes.
Feb-2019 A UFGS 32 13 17 Stone Matrix Asphalt (SMA) for Airfield Pavements D Superseded by UFGS 32 12 15.16 STONE MATRIX ASPHALT (SMA) FOR AIRFIELD PAVING.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2019 A UFGS 33 40 00 Stormwater Utilities C 6 Moved the LID Verification Report to SD-11 Closeout Submittals in response to CCR 6353.
Feb-2019 N UFGS 34 43 00.00 20 Airfield Lighting D Superseded by Army Section 26 56 20 AIRFIELD AND HELIPORT LIGHTING AND VISUAL NAVIGATION AIDS.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2019 A UFGS 35 05 40.17 Self-Lubricated Materials, Fabrication, Handling, and Assembly C 2 Updated Hydroelectric Design Center (HDC) phone number and ER reference in response to CCR 7048.
Nov-2018 N UFGS 00 73 03 Supplementary Conditions for Azores Projects D Section is outdated and not used.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 01 14 00 Work Restrictions C 6 Changed tailoring tags from NAVFAC PAC to NAVFAC HI based on CCRs, removed outdated information for Naval Shipyard Pearl Harbor, HI, and added personnel security requirements for use in secure or controlled areas.
Nov-2018 N UFGS 01 32 17.00 20 Cost-Loaded Network Analysis Schedules (NAS) C 1 Corrected notes and paragraphs, for DB and DBB, on Baseline NAS submittals and requirements.
Nov-2018 S UFGS 01 33 00 Submittal Procedures C 1 Submittal Note updated and tailoring changes.
Nov-2018 A UFGS 01 78 00 Closeout Submittals C 4 Deleted reference to NFAS Clause. Added Sustainable Materials certification reporting requirements.
Nov-2018 A UFGS 02 42 91 Removal and Salvage of Historic Construction Materials R Periodic update. Complete review and update.
Nov-2018 A UFGS 02 81 00 Transportation and Disposal of Hazardous Materials R Periodic update. Complete review and update.
Nov-2018 N UFGS 02 82 00 Asbestos Remediation N Update to industry standards and unifying into one Tri-Service UFGS.  Superseding UFGS 02 82 13.00 10 (Army) Asbestos Abatement and UFGS 02 82 16.00 20 (Navy) Engineering Control of Asbestos Containing Materials.
Nov-2018 A UFGS 02 82 13.00 10 Asbestos Abatement D Superseded by new UFGS 02 82 00 ASBESTOS REMEDIATION.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 02 82 16.00 20 Engineering Control of Asbestos Containing Materials D Superseded by UFGS 02 82 00 ASBESTOS REMEDIATION.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 02 82 33.13 20 Removal/Control and Disposal of Paint with Lead D Superseded by UFGS 02 83 00 LEAD REMEDIATION.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 02 83 00 Lead Remediation N Update to industry standards and unifying into one Tri-Service UFGS. Superseding UFGS 02 82 33.13 20 Removal/Control and Disposal of Paint with Lead (Navy), UFGS 02 83 13.00 20 Lead in Construction (Navy), and UFGS 02 83 19.13 10 Lead-Based Paint Abatement (Army).
Nov-2018 N UFGS 02 83 13.00 20 Lead in Construction D Superseded by UFGS 02 83 00 LEAD REMEDIATION.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 A UFGS 02 83 19.13 10 Lead-Based Paint Abatement D Superseded by new UFGS 02 83 00 LEAD REMEDIATION.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 02 85 00 Mold Remediation N Update to industry standards and unifying into one Tri-Service UFGS.  Superseding UFGS 02 85 00.00 20 Mold Remediation.
Nov-2018 N UFGS 02 85 00.00 20 Mold Remediation D Superseded by UFGS 02 85 00 MOLD REMEDIATION.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 03 30 00 Cast-In-Place Concrete C 4 Added note to use UFGS 03 31 29 or UFGS 03 31 30 in ESC C4 and C5 locations or where deicing salts.
Nov-2018 N UFGS 03 31 29 Marine Concrete with Service Life Modeling C 2 Added notes to direct use of this section and Type II and V Portland cement in ESC C4 and C5 locations and where deicing salts used on structure, note for coral aggregates, and note for water reducing.
Nov-2018 S UFGS 03 41 33 Precast Structural Pretensioned Concrete C 1 Added requirement and note to use galvanized tendons in ESC C4 and C5 locations, and concrete cover requirements for tendon anchorages for post tensioning.
Nov-2018 A UFGS 04 20 00 Unit Masonry C 1 Added Single-Wythe Exterior Wall CMU Flashing System, requirements for tooled joints, and note for load-bearing unit types.
Nov-2018 N UFGS 05 12 00 Structural Steel C 1 Added note for shop primer requirements in exterior locations or areas open to the exterior.
Nov-2018 N UFGS 06 10 00 Rough Carpentry C 2 Added notes for requirement of preservative treatment and hot-dip galvanized rough hardware in ESC C3 thru C5 and humid locations, and not to use particle board or OSB in C4 and C5 and humid locations.
Nov-2018 A UFGS 06 17 19 Cross-Laminated Timber C 1 Added recommendation not to use CLT in humid or ESC locations C4 and C5.
Nov-2018 S UFGS 06 18 00 Glued-Laminated Construction C 1 Added Note to not use GLC in ESC C4 and C5 and humid locations.
Nov-2018 N UFGS 06 20 00 Finish Carpentry C 2 Added notes to not use particleboard or hardboard siding in humid or ESC C4 and C5 locations.
Nov-2018 A UFGS 06 41 16.00 10 Plastic-Laminate-Clad Architectural Cabinets C 1 Updated reference in response to CCR 6899.
Nov-2018 N UFGS 07 22 00 Roof and Deck Insulation C 3 Added notes to consider use of polystyrene as a roof insulation in humid or ESC C3-C5 locations and not to use wood fiberboard in humid or ESC C4-C5 locations.
Nov-2018 N UFGS 07 41 13 Metal Roof Panels C 2 Added notes for gauge requirements of Aluminum and Steel Sheet Panels in humid and ESC C3-C5 locations.
Nov-2018 N UFGS 07 51 13 Built-Up Asphalt Roofing C 2 Added notes restricting use of coral gravel in humid and ESC C3-C5 locations and gravel surface cap sheet in humid and ESC C4-C5 locations.
Nov-2018 N UFGS 07 60 00 Flashing and Sheet Metal C 2 Added notes for flashing requirements, lead sheet, thickness of aluminum alloy sheet and plate, and fasteners in humid or ESC C3-C5 locations and nailing in ESC C4-C5 locations.
Nov-2018 N UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing C 2 Added note for use of coated alclad in ESC C3-C5 locations.
Nov-2018 N UFGS 07 92 00 Joint Sealants C 3 Added sealant requirements with ambient temperatures that exceed 43.33 degrees C (110 degrees F).
Nov-2018 N UFGS 08 11 13 Steel Doors and Frames C 3 Added note for door louvers and exterior screens in humid or ESC C3-C5 locations.
Nov-2018 N UFGS 08 11 16 Aluminum Doors and Frames C 2 In paragraph "Finishes," defined corrosive atmospheres in terms of ISO 9223 ESC C3-C5, and humid locations in terms of ASHRAE 90.1.
Nov-2018 N UFGS 08 51 13 Aluminum Windows C 4 Added note for finish requirements in humid and ESC C3-C5 locations.
Nov-2018 N UFGS 08 51 23 Steel Windows C 4 Added note restricting use of steel windows in humid and ESC C3-C5 locations.
Nov-2018 N UFGS 08 52 00 Wood Windows C 4 Added note restricting use of steel windows in humid and ESC C3-C5 locations.
Nov-2018 N UFGS 08 53 00 Plastic Windows C 4 Added note restricting use of plastic windows in humid and ESC C3-C5 locations.
Nov-2018 N UFGS 08 71 00 Door Hardware C 2 Added requirements for hinges, locks and locksets, exit devices, closers, and finishes in humid and ESC C3-C5 locations.
Nov-2018 N UFGS 08 91 00 Metal [Wall] [and] [Door] Louvers C 2 Added note for louver and finish requirements in humid and ESC C3-C5 locations.
Nov-2018 N UFGS 09 22 36 Lath C 2 Added requirements for accessories, hangers, and wires, in high humidity and ESC C3-C5 locations, and straps or rods in locations subject to violent storms.
Nov-2018 N UFGS 09 23 00 Gypsum Plastering C 1 Added mix requirement for acoustical plaster finish coat in high humidity ad ESC C3-C5 locations.
Nov-2018 A UFGS 09 24 23 Cement Stucco C 2 Added requirements for accessories, hangers, and wires, in high humidity and ESC C3-C5 locations, and straps or rods in locations subject to violent storms.
Nov-2018 N UFGS 09 29 00 Gypsum Board C 3 Added requirements to use PVC or plastic trim and accessories in high humidity and ESC C3-C5 locations.
Nov-2018 A UFGS 09 51 00 Acoustical Ceilings C 2 Added requirements for suspension systems materials in high humidity and ESC C3-C5 locations.
Nov-2018 A UFGS 09 64 23 Wood Parquet Flooring C 3 Added note to use termite treated wood in termite prone areas.
Nov-2018 A UFGS 09 64 29 Wood Strip and Plank Flooring C 2 Added note to use termite treated wood flooring in termite prone areas.
Nov-2018 A UFGS 09 66 13 Portland Cement Terrazzo Flooring C 2 Added requirement prohibiting use of coral, dolomite or limestone aggregates in setting bed.
Nov-2018 N UFGS 09 90 00 Paints and Coatings C 4 Added note to use UFGS 03 31 29 or UFGS 03 31 30 in ESC C4 and C5 locations or where deicing salts.
Nov-2018 A UFGS 10 14 00.10 Exterior Signage C 1 Added note for material requirements of exterior sheeting panels, brackets, posts, fasteners, and hardware in ESC C3-C5 locations.
Nov-2018 A UFGS 10 14 00.20 Interior Signage C 2 Added note and material requirements for panels, brackets, fasteners, and hardware for unoccupied spaces and high humidity and ESC C4-C5 locations and for standard room signs in humid and C3-C5 locations.
Nov-2018 A UFGS 10 21 13 Toilet Compartments C 2 Added note and requirement for partitions. Added requirement for panels, brackets, fasteners and hardware in unconditioned spaces and humid and ESC C4-C5 locations.
Nov-2018 A UFGS 12 21 00 Window Blinds C 2 Added requirement for materials in humid and ESC C3-C5 locations.
Nov-2018 S UFGS 12 32 00 Manufactured Wood Casework C 1 Added note for drawer bottoms, plastic laminate covered cabinet doors, and non-ferrous metal fasteners, fittings, and hardware.
Nov-2018 A UFGS 12 35 70 Healthcare Casework C 2 Added note for drawer bottoms, plastic laminate covered cabinet doors, and non-ferrous metal fasteners, fittings, and hardware. Added note prohibiting use of particle board for countertops in high humidity and C3-C5 locations.
Nov-2018 A UFGS 12 50 00.13 10 Furniture and Furniture Installation C 1 Changed title of paragraph 2.3.1 in response to CCR 6726.
Nov-2018 A UFGS 13 49 10 X-Ray Shielding C 1 Updated reference in response to CCRs 6683 and 6685.
Nov-2018 N UFGS 25 50 00.00 20 Cybersecurity of Facility-Related Control Systems D Navy-only Section, including NAVFAC Interim Technical Guidance (ITG 2017-01) – Application of Cybersecurity to Facility-Related Control Systems, is superseded by Tri-Service cybersecurity UFGS Section 25 05 11 Cybersecurity for Facility-Related Control Systems.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 26 32 13.00 20 Single Operation Generator Sets C 1 Deleted now obsolete calculation requirement for Brake Mean Effective Pressure (BMEP).
Nov-2018 A UFGS 31 11 00 Clearing and Grubbing R Complete review and update.
Nov-2018 N UFGS 31 21 13 Radon Mitigation R Periodic update.
Nov-2018 A UFGS 32 01 29.62 Concrete Pavement Raising R Complete review and update including section title change from SLABJACKING RIGID PAVEMENTS to CONCRETE PAVEMENT RAISING.
Nov-2018 A UFGS 32 17 23 Pavement Markings C 5 Updated/replaced references in response to CCR 6522.
Nov-2018 N UFGS 33 01 50.55 Cleaning of Petroleum Storage Tanks R (UFGS-33 01 50.60) Complete review and update including new Section number and title; Superseding UFGS 33 65 00 CLEANING PETROLEUM STORAGE TANKS (Aug-11)
Nov-2018 N UFGS 33 09 52 Fuel Pump Control and Annunciation System (Non-Hydrant) N New section
Nov-2018 N UFGS 33 52 10 Fuel Systems Piping (Service Station) R Complete review and update including Section title change from SERVICE PIPING FUEL SYSTEMS; Preparing Activity changed from Army to Navy
Nov-2018 N UFGS 33 52 23.15 POL Service Piping Welding R Complete review and update including new Section number and title; Superseding UFGS 33 52 90.00 20 WELDING FOR POL SERVICE PIPING (Feb-10)
Nov-2018 N UFGS 33 52 40 Fuel Systems Piping (Non-Hydrant) R Complete review and update including new Section number and title; Superseding UFGS 33 52 43 AVIATION FUEL DISTRIBUTION (NON-HYDRANT) (May-11); Preparing Activity changed from Army to Navy
Nov-2018 A UFGS 33 52 43 Aviation Fuel Distribution (Non-Hydrant) D Superseded by UFGS 33 52 40 FUEL SYSTEMS PIPING (NON-HYDRANT); Preparing Activity changed from Army to Navy.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 33 52 90.00 20 Welding for POL Service Piping D Superseded by UFGS 33 52 23.15 POL SERVICE PIPING WELDING.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 33 56 13.13 Steel Tanks With Fixed Roofs D Superseded by UFGS 33 56 21.17 SINGLE WALL ABOVE GROUND FIXED ROOF STEEL POL STORAGE TANK.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 33 56 13.15 Undertank Interstitial Space D Superseded by UFGS 33 56 21.18 SINGLE WALL POL TANK UNDERTANK INTERSTITIAL SPACE.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 33 56 21.17 Single Wall Aboveground Fixed Roof Steel POL Storage Tank R Complete review and update including new Section number and title; Superseding UFGS 33 56 13.13 STEEL TANKS WITH FIXED ROOFS (Aug-15)
Nov-2018 N UFGS 33 56 21.18 Single Wall POL Tank Undertank Interstitial Space R Complete review and update including new Section number and title; Superseding UFGS 33 56 13.15 UNDERTANK INTERSTITIAL SPACE (Aug-15)
Nov-2018 A UFGS 33 57 00 Bulk Fuel Receiving / Dispensing Equipment D Superseded by UFGS 33 57 55 FUEL SYSTEM COMPONENTS (NON-HYDRANT); Preparing Activity changed from Army to Navy.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 33 57 55 Fuel Systems Components (Non-Hydrant) R Complete review and update including new Section number and title; Superseding UFGS 33 57 00 BULK FUEL RECEIVING/ DISPENSING EQUIPMENT (Aug-11); Preparing Activity changed from Army to Navy
Nov-2018 A UFGS 33 59 00 Tightness Testing of Existing Underground Fuel Systems D Section is outdated and no longer used. Archived; no replacement.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2018 N UFGS 33 65 00 Cleaning Petroleum Storage Tanks D Superseded by UFGS 33 01 50.60 CLEANING OF PETROLEUM STORAGE TANKS.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.