Below is a listing of the Revisions and Changes made to UFGS Sections for each release. You can narrow the list by selecting a UFGS Release date from the drop-down and clicking 'Apply'.
| KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA [ARCHIVED] |
|---|---|---|---|---|---|
| ACTION | N New | R Revision | C Change | D Deletion |
| Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
|---|---|---|---|---|---|---|
| Aug-2015 | N | UFGS 23 52 53.00 20 Steam Boilers and Equipment (18,000,000 - 60,000,000 BTU/HR) | Apr-2006 | C | 1 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 54 19 Building Heating Systems, Warm Air | Nov-2008 | C | 1 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 64 00 Packaged Water Chillers, Absorption Type | Aug-2009 | C | 1 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 64 10 Water Chillers, Vapor Compression Type | Aug-2008 | C | 3 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems | Aug-2009 | C | 3 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 65 00 Cooling Towers and Remote Evaporatively-Cooled Condensers | Aug-2008 | C | 1 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 69 00.00 20 Refrigeration Equipment for Cold Storage | Jul-2006 | C | 1 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | A | UFGS 23 71 19 Thermal Energy Storage System: Ice-On-Coil | Jan-2008 | C | 1 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 76 00.00 20 Evaporative Cooling System | Jul-2006 | C | 1 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 81 00.00 20 Unitary Air Conditioning Equipment | Nov-2009 | C | 2 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 81 23.00 20 Computer Room Air Conditioning Units | Feb-2010 | C | 1 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 81 47 Water-Loop and Ground-Loop Heat Pump Systems | Aug-2008 | C | 2 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 23 82 00.00 20 Terminal Heating Units | Nov-2008 | C | 2 | UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements". |
| Aug-2015 | N | UFGS 31 23 00.00 20 Excavation and Fill | Feb-2011 | C | 2 | In response to CCR 4371: reference update |
| Aug-2015 | N | UFGS 33 05 23 Trenchless Utility Installation | Aug-2015 | N | New UFGS Section; Superseding UFGS 33 05 23.19 Trenchless Excavating using Microtunneling | |
| Aug-2015 | A | UFGS 33 05 23.19 Trenchless Excavation Using Microtunneling | Apr-2006 | D | Superseded by UFGS 33 05 23 Trenchless Utility Installation; Nontechnical number and title change Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Aug-2015 | N | UFGS 33 56 13.13 Steel Tanks With Fixed Roofs | Aug-2015 | R | UFGS has been revised throughout. Modifications included references, submittals, new jet fuels and requirements for the following in accordance with the update of DoD Aboveground Storage Tank Standard AW 78-24-27: columns, pressure/vacuum vents, antirotation cables, center roof vents, roof manholes, roof circulation vent/inspection hatches, water draw-off systems, sidestream filtration systems, weld inspections and stilling wells. | |
| Aug-2015 | N | UFGS 33 56 13.15 Undertank Interstitial Space | Aug-2015 | R | UFGS has been revised throughout. Modifications included references and requirements for the following in accordance with the update of DoD Aboveground Storage Tank Standard AW 78-24-27: geotextile fabric, geotextile filter fabric and sand cushions. | |
| May-2015 | N | UFGS 01 32 16.00 20 Small Project Construction Progress Schedules | Feb-2015 | C | 1 | Administrative changes to use of "must." Modified Monthly Network Analysis and Contract Administration paragraphs. |
| May-2015 | N | UFGS 01 32 17.00 20 Cost-Loaded Network Analysis Schedules (NAS) | Feb-2015 | C | 1 | Administrative changes to use of "must." Modified Monthly Network Analysis and Contract Administration paragraphs. |
| May-2015 | S | UFGS 01 33 00 Submittal Procedures | May-2011 | C | 6 | Subpart 1.2.1, under SD-11, deleted the mention of DD Form 1354; Subpart 1.4.7, corrected typo, changed tittle to Sustainability Reporting Submittals (S), revised the 1st and 2nd paragraph ; added Sub[art 1.6.10, 1.6.10.1 and 1.6.11; Subpart 1.11.1, revised paragraph; added paragraph "j." to Subpart 1.11.3; Subpart 1.13, added the word "Contract" prior to the word clause, entitled "Changes.". |
| May-2015 | A | UFGS 01 45 00.00 10 Quality Control | Feb-2010 | C | 1 | Add requirements to coordinate with Section 01 45 35 SPECIAL INSPECTIONS |
| May-2015 | A | UFGS 01 50 00 Temporary Construction Facilities and Controls | Aug-2009 | C | 2 | CCR 4158: Updated Fencing Paragraph a. to height requirements in EM 385-1-1. |
| May-2015 | A | UFGS 01 74 19 Construction Waste Management and Disposal | Jan-2007 | C | 2 | Revised required diversion to 60% |
| May-2015 | S | UFGS 01 75 00 Starting and Adjusting | May-2012 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 01 75 00.00 40 with no title change. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | S | UFGS 01 75 00.00 40 Starting and Adjusting | May-2015 | R | NASA reclassified this as fifth level; renumbered May 2012 version of UFGS 01 75 00 with same title; incorporated Non-Technical CCR 4149 in Subpart 1.2.1. | |
| May-2015 | A | UFGS 01 78 00 Closeout Submittals | Aug-2011 | C | 1 | Incorporates multiple approved CCRs. |
| May-2015 | S | UFGS 03 41 16.08 Precast Concrete Slabs (MAX. SPAN 8 FEET O.C.) | May-2015 | R | Title was changed from PRECAST CONCRETE SLABS (MAX. SPAN 8'- 0" O.C.) because the double quotation marks can throw off the SI Tailoring Options Export feature; performed Tri-Annual Database Maintenance (TADM). |
|
| May-2015 | A | UFGS 05 21 00 Steel Joist Framing | May-2015 | N | Consolidate related sections. New UFGS superseding UFGS 05 21 13 Deep Longspan Steel Joist Framing, UFGS 05 21 16 Longspan Steel Joist Framing, UFGS 05 21 19 Open Web Steel Joist Framing, and UFGS 05 21 23 Steel Joist Girder Framing | |
| May-2015 | A | UFGS 05 21 13 Deep Longspan Steel Joist Framing | Aug-2009 | D | Superseded by UFGS 05 21 00 Steel Joist Framing. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | A | UFGS 05 21 16 Longspan Steel Joist Framing | Aug-2009 | D | Superseded by UFGS 05 21 00 Steel Joist Framing. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | N | UFGS 05 21 19 Open Web Steel Joist Framing | Jul-2007 | D | Superseded by UFGS 05 21 00 Steel Joist Framing. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | N | UFGS 05 21 23 Steel Joist Girder Framing | Jul-2007 | D | Superseded by UFGS 02-21 00 Steel Joist Framing. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | N | UFGS 05 30 00 Steel Decks | May-2015 | R | Major revisions to comply with IBC 2012 | |
| May-2015 | N | UFGS 05 40 00 Cold-Formed Metal Framing | May-2015 | R | Major revisions to comply with IBC 2012 | |
| May-2015 | N | UFGS 22 05 48.00 20 Mechanical Sound, Vibration, and Seismic Control | Apr-2006 | C | 1 | CCR 985 and CCR 2715: Revised technical note in subpart 1.4.5 by deleting UFC 3-450-02 and replacing P-355 with UFC 3-310-04. Revised technical note in subparts 1.4.6, 1.4.6.2, and Part 2 by replacing DM 3.10 with UFC 3-450-01. |
| May-2015 | N | UFGS 23 22 26.00 20 Steam System and Terminal Units | Feb-2010 | C | 1 | CCR 2840 - removed technical note in subpart 2.6 |
| May-2015 | S | UFGS 23 37 13.00 40 Diffusers, Registers, and Grills | May-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2015 | N | UFGS 23 52 43.00 20 Low Pressure Water Heating Boilers (Under 800,000 BTU/HR Output) | May-2015 | R | Revised throughout to incorporate CCRs 1006, 4267, and 2584. Modifications included references, boiler installation requirements, detail drawings, water analysis, safety standards, submittals, efficiency requirements, general requirements, controls, safety features, operational tests, and acceptance operational test and inspection. | |
| May-2015 | N | UFGS 23 52 46.00 20 Low Pressure Water Heating Boilers (Over 800,000 BTU/HR Output) | May-2015 | R | Revised throughout to incorporate CCRs 1007 and 4266. Modifications included references, boiler installation requirements, detail drawings, water analysis, safety standards, submittals, controls, safety features, operational tests, and acceptance operational test and inspection. | |
| May-2015 | N | UFGS 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems | Aug-2009 | C | 2 | Modified subparts 2.2.2, 2.2.2.4, 2.6.3, and 3.1.4.4 to show grooved connections are not used on NAVFAC projects. |
| May-2015 | A | UFGS 26 09 13 Power Monitoring System | Nov-2008 | D | Retired; outdated technology, Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | N | UFGS 26 23 00 Low Voltage Switchgear | May-2015 | R | This is a "REVISED" guide specification section number that, in part, replaces the original UFGS 26 23 00 Switchboards and Switchgear. The original guide specification was separated into two specifications: UFGS 26 23 00 Low Voltage Switchgear, and UFGS 26 24 13 Switchboards. This section has had a complete technical update. | |
| May-2015 | N | UFGS 26 24 13 Switchboards | May-2015 | N | This is a "NEW" guide specification section number that, in part, replaces UFGS 26 23 00 Switchboards and Switchgear. The original guide specification was separated into two specifications: UFGS 26 23 00, Low Voltage Switchgear and UFGS 26 24 13 Switchboards, and both sections have also had a complete technical update. | |
| May-2015 | N | UFGS 26 31 00 Facility-Scale Solar Photovoltaic (PV) Systems | May-2015 | N | New section | |
| May-2015 | A | UFGS 27 05 13.00 10 Two-Way Radio Data Ethernet Transmission System | Apr-2006 | D | Retired; outdated technology. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | A | UFGS 27 33 30.00 10 Stand-Alone One-Way Radio Control System | Apr-2006 | D | Retired; outdated technology. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | A | UFGS 27 33 31.00 10 One-Way FM Radio Data Control System | Apr-2006 | D | Retired; outdated technology. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | A | UFGS 27 51 13.00 10 Radio Paging System | Apr-2006 | D | Retired; outdated technology. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | A | UFGS 33 56 19 Fuel Impermeable Liner System | May-2015 | N | Superseding UFGS 33 56 63 Fuel Impermeable Liner System; Complete review and update | |
| May-2015 | A | UFGS 33 56 63 Fuel Impermeable Liner System | Apr-2006 | D | Superseded by UFGS 33 56 19 Fuel Impermeable Liner System. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2015 | N | UFGS 48 14 13.00 20 Solar Liquid Flat Plate and Evacuated Tube Collectors | May-2015 | R | Title changed from SOLAR LIQUID FLAT PLATE COLLECTORS. Section revised throughout. Incorporated evacuated tube collectors. Modifications included in Technical Notes, references and submittals. | |
| Feb-2015 | N | INACTIVE-UFGS 09 97 13.15 Low VOC Polysulfide Interior Coating of Welded Steel Petroleum Fuel Tanks | Feb-2015 | R | Title changed from EPOXY/FLUOROPOLYURETHANE INTERIOR COATING OF WELDED STEEL PETROLEUM FUEL TANKS; This spec is a complete revision to reflect a new and different product. The spec was modified to move from Epoxy/ Fluoropolyurethane products to low VOC polysulfide modified novolac epoxy. Updates to reporting requirements were also added. | |
| Feb-2015 | A | UFGS 01 32 01.00 10 Project Schedule | Feb-2015 | R | Complete Section review and refresh | |
| Feb-2015 | N | UFGS 01 32 16.00 20 Small Project Construction Progress Schedules | Feb-2015 | R | Title changed from CONSTRUCTION PROGRESS DOCUMENTATION; thoroughly revised Schedule Format, Schedule Monthly Updates, and Contract Modification. | |
| Feb-2015 | N | UFGS 01 32 17.00 20 Cost-Loaded Network Analysis Schedules (NAS) | Feb-2015 | R | Title changed from NETWORK ANALYSIS SCHEDULES (NAS); thoroughly revised to Primavera P6, Updated WBS & Activity Codes and Settings. | |
| Feb-2015 | S | UFGS 01 33 00 Submittal Procedures | May-2011 | C | 5 | Per USACE request, adjusted the Note in the following subparts, 1.4.1, 1.4.3, 1.11.4, to let the designers know they can only use the wording in the Model RFP for guidance but can't get the file, Section 01 33 16 Design After Award is not a UFGS Section. |
| Feb-2015 | N | UFGS 01 33 29 Sustainability Requirements and Reporting | Feb-2015 | R | Title changed from SUSTAINABILITY REQUIREMENTS to comply with CSI MasterFormat; Coordination with criteria and corrections throughout section. | |
| Feb-2015 | N | UFGS 01 45 00.00 20 Quality Control | Nov-2011 | C | 1 | Updated to conform to the DOD Special Inspection requirements defined in spec 01 45 35; Added Special Inspections requirements and removed references to LEED. |
| Feb-2015 | A | UFGS 01 45 35 Special Inspections | Feb-2015 | R | Complete Section review and refresh. | |
| Feb-2015 | N | UFGS 01 57 19.00 20 Temporary Environmental Controls | Nov-2011 | C | 2 | Modified subpart 3.1.1.3 |
| Feb-2015 | A | UFGS 01 62 35 Recycled / Recovered / Biobased Materials | May-2013 | D | Superseded by UFGS 01 33 29 SUSTAINABILITY REPORTING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2015 | N | UFGS 01 78 23 Operation and Maintenance Data | Jul-2006 | C | 3 | Added Safety Hazards, Operating Log, Extended Warranty and Field Test Reports to O&M DATA PACKAGES. Coordinated with UFGS 01 78 24.00 20 Facility eOMSI . |
| Feb-2015 | N | UFGS 01 78 24.00 20 Facility Data Workbook (FDW) | Feb-2015 | R | Deleted eOMSI manual for Primary Systems; incorporated requirements into other manuals. Coordinated FACILITY INFORMATION in this section with Section 01 78 23. Updated Record Drawing. | |
| Feb-2015 | S | UFGS 01 83 00.07 40 Reliability Centered Acceptance for Facility Shells | Feb-2012 | C | 1 | Consist of imperative language, spell check, QC reports, and formatting review. |
| Feb-2015 | S | UFGS 01 83 13.07 40 Reliability Centered Acceptance for Superstructure Performance Requirements | Feb-2012 | C | 1 | Consist of imperative language, spell check, QC reports, and formatting review. |
| Feb-2015 | S | UFGS 01 86 12.07 40 Reliability Centered Acceptance for Mechanical Systems | Feb-2012 | C | 1 | Consist of imperative language, spell check, QC reports, and formatting review. |
| Feb-2015 | S | UFGS 01 86 26.07 40 Reliability Centered Acceptance for Electrical Systems | Feb-2012 | C | 1 | Consist of imperative language, spell check, QC reports, and formatting review. |
| Feb-2015 | S | UFGS 02 42 51 Carpet Removal and Reclamation | Feb-2012 | C | 1 | Consist of imperative language, spell check, QC reports, and formatting review. |
| Feb-2015 | N | UFGS 03 30 00 Cast-In-Place Concrete | May-2014 | C | 1 | Completion of Criteria Change Request. |
| Feb-2015 | A | UFGS 03 30 00.00 10 Cast-In-Place Concrete | May-2014 | C | 1 | Response to CCR 3916. |
| Feb-2015 | S | UFGS 05 72 00 Decorative Metal Specialties | Feb-2012 | C | 1 | Consist of imperative language, spell check, QC reports, and formatting review . |
| Feb-2015 | S | UFGS 06 71 33 Fiberglass Reinforced Plastic (FRP) Ladders | Feb-2015 | R | Tri Annual Database Maintenance (TADM) completed. | |
| Feb-2015 | S | UFGS 06 73 01 Fiberglass Reinforced Plastic (FRP) Grating | Feb-2015 | R | Tri Annual Database Maintenance (TADM) completed. | |
| Feb-2015 | S | UFGS 06 82 14 Fiberglass Reinforced Plastic (FRP) Pipe and Tube Railings | Feb-2015 | R | Tri Annual Database Maintenance (TADM) completed. | |
| Feb-2015 | S | UFGS 08 34 73 Sound Control Door Assemblies | Feb-2015 | R | Tri Annual Database Maintenance (TADM) completed. | |
| Feb-2015 | A | UFGS 10 14 53 Traffic Signage | Feb-2015 | N | New UFGS section. | |
| Feb-2015 | A | UFGS 14 92 00 Pneumatic-Tube System | Feb-2009 | C | 1 | Incorporate CCR 3970, adding Energy Star compliance . |
| Feb-2015 | S | UFGS 23 01 30.41 HVAC System Cleaning | Feb-2015 | R | Tri Annual Database Maintenance (TADM) completed. | |
| Feb-2015 | N | UFGS 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC | Aug-2009 | C | 1 | Completion of Criteria Change Request. |
| Feb-2015 | N | UFGS 23 82 00.00 20 Terminal Heating Units | Nov-2008 | C | 1 | Completion of Criteria Change Request . |
| Feb-2015 | S | UFGS 26 05 70.00 40 High-Voltage Overcurrent Protective Devices | Feb-2015 | R | Tri Annual Database Maintenance (TADM) completed. | |
| Feb-2015 | N | UFGS 26 08 00 Apparatus Inspection and Testing | Aug-2008 | C | 1 | Modified subpart 3.1 e. |
| Feb-2015 | A | UFGS 31 31 16.21 Mesh Termite Barrier | Aug-2008 | D | Superseded by UFGS 31 31 16.19 MESH TERMITE CONTROL BARRIER SYSTEM. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2015 | N | UFGS 33 47 13 Pond and Reservoir Liners | Nov-2014 | C | 1 | Reference update; added subparts 2.1.3, 2.1.4, 2.1.5, and 2.1.6; technical updates to subparts 3.3, 3.6, 3.7.1.2.1, and 3.7.1.2.2 |
| Feb-2015 | N | UFGS 33 71 02 Underground Electrical Distribution | Feb-2015 | R | The UFGS has been revised through-out. Modifications include updates to references and clarifications of requirements and applications of materials and methods relating to: conduits, conductors, certificates, faulted circuit indicators, fireproofing, handholes, grounding, and duct-banks. | |
| Feb-2015 | A | UFGS 34 71 13.16 Vehicle Crash Barriers | Feb-2015 | N | New UFGS section. | |
| Feb-2015 | A | UFGS 35 01 42.00 10 Vertical Gate Lift Systems | Apr-2008 | D | Superseded by UFGS 35 01 41.00 10 ELECTROMECHANICAL OPERATING MACHINERY FOR LOCKS AND DAMS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Dec-2014 | N | UFGS 31 62 19 Timber Piles | Jan-2008 | C | 2 | Changed Section Reference 00 41 00 BID SCHEDULES to Section Reference 00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO OFFERORS |
| Dec-2014 | N | UFGS 31 62 19 Timber Piles | Jan-2008 | C | 2 | Changed Section Reference 00 41 00 BID SCHEDULES to Section Reference 00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO OFFERORS |
| Nov-2014 | N | UFGS 01 11 00 Summary of Work | Aug-2011 | C | 1 | SRF Update: Replaces 01 35 40.00 20 ENVIRONMENTAL MANAGEMENT with 01 57 19.00 20 TEMPORARY ENVIRONMENTAL CONTROLS. |
| Nov-2014 | S | UFGS 01 33 00 Submittal Procedures | May-2011 | C | 4 | Tri-Annual Database Maintenance (TADM) which consists of updating of Section Format, imperative language and formatting review, and verification of all reports and spelling. |
| Nov-2014 | S | UFGS 01 33 00 Submittal Procedures | May-2011 | C | 4 | Tri-Annual Database Maintenance (TADM), which consists of: Tailoring changes, incorporation of Sustainability requirements, CCR's and verification of all reports and spelling. |
| Nov-2014 | N | UFGS 01 33 29 Sustainability Requirements and Reporting | May-2012 | D | Section titled LEED Documentation replaced/superseded by new UFGS 01 33 29 titled Sustainability Requirements. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2014 | N | UFGS 01 33 29 Sustainability Requirements and Reporting | Nov-2014 | N | New section superseding previous UFGS 01 33 29 titled LEED Documentation and superseding UFGS 01 33 29.00 20 Sustainable Requirements | |
| Nov-2014 | N | UFGS 01 33 29.00 20 Sustainable Requirements | Aug-2013 | D | Superseded by UFGS 01 33 29 Sustainability Requirements. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2014 | N | UFGS 01 35 40.00 20 Environmental Management | Feb-2010 | D | Superseded by UFGS 01 57 19.00 20 Temporary Environmental Controls. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2014 | A | UFGS 01 42 00 Sources for Reference Publications | Nov-2014 | R | Confirmed or updated organization address information. | |
| Nov-2014 | A | UFGS 01 74 19 Construction Waste Management and Disposal | Jan-2007 | C | 1 | Replaced section reference 01 35 40.00 20 with 01 57 19.00 20 TEMPORARY ENVIRONMENTAL CONTROLS. |
| Nov-2014 | N | UFGS 01 78 24.00 20 Facility Data Workbook (FDW) | Aug-2014 | C | 1 | Clarified how to download eOMSI Facility Data Workbook, added reference to Section 01 32 17.00 20, and in 2.3, item e, added Asset number provided by Govt. |