Aug-2009 A UFGS 01 50 00 Temporary Construction Facilities and Controls R Revised USACE Project Sign requirements
Aug-2009 N UFGS 01 58 00 Project Identification R Minor revisions
Aug-2009 N UFGS 03 31 29 Marine Concrete with Service Life Modeling R Major revision
Aug-2009 A UFGS 05 21 13 Deep Longspan Steel Joist Framing R Extensive reformat for conformance with CSI SectionFormat
Aug-2009 A UFGS 05 21 16 Longspan Steel Joist Framing R Extensive reformat for conformance with CSI SectionFormat
Aug-2009 A UFGS 05 59 13 Fabrication of Hydraulic Steel Structures N New section
Aug-2009 A UFGS 06 41 16.00 10 Plastic-Laminate-Clad Architectural Cabinets R Compliance with CSI SectionFormat
Aug-2009 A UFGS 06 61 16 Solid Surfacing Fabrications R Compliance with CSI SectionFormat
Aug-2009 A UFGS 07 31 26 Slate Shingles R Compliance with CSI SectionFormat
Aug-2009 A UFGS 07 55 00 Protected Membrane Roofing (PMR) R Compliance with CSI SectionFormat
Aug-2009 N UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing R Minor revisions
Aug-2009 A UFGS 07 61 01 Copper Roof System R Compliance with CSI SectionFormat
Aug-2009 A UFGS 07 62 10 Copper Sheet Metal Flashing R Compliance with CSI SectionFormat
Aug-2009 A UFGS 07 72 00 Roof Ventilators, Gravity-Type R Compliance with CSI SectionFormat
Aug-2009 A UFGS 08 34 01 Forced Entry Resistant Components R Compliance with CSI SectionFormat
Aug-2009 A UFGS 08 34 02 Bullet-Resistant Components R Compliance with CSI SectionFormat
Aug-2009 A UFGS 08 39 54 Blast Resistant Doors R Compliance with CSI SectionFormat
Aug-2009 N UFGS 08 51 13 Aluminum Windows R Major revision
Aug-2009 A UFGS 08 52 70 Wood Windows - Repair and Rehabilitation R Compliance with CSI SectionFormat
Aug-2009 A UFGS 08 62 00 Skylights R Compliance with CSI SectionFormat
Aug-2009 A UFGS 08 87 16 Fragment Retention Film for Glass R Compliance with CSI SectionFormat
Aug-2009 N UFGS 09 22 00 Supports for Plaster and Gypsum Board R Minor revisions
Aug-2009 N UFGS 09 29 00 Gypsum Board R Minor revisions
Aug-2009 S UFGS 09 90 00.00 40 Painting and Coating D Section merged with UFGS 09 90 00 Paints and Coatings (Preparing Activity: NAVFAC)
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2009 A UFGS 11 13 10 Dock Levelers R Revised SD-10 Operation and Maintenance Data
Aug-2009 N UFGS 22 00 00 Plumbing, General Purpose R Subpart 1.2-Corrected lead para; 2.4.3-added Dual Flush; 2.5-added Regulatory Agencies; 2.10-modified para. & editorial corrections; 2.10.4-updated para. and subpart as, 3.9.1.1-updated para.; 3.9.5-updated para.
Aug-2009 A UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems R Corrections and revision throughout, plus addition of Navy tailoring
Aug-2009 N UFGS 23 05 93 Testing, Adjusting, and Balancing for HVAC R For NAVFAC projects: added notes under Project Drawings and Dalt Procedures, modified para 1.2, 3.4.1, 3.4.8, and 3.7
Aug-2009 N UFGS 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC R Within subpart 2.3.1, deleted third paragraph
Aug-2009 S UFGS 23 09 33.00 40 Electric and Electronic Control System for HVAC R Minor revisions
Aug-2009 S UFGS 23 22 25 Steam Valves R Minor revisions
Aug-2009 N UFGS 23 64 00 Packaged Water Chillers, Absorption Type R Deleted para. 2.5.5
Aug-2009 N UFGS 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems R Editorial changes to subparts 2.3 & 2.4
Aug-2009 A UFGS 26 42 14.00 10 Cathodic Protection System (Sacrificial Anode) R Incorporated CCRs 1174, 1175, 1178, 1181, 1184, and 1185
Aug-2009 A UFGS 28 31 64.00 10 Fire Detection and Alarm System, Addressable R Incorporated CCRs 1499, 1500, 1501, 1502, 1503, 1504, 1505, 1506, 1507, 1509, and 1510
Aug-2009 A UFGS 31 41 16 Metal Sheet Piling R Revised sheet piling section properties
Aug-2009 N UFGS 31 62 13.20 Precast/Prestressed Concrete Piles R Major revision
Aug-2009 A UFGS 32 12 16 Hot-Mix Asphalt (HMA) for Roads R Revised JMF requirements and Tables 7 and 8 revised; changed text to active voice
Aug-2009 A UFGS 33 40 00 Stormwater Utilities R Complete revision of section
Aug-2009 A UFGS 33 82 01 Intercommunication System R Revised SD-10 Operation and Maintenance Data
Aug-2009 N UFGS 35 59 13.13 Prestressed Concrete Fender Piling R Major revision
May-2009 A UFGS 01 42 00 Sources for Reference Publications R National Association of Architectural Metal Manufacturers (NAAMM) address correction
May-2009 A UFGS 01 78 00 Closeout Submittals R Clarified CADD file format
May-2009 S UFGS 02 42 51 Carpet Removal and Reclamation N New section
May-2009 A UFGS 03 11 13.00 10 Structural Cast-In-Place Concrete Forming R Combined section with UFGS 03 11 14.00 10 Formwork for Concrete
May-2009 A UFGS 03 11 14.00 10 Formwork for Concrete D Section has been combined with and superseded by UFGS 03 11 13.00 10 Structural Concrete Formwork
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2009 S UFGS 03 62 16 Metallic Non-Shrink Grouting R General update
May-2009 S UFGS 05 51 00 Metal Stairs R General update
May-2009 S UFGS 05 72 00 Decorative Metal Specialties R General update
May-2009 S UFGS 06 18 00 Glued-Laminated Construction R General update
May-2009 S UFGS 06 71 33 Fiberglass Reinforced Plastic (FRP) Ladders N New section
May-2009 S UFGS 06 82 14 Fiberglass Reinforced Plastic (FRP) Pipe and Tube Railings N New section
May-2009 S UFGS 07 41 63 Fabricated Roof Panel Assemblies R General update
May-2009 A UFGS 08 13 73 Sliding Metal Doors R Compliance with CSI SectionFormat
May-2009 S UFGS 08 22 20 Fiberglass Reinforced Plastic (FRP) Doors and Frames N New section
May-2009 A UFGS 08 33 13 Coiling Counter Doors R Compliance with CSI SectionFormat
May-2009 A UFGS 09 06 90 Schedules for Painting and Coating R Compliance with CSI SectionFormat
May-2009 A UFGS 09 24 23 Cement Stucco R Compliance with CSI SectionFormat
May-2009 A UFGS 09 35 16 Chemical-Resistant Quarry Tiling R Compliance with CSI SectionFormat
May-2009 A UFGS 09 64 23 Wood Parquet Flooring R Compliance with CSI SectionFormat
May-2009 A UFGS 09 65 33 Conductive Vinyl Flooring R Compliance with CSI SectionFormat
May-2009 A UFGS 09 65 66 Resilient Athletic Flooring R Compliance with CSI SectionFormat
May-2009 A UFGS 09 66 13 Portland Cement Terrazzo Flooring R Compliance with CSI SectionFormat
May-2009 A UFGS 09 66 16 Terrazzo Floor Tile R Compliance with CSI SectionFormat
May-2009 A UFGS 09 66 23 Resinous Matrix Terrazzo Flooring R Compliance with CSI SectionFormat
May-2009 A UFGS 09 83 13 Acoustical Wall Coating R Compliance with CSI SectionFormat
May-2009 A UFGS 09 97 01.00 10 Metallizing Hydraulic Structures R Compliance with CSI SectionFormat
May-2009 A UFGS 09 97 02 Painting: Hydraulic Structures R Compliance with CSI SectionFormat
May-2009 A UFGS 09 97 30 Preparation of Historic Wood and Metal Surfaces for Painting R Compliance with CSI SectionFormat
May-2009 A UFGS 10 22 19 Demountable and Moveable Partitions R Compliance with CSI SectionFormat
May-2009 A UFGS 10 26 13 Wall and Corner Guards R Compliance with CSI SectionFormat
May-2009 S UFGS 10 44 16 Fire Extinguishers R General update
May-2009 S UFGS 12 31 00 Manufactured Metal Casework R General update
May-2009 S UFGS 12 32 00 Manufactured Wood Casework R General update
May-2009 S UFGS 12 34 00 Manufactured Plastic Casework R General update
May-2009 S UFGS 12 36 00 Countertops R General update
May-2009 S UFGS 12 48 13.13 Entrance Floor Mats R General update
May-2009 A UFGS 21 13 13.00 10 Wet Pipe Sprinkler System, Fire Protection R Revised Paragraph DISINFECTION
May-2009 A UFGS 21 13 17.00 10 Dry Pipe Sprinkler System, Fire Protection R Revised Paragraph DISINFECTION
May-2009 A UFGS 21 13 18.00 10 Preaction and Deluge Sprinkler Systems, Fire Protection R Revised Paragraph DISINFECTION
May-2009 A UFGS 22 00 70 Plumbing for Healthcare Facilities R Revised Paragraph COPPER-SILVER IONIZATION SYSTEM
May-2009 A UFGS 22 60 70 Gas and Vacuum Systems for Healthcare Facilities R Added Special Fittings to Paragraph PIPE AND FITTINGS
May-2009 S UFGS 31 63 29 Drilled Concrete Piers and Shafts N New section
May-2009 A UFGS 32 11 29 Lime-[Stabilized] [Modified] Subgrade R Title changed from Lime-Stabilized Base Course, Subbase, or Subgrade and revisions to comply with UFC 3-250-11
May-2009 A UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields R Added Marshall Compaction Requirements
May-2009 S UFGS 32 31 13 Chain Link Fences and Gates R General update
May-2009 S UFGS 33 01 99 Slip Lining of Existing Piping N New section
May-2009 S UFGS 33 01 99 Slip Lining of Existing Piping N New section
May-2009 S UFGS 33 32 13.13 Packaged Sewage Lift Stations, Wet Well Type R General update
May-2009 A UFGS 41 65 10.00 10 [Diesel] [Natural Gas] Fueled Engine Pump Drives R Tailored for Diesel and Natural Gas
Feb-2009 S UFGS 01 33 00 Submittal Procedures R Updated Standard Submittal Note
Feb-2009 N UFGS 01 35 26 Governmental Safety Requirements R Added 1.6.1.2
Feb-2009 N UFGS 01 57 19.00 20 Temporary Environmental Controls R Revised 1.4.1
Feb-2009 A UFGS 04 20 00 Unit Masonry R Revised 2.17 Insulation
Feb-2009 A UFGS 07 81 00 Spray-Applied Fireproofing R Compliance with CSI SectionFormat
Feb-2009 N UFGS 08 81 00 Glazing R Revised 2.1.8.1
Feb-2009 A UFGS 09 65 00 Resilient Flooring R General update
Feb-2009 A UFGS 10 10 00 Visual Communications Specialties R Compliance with CSI SectionFormat
Feb-2009 A UFGS 10 14 02 Interior Signage R General update
Feb-2009 A UFGS 11 47 00 Ice Machines R Compliance with CSI SectionFormat