Below is a listing of the Revisions and Changes made to UFGS Sections for each release. You can narrow the list by selecting a UFGS Release date from the drop-down and clicking 'Apply'.
| KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA [ARCHIVED] |
|---|---|---|---|---|---|
| ACTION | N New | R Revision | C Change | D Deletion |
| Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
|---|---|---|---|---|---|---|
| May-2018 | A | UFGS 23 82 02.00 10 Unitary Heating and Cooling Equipment | Apr-2008 | D | Superseded by UFGS 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | N | UFGS 26 12 19 Pad-Mounted, Liquid-Filled, Medium Voltage Transformers | May-2017 | C | 1 | Change incorporates minor corrections and coordinates the use of Non-mineral insulating oil. |
| May-2018 | A | UFGS 31 32 11 Soil Surface Erosion Control | Aug-2008 | D | The information contained in this UFGS is duplicated and more updated in other specifications. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | A | UFGS 32 01 13.62 Bituminous Surface Treatment [and] [Sand Seal] | May-2018 | N | Superseding UFGS 32 12 11 BITUMINOUS SURFACE TREATMENT. Complete review and update including section number and title changes. | |
| May-2018 | A | UFGS 32 01 16.70 Cold-Mix Reused Asphalt Paving | May-2018 | N | Superseding UFGS 32 01 17 COLD-MIX RECYCLING. Complete review and update including section number and title changes. | |
| May-2018 | A | UFGS 32 01 16.74 In Place Hot Reused Asphalt Paving | May-2018 | N | Superseding UFGS 32 01 24 HOT IN-PLACE RECYCLING OF BITUMINOUS PAVEMENT. Complete review and update including section number and title changes. | |
| May-2018 | A | UFGS 32 01 17 Cold-Mix Recycling | Aug-2008 | D | Superseded by UFGS 32 01 16.70 COLD-MIX REUSED ASPHALT PAVING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | A | UFGS 32 01 24 Hot In-Place Recycling of Bituminous Pavements | Aug-2008 | D | Superseded by UFGS 32 01 16.74 IN PLACE HOT REUSED ASPHALT PAVING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | N | UFGS 32 11 16.13 Sand-Clay [Base] [Subbase] Course | Apr-2006 | D | Outdated specification; No longer used. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | N | UFGS 32 11 16.16 [Base Course for Rigid] [and Subbase Course for Flexible] [Subbase Course for Pervious] Paving | Nov-2011 | D | Superseded by Section 32 11 20 [BASE COURSE FOR RIGID][ AND ][SUBBASES FOR FLEXIBLE] PAVING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | N | UFGS 32 11 24 Graded Crushed Aggregate Base Course for [Pervious] [Flexible] Pavement | Nov-2011 | D | Superseded by Section 32 11 20 [BASE COURSE FOR RIGID][ AND ][SUBBASES FOR FLEXIBLE] PAVING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | N | UFGS 32 11 26.16 Bituminous Concrete Base Course | Apr-2006 | D | Outdated specification; No longer used. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | A | UFGS 32 12 11 Bituminous Surface Treatment | Nov-2008 | D | Superseded by UFGS 32 01 13.62 ASPHALT SURFACE TREATMENT. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | N | UFGS 32 12 17 Hot Mix Bituminous Pavement | Apr-2008 | D | Superseded by Section 32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | A | UFGS 32 16 13 Concrete Sidewalks and Curbs and Gutters | Apr-2008 | D | Superseded by UFGS 32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | A | UFGS 32 16 19 Concrete Curbs, Gutters and Sidewalks | May-2018 | N | Superseding UFGS 32 16 13 CONCRETE SIDEWALKS AND CURBS AND GUTTERS. Complete review and update including section number and title changes. | |
| May-2018 | A | UFGS 33 30 00 Sanitary Sewerage | May-2018 | R | Complete review and update including section title name from SANITARY SEWERS. | |
| May-2018 | A | UFGS 33 46 16 Subdrainage Piping | May-2018 | R | Complete review and update. | |
| May-2018 | A | UFGS 35 05 40.17 Self-Lubricated Materials, Fabrication, Handling, and Assembly | May-2014 | C | 1 | Incorporated changes in response to CCR 4572. |
| May-2018 | A | UFGS 43 31 14 Trickling Filter | Apr-2006 | D | Superseded by UFGS 46 53 22 TRICKLING FILTER. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2018 | A | UFGS 46 53 22 Trickling Filter | May-2018 | N | Superseding UFGS 43 31 14 TRICKLING FILTER. Complete review and update including section number change. | |
| Feb-2018 | N | UFGS 01 35 26 Governmental Safety Requirements | Nov-2015 | C | 6 | In response to CCR 5966, Note in para 1.6.1 has been updated to include Hawaii; in response to CCR 6077, item "e" under para 3.7.1 "Scaffolding" has been corrected. |
| Feb-2018 | S | UFGS 01 83 00.07 40 Reliability Centered Acceptance for Facility Shells | Feb-2018 | R | Tri-Annual Database Maintenance (TADM) completed. | |
| Feb-2018 | S | UFGS 01 83 00.07 40 Reliability Centered Acceptance for Facility Shells | Feb-2018 | R | Tri-Annual Database Maintenance - Subpart 1.3 SUBMITTALS, minor revision | |
| Feb-2018 | S | UFGS 01 83 13.07 40 Reliability Centered Acceptance for Superstructure Performance Requirements | Feb-2018 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2018 | S | UFGS 01 83 13.07 40 Reliability Centered Acceptance for Superstructure Performance Requirements | Feb-2018 | R | Tri-Annual Database Maintenance - Subpart 1.3 SUBMITTALS, minor revision | |
| Feb-2018 | S | UFGS 01 86 12.07 40 Reliability Centered Acceptance for Mechanical Systems | Feb-2018 | R | Tri-Annual Database Maintenance - Subpart 1.3 SUBMITTALS, minor revision | |
| Feb-2018 | S | UFGS 01 86 12.07 40 Reliability Centered Acceptance for Mechanical Systems | Feb-2018 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2018 | S | UFGS 01 86 26.07 40 Reliability Centered Acceptance for Electrical Systems | Feb-2018 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2018 | S | UFGS 01 86 26.07 40 Reliability Centered Acceptance for Electrical Systems | Feb-2018 | R | Tri-Annual Database Maintenance -Subpart 1.3 SUBMITTALS, minor revision | |
| Feb-2018 | A | UFGS 03 01 00 Rehabilitation of Concrete | Feb-2018 | N | Superseding UFGS 03 01 30 RESTORATION OF CONCRETE IN HISTORIC STRUCTURES and 03 01 32 CONCRETE REHABILITATION FOR CIVIL WORKS. Complete review and update including section number and title changes. | |
| Feb-2018 | A | UFGS 03 01 30 Restoration of Concrete in Historic Structures | Nov-2009 | D | Superseded by UFGS 03 01 00 REHABILITATION OF CONCRETE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2018 | A | UFGS 03 01 32 Concrete Rehabilitation for Civil Works | Nov-2009 | D | Superseded by UFGS 03 01 00 REHABILITATION OF CONCRETE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2018 | A | UFGS 03 37 13 Shotcrete | Feb-2018 | R | Complete review and update. | |
| Feb-2018 | S | UFGS 03 62 16 Metallic Non-Shrink Grouting | Feb-2018 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2018 | S | UFGS 03 62 16 Metallic Non-Shrink Grouting | Feb-2018 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2018 | S | UFGS 03 62 16 Metallic Non-Shrink Grouting | Feb-2018 | R | Tri-Annual Database Maintenance - Subpart 1.2 Submittal Article Compliance; minor revisions 1.3, 2.2, 2.4 | |
| Feb-2018 | N | UFGS 05 51 33 Metal Ladders | Feb-2016 | C | 2 | Incorporated the changes from the final rule 29 CFR 1910 (Nov 2016) affecting phasing out cages installed on fixed ladders |
| Feb-2018 | S | UFGS 05 52 00 Metal Railings | Feb-2018 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2018 | S | UFGS 05 52 00 Metal Railings | Feb-2018 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2018 | N | UFGS 07 14 00 Fluid-Applied Waterproofing | Feb-2012 | C | 2 | In response to CCR 5945 |
| Feb-2018 | N | UFGS 07 21 16 Mineral Fiber Blanket Insulation | Nov-2011 | C | 3 | In response to CCR 2219 reference for recycled materials added. |
| Feb-2018 | N | UFGS 07 24 00 Exterior Insulation and Finish Systems | May-2011 | C | 3 | In response to CCRs 2225, 2226, 2227, and 2228 |
| Feb-2018 | N | UFGS 07 42 13 Metal Wall Panels | May-2011 | C | 2 | In response to CCR 3731 |
| Feb-2018 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | May-2011 | C | 3 | In response to CCRs 1529 and 3187 |
| Feb-2018 | N | UFGS 08 56 46.20 20 Radio Frequency Shielded Enclosures, Welded Type | Aug-2011 | C | 1 | In response to CCR 1700 |
| Feb-2018 | N | UFGS 08 91 00 Metal [Wall] [and] [Door] Louvers | May-2011 | C | 1 | In response to CCRs 2409 and 3191 |
| Feb-2018 | A | UFGS 10 26 00 Wall and Door Protection | Aug-2017 | C | 1 | In response to CCR 6149, replaced ASTM A167 references with ASTM A240/A240M |
| Feb-2018 | N | UFGS 11 05 40 Common Work Results for Foodservice Equipment | Aug-2017 | C | 2 | In response to CCR 3364 |
| Feb-2018 | N | UFGS 13 34 19 Metal Building Systems | Nov-2011 | C | 2 | In response to CCRs 1904 and 4945 |
| Feb-2018 | A | UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems | Aug-2010 | C | 6 | Added pressure test requirements for coils to paragraph 2.12.2. |
| Feb-2018 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Feb-2013 | C | 3 | In response to CCR 5445, added note to paragraph 3.2.1.6 for NAVFAC MAR Projects |
| Feb-2018 | A | UFGS 23 72 26.00 10 Desiccant Cooling Systems | Apr-2008 | D | Superseded by UFGS 23 84 19.00 DESICCANT COOLING SYSTEMS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2018 | N | UFGS 23 84 16.00 20 Desiccant Dehumidification Equipment | Feb-2011 | D | Superseded by new UFGS Section 23 84 19.00 DESICCANT COOLING SYSTEMS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2018 | A | UFGS 23 84 19.00 Desiccant Cooling Systems | Feb-2018 | N | Superseding UFGS 23 72 26.00 10 DESICCANT COOLING SYSTEMS. Complete review and update with section number change. | |
| Feb-2018 | N | UFGS 26 35 43 400-Hertz (HZ) Solid State Frequency Converter | May-2011 | C | 2 | Changes were made to align with manufacturers standard products. |
| Feb-2018 | N | UFGS 26 35 44.00 20 270 VDC Solid State Ground Power Unit | Feb-2018 | N | New UFGS required for supporting new aircraft types. | |
| Feb-2018 | A | UFGS 32 12 15.16 Stone Matrix Asphalt (SMA) for Airfield Paving | Nov-2012 | D | Section is no longer active. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2018 | A | UFGS 32 12 21 Bituminous Road-Mix Surface Course | Aug-2008 | D | UFGS archived. UFGS is no longer active. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2018 | N | UFGS 32 13 13.43 High Temperature Concrete Paving for Airfields Using Lightweight and Traprock Aggregates | Feb-2018 | N | New UFGS Section | |
| Feb-2018 | N | UFGS 33 11 00 Water Utility Distribution Piping | Feb-2018 | R | Complete revision of this section | |
| Feb-2018 | N | UFGS 35 59 13.14 20 Polymeric Piles | Feb-2018 | R | Section revised to address rapid changes and advancements in the composite industry. Title changed from POLYMERIC FENDER PILES. | |
| Nov-2017 | N | UFGS 01 33 29 Sustainability Requirements and Reporting | Feb-2017 | C | 2 | Changes are related to Change 01 UFC 1-200-02, and updates. |
| Nov-2017 | N | UFGS 01 35 26 Governmental Safety Requirements | Nov-2015 | C | 5 | Addition of lockout/tagout requirements when the Government of Utility is involved in the electrical outage |
| Nov-2017 | S | UFGS 01 45 00.00 40 Quality Control | Nov-2017 | R | Tri-Annual Database Maintenance (TADM) completed. | |
| Nov-2017 | S | UFGS 01 45 00.00 40 Quality Control | Nov-2017 | R | Tri-Annual Database Maintenance (TADM) completed. | |
| Nov-2017 | S | UFGS 01 45 00.00 40 Quality Control | Nov-2017 | R | Tri-Annual Database Maintenance | |
| Nov-2017 | A | UFGS 01 78 00 Closeout Submittals | Aug-2011 | C | 3 | Incorporated administrative changes changes in response to CCR 5943. |
| Nov-2017 | A | UFGS 04 01 20.70 Unit Masonry Cleaning and Restoration | Nov-2015 | D | Superseded by UFGS 04 03 00 CONSERVATION TREATMENT FOR PERIOD MASONRY. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2017 | A | UFGS 04 03 00 Conservation Treatment for Period Masonry | Nov-2017 | N | Superseding UFGS 04 01 20.70 UNIT MASONRY CLEANING AND RESTORATION. Reviewed for currency, revised title. | |
| Nov-2017 | N | UFGS 08 71 00 Door Hardware | Feb-2016 | C | 1 | In response to CCR 5837 , removed paragraph pertaining to Navy Training Center , Orlando , Florida . |
| Nov-2017 | A | UFGS 09 68 00 Carpeting | Nov-2017 | R | Complete review and update. | |
| Nov-2017 | N | UFGS 11 53 00 Laboratory Equipment and Fumehoods | May-2011 | C | 1 | In response to CCR 3026, reference ACGIH-2092S was replaced with ACGIH-2097. |
| Nov-2017 | N | UFGS 22 00 00 Plumbing, General Purpose | Nov-2015 | C | 2 | In response to CCR 5954, updated Table I to include condensate drain piping. |
| Nov-2017 | S | UFGS 22 15 13.16 40 High-Pressure Compressed-Air Piping and Valves, Stainless | Nov-2017 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Nov-2017 | S | UFGS 22 15 13.16 40 High-Pressure Compressed-Air Piping and Valves, Stainless | Nov-2017 | R | Tri-Annual Database Maintenance (TADM) completed. | |
| Nov-2017 | S | UFGS 22 15 14.00 40 General Service Compressed-Air Systems, Low Pressure | Nov-2017 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Nov-2017 | S | UFGS 22 15 14.00 40 General Service Compressed-Air Systems, Low Pressure | Nov-2017 | R | Tri-Annual Database Maintenance (TADM) completed. | |
| Nov-2017 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Feb-2013 | C | 2 | Added new paragraphs 2.4.1.4 and 2.4.2.7 per Mechanical DWG. |
| Nov-2017 | A | UFGS 23 09 00 Instrumentation and Control for HVAC | Nov-2015 | C | 1 | Updated tailoring option for Navy jobs with an Acceptance Engineer. |
| Nov-2017 | S | UFGS 23 22 25.00 40 Steam Valves | Nov-2017 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Nov-2017 | S | UFGS 23 22 25.00 40 Steam Valves | Nov-2017 | R | Tri-Annual Database Maintenance (TADM) completed. | |
| Nov-2017 | A | UFGS 25 05 11 Cybersecurity for Facility-Related Control Systems | Nov-2017 | N | New UFGS section. | |
| Nov-2017 | S | UFGS 26 23 00.00 40 Switchboards and Switchgear | Nov-2017 | R | Tri- Annual Database Maintenance (TADM) completed. | |
| Nov-2017 | S | UFGS 26 52 00.00 40 Emergency Lighting | Nov-2017 | R | Tri-Annual Database Maintenance (TADM) completed. | |
| Nov-2017 | S | UFGS 26 56 23.00 40 Area Lighting | Nov-2008 | D | Section retired. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2017 | A | UFGS 32 12 15.13 Asphalt Paving for Airfields | Nov-2017 | R | Complete review and update including section title change. | |
| Nov-2017 | A | UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements | Nov-2015 | D | Superseded by UFGS 32 13 14.13 Concrete Paving for Airfields and Other Heavy Duty Pavements. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2017 | A | UFGS 32 13 14.13 Concrete Paving for Airfields and Other Heavy Duty Pavements | Nov-2017 | N | Superseding UFGS 32 13 11 Concrete Paving for Airfields and Other Heavy Duty Pavements. Complete review and update including section number and title changes. | |
| Aug-2017 | N | INACTIVE - UFGS 09 97 13.26 Coating of Steel Waterfront Structures, Zero VOC, (SZC) Splash Zone Coating | Feb-2016 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
| Aug-2017 | N | INACTIVE-UFGS 09 97 13.15 Low VOC Polysulfide Interior Coating of Welded Steel Petroleum Fuel Tanks | Feb-2015 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
| Aug-2017 | N | UFGS 01 14 00 Work Restrictions | Nov-2011 | C | 4 | Incorporation of DBIDS procedures for access to NAVY Installations. |
| Aug-2017 | N | UFGS 01 31 23.13 20 Electronic Construction and Facility Support Contract Management System (eCMS) | May-2017 | C | 1 | Changed submittal period of Personnel List, personnel roles, and removed Certified Payrolls, Invoice, and Routine Correspondence from Table 1; Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
| Aug-2017 | S | UFGS 01 33 00 Submittal Procedures | May-2011 | C | 10 | Updated to coordinate archiving of Navy Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a "Department-wide, Open Protocol, Energy Monitoring and Utility Control System Specification" for use in military construction and military family housing activities.: Changed MSDS to SDS |
| Aug-2017 | N | UFGS 01 33 29 Sustainability Requirements and Reporting | Feb-2017 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
| Aug-2017 | A | UFGS 01 42 00 Sources for Reference Publications | Nov-2014 | C | 2 | Updated address for the INTERNATION ORGANIZATION FOR STANDARDIZATION (ISO). |
| Aug-2017 | N | UFGS 01 45 00.00 20 Quality Control | Nov-2011 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
| Aug-2017 | N | UFGS 01 45 00.10 20 Quality Control for Minor Construction | Feb-2010 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
| Aug-2017 | A | UFGS 01 45 00.15 10 Resident Management System Contractor Mode (RMS CM) | Nov-2016 | C | 1 | Updated Resident Management System (RMS) requirements . |
| Aug-2017 | A | UFGS 01 91 00.15 Building Commissioning | May-2016 | C | 2 | Updated to coordinate archiving of Navy Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a "Department-wide, Open Protocol, Energy Monitoring and Utility Control System Specification" for use in Military construction and military family housing activity. |