This Unified Facilities Criteria (UFC) provides requirements for structures designed and constructed for the Department of Defense (DoD). These technical requirements are based on the 2024 International Building Code (2024 IBC), as modified by UFC 1-200-01, DoD Building Code, and the structural standard referenced by the 2024 IBC: ASCE/SEI 7-22 Minimum Design Loads and Associated Criteria for Buildings and Other Structures (hereinafter referred to simply as ASCE 7-22). The criteria further provides limited technical guidance for seismic evaluation and strengthening of existing buildings, and references ICSSC RP 10, Standards of Seismic Safety for Existing Federally Owned and Leased Buildings (RP 10) as well as ASCE/SEI 41-17, Seismic Evaluation and Retrofit of Existing Buildings (hereinafter referred to simply as ASCE 41-17). Additionally, for nonseismic retrofit of existing buildings, the criteria references the 2024 edition of the International Existing Building Code (2024 IEBC). This information is for use by structural engineers to develop deign calculations, specifications, plans, and design-build Requests for Proposal (RFPs), and it is meant to serve as the minimum deign requirement for DoD buildings.
Status
Active
View/Download
Publish Date
Change Date
Pages
238
Related Materials
Series
3 - DISCIPLINE-SPECIFIC CRITERIA
3-300: STRUCTURAL AND SEISMIC DESIGN
CCR
Summary
Superseded Versions
UFC 3-301-01 Structural Engineering, with Change 5 (01-14-2026)
UFC 3-301-01 Structural Engineering, with Change 4 (06-03-2025)
UFC 3-301-01 Structural Engineering, with Change 3 (02-03-2025)
UFC 3-301-01 Structural Engineering, with Change 2 (09-04-2024)
UFC 3-301-01 Structural Engineering, with Change 1 (10-02-2023)
UFC 3-301-01 Structural Engineering (04-11-2023)
UFC 3-301-01 Structural Engineering, with Change 1 (02-04-2022)
UFC 3-301-01 Structural Engineering (10-01-2019)
UFC 3-301-01 Structural Engineering, with Change 4 (11-01-2018)
UFC 3-301-01 Structural Engineering, with Change 3 (09-12-2016)
UFC 3-301-01 Structural Engineering, with Change 2 (06-20-2016)
UFC 3-301-01 Structural Engineering, with Change 1 (05-15-2014)
UFC 3-301-01 Structural Engineering (06-01-2013)
UFC 3-301-01 Structural Engineering, with Change 3 (01-31-2012)
UFC 3-301-01 Structural Engineering, with Change 2 (01-31-2011)
UFC 3-301-01 Structural Engineering, with Change 1 (07-20-2010)
UFC 3-301-01 Structural Engineering (01-27-2010)
UFC 3-310-07A Cold-Formed Load Bearing Steel Systems and Masonry Veneer/Steel Stud Walls (06-19-2006)
UFC 3-310-01 Structural Load Data, with Change 2 (12-05-2007)
UFC 3-310-01 Structural Load Data, with Change 1 (05-25-2005)
UFC 3-320-02A Design and Construction of Conventionally Reinforced Ribbed Mat Slabs (RRMS) (03-01-2005)
UFC 3-320-04A Metal Building Systems, with Change 2 (03-01-2005)
UFC 3-320-04A Metal Building Systems, with Change 1 (03-01-2005)
UFC 3-330-01A Commentary on Snow Loads (03-01-2005)