Unified Facilities Guide Specifications (UFGS)  Subscribe to Unified Facilities Guide Specifications (UFGS)

UFGS Master Updated August 13, 2020; Posted August 20, 2020

Unified Facilities Guide Specifications (UFGS) are a joint effort of the U.S. Army Corps of Engineers (USACE), the Naval Facilities Engineering Command (NAVFAC), the Air Force Civil Engineer Center (HQ AFCEC) and the National Aeronautics and Space Administration (NASA). UFGS are for use in specifying construction for the military services.

The Unified Facilities Guide Specifications (UFGS) are published only in electronic format and are intended to be used with SpecsIntact software. The UFGS Master uses the latest CSI MasterFormat, therefore, as of January 2012, the UFGS Working Group decided to discontinue support of MasterFormat 1995. SpecsIntact version 4.5.1 and above will support MasterFormat 2010 and will no longer support the creation of Jobs or Masters using the old MasterFormat 1995 UFGS Master. For backward compatibility, Masters or Jobs created with older versions can still be opened using the latest software versions.

As of June 2008 :Updated UFGS will be posted quarterly in February, May, August and November.

As of May 2013: The May 2013 release incorporates Automatic Paragraph Numbering. Versions of Specsintact older than 4.5.0 are not compatible with this feature. Existing jobs can be converted to the new automatic numbered format. The conversion is a one-way process. To convert, select the job or master, select process menu, choose convert Job/Master to Automatic numbering. More information about Automatic Paragraph Numbering is available on the SpecsIntact website.

For Specsintact Technical Support: 321-867-8800  |   E-mail  |   specsintact.ksc.nasa.gov

UFGS that have been unified for use by all participating agencies have a level 3 or level 4 MasterFormat™ number. UFGS that are agency-specific have a fifth level number indicating it as an agency specific specification. A specification that has a fifth level number "10" indicates USACE, a "20" indicates NAVFAC, a "30" indicates AFCEC, and a "40" indicates NASA. Preparing agencies are indicated in the UFGS header of each specification. The user should follow this order of precedence in selecting UFGS sections:

  1. Regional UFGS specific to their Agency
  2. UFGS identified as specific to their Agency
  3. Unified UFGS if one is available
  4. UFGS identified as specific to another DoD Agency (for DoD projects only)
  5. UFGS from another agency.

Points of contact and procedures for the development and maintenance of UFGS documents are prescribed in the latest edition of MIL-STD-3007.

Section templates for MasterFormat 2010 and MasterFormat 1995: These templates are provided to assist the user in creating a new section.

SpecsIntact for NMCI Users

Questions, comments, suggestions and recommended changes for guide specifications are welcome and should be submitted as a Criteria Change Request. To submit a Criteria Change Request, click on the CCR link next to the document below. If a CCR does not fit cleanly into an existing section, submit a CCR to the section most closely related to the CCR. CCRs are not appropriate when they pertain to a specific project solicitation, request for proposal or after a project award. Questions or interpretations pertaining to these documents or situation should be referred to the Contracting Officer.

Click the 'Title' or 'Date' heading to sort by ascending or descending order. Narrow the list by selecting a 'Division' option from the drop-down or view archived documents by selecting from the 'Status' drop-down and clicking 'Apply'.

These documents are available in the following formats:   Adobe Acrobat (PDF)  |   SpecsIntact (SEC) in compressed ZIP

  Indicates the UFGS has an attachment. Click the title to view the attachment under 'Related Materials'.

Titlesort ascending Date View CCR
UFGS 07 51 13 Built-Up Asphalt Roofing   05-01-2012  PDF |  ZIP  CCR
UFGS 07 42 63 Fabricated Wall Panel Assemblies   05-01-2011  PDF |  ZIP  CCR
UFGS 07 42 13 Metal Wall Panels   05-01-2011  PDF |  ZIP  CCR
UFGS 07 41 63 Fabricated Roof Panel Assemblies   11-01-2016  PDF |  ZIP  CCR
UFGS 07 41 13.16 Copper Roof Panels   08-01-2009  PDF |  ZIP  CCR
UFGS 07 41 13 Metal Roof Panels   05-01-2011  PDF |  ZIP  CCR
UFGS 07 32 14 Clay Tile Roofing Replacement or Repair   04-01-2006  PDF |  ZIP  CCR
UFGS 07 32 13 Roof Tiles   04-01-2006  PDF |  ZIP  CCR
UFGS 07 31 26 Slate Shingles   08-01-2009  PDF |  ZIP  CCR
UFGS 07 31 13 Asphalt Shingles   08-01-2016  PDF |  ZIP  CCR
UFGS 07 27 36 Spray Foam Air Barriers   05-01-2017  PDF |  ZIP  CCR
UFGS 07 27 26 Fluid-Applied Membrane Barriers   05-01-2017  PDF |  ZIP  CCR
UFGS 07 27 19.01 Self-Adhering Air Barriers   05-01-2017  PDF |  ZIP  CCR
UFGS 07 27 10.00 10 Building Air Barrier System   08-01-2019  PDF |  ZIP  CCR
UFGS 07 24 00 Exterior Insulation and Finish Systems   05-01-2011  PDF |  ZIP  CCR
UFGS 07 22 00 Roof and Deck Insulation   02-01-2016  PDF |  ZIP  CCR
UFGS 07 21 23 Loose Fill Thermal Insulation   05-01-2011  PDF |  ZIP  CCR
UFGS 07 21 16 Mineral Fiber Blanket Insulation   11-01-2011  PDF |  ZIP  CCR
UFGS 07 21 13 Board and Block Insulation   02-01-2016  PDF |  ZIP  CCR
UFGS 07 19 00 Water Repellents   05-01-2011  PDF |  ZIP  CCR
UFGS 07 17 00 Bentonite Waterproofing   02-01-2016  PDF |  ZIP  CCR
UFGS 07 16 19 Metallic Oxide Waterproofing   01-01-2007  PDF |  ZIP  CCR
UFGS 07 14 00 Fluid-Applied Waterproofing   02-01-2012  PDF |  ZIP  CCR
UFGS 07 13 53 Elastomeric Sheet Waterproofing   02-01-2016  PDF |  ZIP  CCR
UFGS 07 12 00 Built-Up Bituminous Waterproofing   02-01-2016  PDF |  ZIP  CCR
UFGS 07 11 13 Bituminous Dampproofing   08-01-2011  PDF |  ZIP  CCR
UFGS 07 05 23 Pressure Testing an Air Barrier System for Air Tightness   08-01-2019  PDF |  ZIP  CCR
UFGS 06 82 14 Fiberglass Reinforced Plastic (FRP) Pipe and Tube Railings   05-01-2018  PDF |  ZIP  CCR
UFGS 06 73 01 Fiberglass Reinforced Plastic (FRP) Grating   05-01-2018  PDF |  ZIP  CCR
UFGS 06 71 33 Fiberglass Reinforced Plastic (FRP) Ladders   05-01-2018  PDF |  ZIP  CCR
UFGS 06 61 16 Solid Surfacing Fabrications   08-01-2020  PDF |  ZIP  CCR
UFGS 06 41 16.00 10 Plastic-Laminate-Clad Architectural Cabinets   08-01-2010  PDF |  ZIP  CCR
UFGS 06 20 00 Finish Carpentry   08-01-2016  PDF |  ZIP  CCR
UFGS 06 18 00 Glue-Laminated Construction   08-01-2016  PDF |  ZIP  CCR
UFGS 06 17 19 Cross-Laminated Timber   11-01-2016  PDF |  ZIP  CCR
UFGS 06 13 33 Pier Timberwork   11-01-2016  PDF |  ZIP  CCR
UFGS 06 10 00 Rough Carpentry   08-01-2016  PDF |  ZIP  CCR
UFGS 05 72 00 Decorative Metal Specialties   05-01-2018  PDF |  ZIP  CCR
UFGS 05 59 20 Fabrication Of Hydraulic Steel Structures   08-01-2018  PDF |  ZIP  CCR
UFGS 05 59 10 Rolling Cover for Aviation Refueling Vaults   08-01-2018  PDF |  ZIP  CCR
UFGS 05 52 00 Metal Railings   02-01-2018  PDF |  ZIP  CCR
UFGS 05 51 33 Metal Ladders   02-01-2016  PDF |  ZIP  CCR
UFGS 05 51 00 Metal Stairs   02-01-2017  PDF |  ZIP  CCR
UFGS 05 50 15 Civil Works Fabrications   08-01-2018  PDF |  ZIP  CCR
UFGS 05 50 14 Structural Metal Fabrications   08-01-2018  PDF |  ZIP  CCR
UFGS 05 50 13 Miscellaneous Metal Fabrications   05-01-2017  PDF |  ZIP  CCR
UFGS 05 40 00 Cold-Formed Metal Framing   05-01-2015  PDF |  ZIP  CCR
UFGS 05 30 00 Steel Decks   05-01-2015  PDF |  ZIP  CCR
UFGS 05 21 00 Steel Joist Framing   05-01-2015  PDF |  ZIP  CCR
UFGS 05 14 00.13 Welding Structural Aluminum Framing   11-01-2019  PDF |  ZIP  CCR
UFGS 05 12 00 Structural Steel   08-01-2018  PDF |  ZIP  CCR
UFGS 05 05 23.16 Structural Welding   08-01-2018  PDF |  ZIP  CCR
UFGS 05 05 23.13 10 Ultrasonic Inspection of Weldments   08-01-2018  PDF |  ZIP  CCR
UFGS 04 23 00 Glass Unit Masonry   11-01-2015  PDF |  ZIP  CCR
UFGS 04 20 00 Unit Masonry   11-01-2015  PDF |  ZIP  CCR
UFGS 04 03 00 Conservation Treatment for Period Masonry   11-01-2017  PDF |  ZIP  CCR
UFGS 04 01 20.75 Masonry Strengthening Using Surface Applied FRP Composites   11-01-2015  PDF |  ZIP  CCR
UFGS 04 01 20.73 Masonry Strengthening Using FRP Bars   11-01-2015  PDF |  ZIP  CCR
UFGS 03 70 00 Mass Concrete   02-01-2010  PDF |  ZIP  CCR
UFGS 03 62 16 Metallic Non-Shrink Grouting   02-01-2018  PDF |  ZIP  CCR
UFGS 03 53 14.00 20 Light Reflective Nonferrous Metallic Aggregate Floor System   02-01-2010  PDF |  ZIP  CCR
UFGS 03 52 16.19 Lightweight Insulation Concrete Overlay   08-01-2011  PDF |  ZIP  CCR
UFGS 03 52 16 Lightweight Insulation Concrete   04-01-2008  PDF |  ZIP  CCR
UFGS 03 52 00 Lightweight Concrete Roof Insulation   08-01-2011  PDF |  ZIP  CCR
UFGS 03 51 13 Cementitious Wood Fiber Decks   05-01-2016  PDF |  ZIP  CCR
UFGS 03 47 13 Tilt-Up Concrete   08-01-2016  PDF |  ZIP  CCR
UFGS 03 45 33 Precast [Prestressed] Structural Concrete   05-01-2016  PDF |  ZIP  CCR
UFGS 03 45 00 Precast Architectural Concrete   05-01-2016  PDF |  ZIP  CCR
UFGS 03 44 00 Reinforced Autoclave Aerated Concrete Panels   02-01-2013  PDF |  ZIP  CCR
UFGS 03 42 13.00 10 Plant-Precast Concrete Products for Below Grade Construction   05-01-2016  PDF |  ZIP  CCR
UFGS 03 41 33 Precast Structural Pretensioned Concrete   11-01-2016  PDF |  ZIP  CCR
UFGS 03 41 16.08 Precast Concrete Slabs (MAX. SPAN 8 FEET O.C.)   11-01-2019  PDF |  ZIP  CCR
UFGS 03 37 29 Concrete for Concrete Cutoff Walls   11-01-2009  PDF |  ZIP  CCR
UFGS 03 37 23 Roller-Compacted Concrete for Mass Concrete Construction   11-01-2009  PDF |  ZIP  CCR
UFGS 03 37 13 Shotcrete   02-01-2018  PDF |  ZIP  CCR
UFGS 03 37 00 Preplaced-Aggregate Concrete   11-01-2009  PDF |  ZIP  CCR
UFGS 03 33 00 Cast-In-Place Architectural Concrete   11-01-2009  PDF |  ZIP  CCR
UFGS 03 31 30 Marine Concrete   02-01-2019  PDF |  ZIP  CCR
UFGS 03 31 29 Marine Concrete with Service Life Modeling   02-01-2019  PDF |  ZIP  CCR
UFGS 03 30 53 Miscellaneous Cast-In-Place Concrete   05-01-2014  PDF |  ZIP  CCR
UFGS 03 30 00 Cast-In-Place Concrete   02-01-2019  PDF |  ZIP  CCR
UFGS 03 23 00 Stressed Tendon Reinforcing   05-01-2016  PDF |  ZIP  CCR
UFGS 03 01 00 Rehabilitation of Concrete   02-01-2018  PDF |  ZIP  CCR
UFGS 02 85 00 Mold Remediation   11-01-2018  PDF |  ZIP  CCR
UFGS 02 84 33 Removal and Disposal of Polychlorinated Biphenyls (PCBs)   05-01-2020  PDF |  ZIP  CCR
UFGS 02 84 16 Handling of Lighting Ballasts and Lamps Containing PCBs and Mercury   05-01-2020  PDF |  ZIP  CCR
UFGS 02 83 00 Lead Remediation   11-01-2018  PDF |  ZIP  CCR
UFGS 02 82 00 Asbestos Remediation   11-01-2018  PDF |  ZIP  CCR
UFGS 02 81 00 Transportation and Disposal of Hazardous Materials   11-01-2018  PDF |  ZIP  CCR
UFGS 02 66 10 Test Fill   02-01-2010  PDF |  ZIP  CCR
UFGS 02 66 00 Select Fill and Topsoil for Landfill Cover   02-01-2010  PDF |  ZIP  CCR
UFGS 02 65 00 Underground Storage Tank Removal   02-01-2010  PDF |  ZIP  CCR
UFGS 02 62 16.16 10 Commissioning and Demonstration for Soil Vapor Extraction (SVE) Systems   08-01-2018  PDF |  ZIP  CCR
UFGS 02 62 16.13 10 Operation, Maintenance and Process Monitoring for Soil Vapor Extraction (SVE) Systems   08-01-2018  PDF |  ZIP  CCR
UFGS 02 62 13.00 10 Air and Steam Stripping   08-01-2018  PDF |  ZIP  CCR
UFGS 02 61 23 Removal and Disposal of PCB Contaminated Soils   04-01-2006  PDF |  ZIP  CCR
UFGS 02 61 13 Excavation and Handling of Contaminated Material   02-01-2010  PDF |  ZIP  CCR
UFGS 02 56 15 Geosynthetic Clay Liner (GCL)   02-01-2010  PDF |  ZIP  CCR
UFGS 02 56 14 Clay Barrier Layer   02-01-2010  PDF |  ZIP  CCR
UFGS 02 56 13 Waste Containment Geomembrane   02-01-2010  PDF |  ZIP  CCR
UFGS 02 55 00 Solidification/Stabilization (S/S) of Contaminated Material   02-01-2010  PDF |  ZIP  CCR
UFGS 02 54 23 Soil Washing Through Separation/Solubilization   02-01-2010  PDF |  ZIP  CCR
UFGS 02 54 21 Bioremediation of Soils Using Windrow Composting   02-01-2010  PDF |  ZIP  CCR
UFGS 02 54 20 Bioremediation of Soils Using Landfarming Systems   02-01-2010  PDF |  ZIP  CCR
UFGS 02 53 16 Remediation of Contaminated Soils By Thermal Desorption   02-01-2010  PDF |  ZIP  CCR
UFGS 02 51 13 Precipitation/Coagulation/Flocculation Water Treatment   05-01-2010  PDF |  ZIP  CCR
UFGS 02 42 91 Removal and Salvage of Historic Construction Materials   11-01-2018  PDF |  ZIP  CCR
UFGS 02 42 51 Carpet Removal and Reclamation   11-01-2019  PDF |  ZIP  CCR
UFGS 02 41 00 [Demolition] [and] [Deconstruction]   05-01-2010  PDF |  ZIP  CCR
UFGS 02 35 27 Soil-Bentonite (S-B) Slurry Trench   05-01-2010  PDF |  ZIP  CCR
UFGS 02 32 00 Subsurface Drilling, Sampling, and Testing   05-01-2010  PDF |  ZIP  CCR
UFGS 01 91 00.15 Total Building Commissioning   02-01-2019  PDF |  ZIP  CCR
UFGS 01 91 00.15 10 Total Building Commissioning   05-01-2019  PDF |  ZIP  CCR
UFGS 01 86 26.07 40 Reliability Centered Acceptance for Electrical Systems   02-01-2018  PDF |  ZIP  CCR
UFGS 01 86 12.07 40 Reliability Centered Acceptance for Mechanical Systems   02-01-2018  PDF |  ZIP  CCR
UFGS 01 83 13.07 40 Reliability Centered Acceptance for Superstructure Performance Requirements   02-01-2018  PDF |  ZIP  CCR
UFGS 01 83 00.07 40 Reliability Centered Acceptance for Facility Shells   02-01-2018  PDF |  ZIP  CCR
UFGS 01 78 24.00 20 Facility Electronic Operation and Maintenance Support Information (eOMSI)   02-01-2015  PDF |  ZIP  CCR
UFGS 01 78 24.00 10 Facility Data Requirements   05-01-2018  PDF |  ZIP  CCR
UFGS 01 78 23.33 Operation and Maintenance Manuals for Aviation Fuel Systems   08-01-2018  PDF |  ZIP  CCR
UFGS 01 78 23 Operation and Maintenance Data   08-01-2015  PDF |  ZIP  CCR
UFGS 01 78 00 Closeout Submittals   05-01-2019  PDF |  ZIP  CCR
UFGS 01 74 19 Construction Waste Management and Disposal   02-01-2019  PDF |  ZIP  CCR
UFGS 01 58 00 Project Identification   08-01-2019  PDF |  ZIP  CCR
UFGS 01 57 19.01 20 Supplemental Temporary Environmental Controls   11-01-2015  PDF |  ZIP  CCR