KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA |
---|---|---|---|---|---|
ACTION | N New | R Revision | C Change | D Deletion |
Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
---|---|---|---|---|---|---|
Jun-2006 | S | UFGS 05 30 00.00 40 Steel Decks | Jun-2006 | R | At Subpart 3.2.6 w/note, Replaced Section number 03 40 00.00 40 with 03 30 00.00 40; Updated References | |
May-2010 | N | UFGS 05 40 00 Cold-Formed Metal Framing | May-2010 | R | Removed para 3.2.5 and notes in 3.1.1, 3.1.2, 3.1.3; added para 3.1.4; other minor revisions throughout | |
Aug-2012 | N | UFGS 05 40 00 Cold-Formed Metal Framing | May-2010 | C | 1 | Modified subparts 1.2 (SD-07), 1.3, 1.6, 2.1, 2.1.1, 2.1.2, 3.2; removed 2.4 "Paint" |
May-2015 | N | UFGS 05 40 00 Cold-Formed Metal Framing | May-2015 | R | Major revisions to comply with IBC 2012 | |
Aug-2018 | N | UFGS 05 40 00 Cold-Formed Metal Framing | May-2015 | C | 1 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Aug-2008 | N | UFGS 05 50 00 Metal: Miscellaneous and Fabrications | Apr-2006 | D | Superseded by UFGS 05 50 13 Miscellaneous Metal Fabrications, UFGS 05 51 33 Metal Ladders, UFGS 05 52 00 Metal Railings, and UFGS 05 51 00 Metal Stairs Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 05 50 00.00 40 Metal Fabrications | Oct-2006 | D | Information already provided in UFGS Sections 05 50 00 Metal Fabrications, 05 50 03.00 10 Metalwork Fabrication, Machine Work, Miscellaneous Provisions, and 05 50 04.00 10 Metals: Miscellaneous, Standard Article, Shop Fabricated Items for Civil Works Structures. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2006 | S | UFGS 05 50 00.00 40 Metal Fabrications | Oct-2006 | R | Section References (SRF) update | |
Jun-2006 | S | UFGS 05 50 00.00 40 Metal Fabrications | Jun-2006 | R | Section References (SRF) updated | |
Aug-2008 | A | UFGS 05 50 03.00 10 Metalwork Fabrication, Machine Work, Miscellaneous Provisions | Apr-2006 | D | Superseded by UFGS 05 50 14 Structural Metal Fabrications Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2006 | A | UFGS 05 50 04 Metals: Miscellaneous, Standard Articles, Shop Fabricated Items for Civil Works Structures | Jan-2004 | D | Superseded by UFGS 05 50 04.00 10 Metals: Miscellaneous, Standard Articles, Shop Fabricated Items for Civil Works Structures Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2008 | A | UFGS 05 50 04.00 10 Metals: Miscellaneous, Standard Articles, Shop Fabricated Items for Civil Works Structures | Jul-2006 | D | Superseded by UFGS 05 50 15 Civil Works Fabrications Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2006 | A | UFGS 05 50 04.00 10 Metals: Miscellaneous, Standard Articles, Shop Fabricated Items for Civil Works Structures | Jul-2006 | N | New - Superseding UFGS 05 50 04 Metals: Miscellaneous, Standard Articles, Shop Fabricated Items for Civil Works Structures | |
May-2017 | N | UFGS 05 50 13 Miscellaneous Metal Fabrications | May-2017 | R | Addressed the following CCRs: 1669-Include welded headed shear studs; 3556-Access Doors and panels relocated to new UFGS 08 31 00 ACCESS DOORS AND PANELS; Added different types of downspout terminations | |
May-2010 | N | UFGS 05 50 13 Miscellaneous Metal Fabrications | May-2010 | R | Revised note #4 before part 1, para 2.1.7.5 and 2.1.7.6; other minor revisions throughout | |
Aug-2008 | N | UFGS 05 50 13 Miscellaneous Metal Fabrications | Aug-2008 | N | Superseding UFGS 05 50 00 Metal: Miscellaneous and Fabrications. Note: information on LADDERS removed - See UFGS 05 51 33 Metal Ladders; information on STAIRS removed- See UFGS 05 51 00 Metal Stairs; information on HANDRAILS removed - See UFGS 05 52 00 Metal Railings | |
Aug-2018 | N | UFGS 05 50 13 Miscellaneous Metal Fabrications | May-2017 | C | 1 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
May-2014 | A | UFGS 05 50 14 Structural Metal Fabrications | May-2014 | R | Major revision to comply with ICC IBC 2012 | |
Aug-2008 | A | UFGS 05 50 14 Structural Metal Fabrications | Aug-2008 | N | Superseding UFGS 05 50 03.00 10 Metalwork Fabrication, Machine Work, Miscellaneous Provisions | |
Nov-2008 | A | UFGS 05 50 14 Structural Metal Fabrications | Nov-2008 | R | Updated references to specific paragraphs in AWS D1.1 | |
Aug-2018 | A | UFGS 05 50 14 Structural Metal Fabrications | Aug-2018 | R | Complete review and update. | |
May-2014 | A | UFGS 05 50 15 Civil Works Fabrications | May-2014 | R | Major revision to comply with ICC IBC 2012 | |
Aug-2008 | A | UFGS 05 50 15 Civil Works Fabrications | Aug-2008 | N | Superseding UFGS 05 50 04.00 10 Metals: Miscellaneous, Standard Articles, Shop Fabricated Items for Civil Works Structures | |
Aug-2018 | A | UFGS 05 50 15 Civil Works Fabrications | Aug-2018 | R | Complete review and update. | |
May-2017 | S | UFGS 05 51 00 Metal Stairs | Feb-2017 | C | 1 | Incorporated CCR 5531, revised paragraphs 2.4.1, and 2.4.2 |
Feb-2017 | S | UFGS 05 51 00 Metal Stairs | Feb-2017 | R | Tri-Annual Database Maintenance (TADM) completed | |
May-2009 | S | UFGS 05 51 00 Metal Stairs | May-2009 | R | General update | |
Apr-2008 | S | UFGS 05 51 00 Metal Stairs | Apr-2008 | N | Superseding UFGS 05 51 00.00 40 Metal Stairs | |
May-2014 | S | UFGS 05 51 00 Metal Stairs | Feb-2012 | C | 1 | SRF update, changed 05 05 23 WELDING, STRUCTURAL to 05 05 23.16 STRUCTURAL WELDING. |
Feb-2012 | S | UFGS 05 51 00 Metal Stairs | Feb-2012 | R | Tri-Annual Database Maintenance - Subpart 1.2 Submittal Article Compliance | |
Aug-2023 | S | UFGS 05 51 00 Metal Stairs | Aug-2023 | R | Complete life cycle review. Update technical requirements, references, formatting. Incorporated CCR# 5458, 7328, 11237 | |
Nov-2023 | N | UFGS 05 51 00 Metal Stairs | Aug-2023 | C | Administrative Change: Preparing Activity changed from NASA to NAVFAC. | |
Apr-2008 | S | UFGS 05 51 00.00 40 Metal Stairs | Jul-2007 | D | Superseded; Renumbered as UFGS 05 51 00 with no title change Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | S | UFGS 05 51 00.00 40 Metal Stairs | Jul-2007 | R | Reference and Section References (SRF) update | |
Apr-2007 | S | UFGS 05 51 00.00 40 Metal Stairs | Apr-2007 | R | Reference Update | |
Jan-2007 | S | UFGS 05 51 00.00 40 Metal Stairs | Jan-2007 | R | Section References (SRF) update | |
Jun-2006 | S | UFGS 05 51 00.00 40 Metal Stairs | Jun-2006 | R | Section References (SRF) updated | |
Aug-2017 | N | UFGS 05 51 33 Metal Ladders | Feb-2016 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Feb-2016 | N | UFGS 05 51 33 Metal Ladders | Feb-2016 | R | Revised to incorporate the addition of ladder safety device requirement and editorial changes. | |
Feb-2018 | N | UFGS 05 51 33 Metal Ladders | Feb-2016 | C | 2 | Incorporated the changes from the final rule 29 CFR 1910 (Nov 2016) affecting phasing out cages installed on fixed ladders |
May-2010 | N | UFGS 05 51 33 Metal Ladders | May-2010 | R | Revised para 3.3; other minor revisions throughout | |
Aug-2008 | N | UFGS 05 51 33 Metal Ladders | Aug-2008 | N | Superseding LADDER portion of UFGS 05 50 00 Metal: Miscellaneous and Fabrications | |
Feb-2018 | S | UFGS 05 52 00 Metal Railings | Feb-2018 | R | Tri-Annual Database Maintenance (TADM) completed | |
Aug-2015 | S | UFGS 05 52 00 Metal Railings | Aug-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
Apr-2008 | S | UFGS 05 52 00 Metal Railings | Apr-2008 | N | Due to Disassembly | |
May-2014 | S | UFGS 05 52 00 Metal Railings | Feb-2011 | C | 3 | SRF update, changed 05 05 23 WELDING, STRUCTURAL to STRUCTURAL WELDING |
Nov-2012 | S | UFGS 05 52 00 Metal Railings | Feb-2011 | C | 2 | Imperative language |
Aug-2012 | S | UFGS 05 52 00 Metal Railings | Feb-2011 | C | 1 | Updated Imperative Language; no technical content changes have been made |
Feb-2011 | S | UFGS 05 52 00 Metal Railings | Feb-2011 | R | Revised General Note, added subpart 1.2, 2.2, 3.1; submittal article compliance; deleted subpart 2.1.2; other minor revisions throughout. | |
Aug-2023 | S | UFGS 05 52 00 Metal Railings | Aug-2023 | R | Complete life cycle review. Update technical requirements, references, formatting. Incorporated CCR# 11143 | |
Nov-2023 | N | UFGS 05 52 00 Metal Railings | Aug-2023 | C | Administrative Change: Preparing Activity changed from NASA to NAVFAC. | |
Feb-2010 | A | UFGS 05 59 10 Rolling Cover for Aviation Refueling Vaults | Feb-2010 | N | New section | |
Aug-2018 | A | UFGS 05 59 10 Rolling Cover for Aviation Refueling Vaults | Aug-2018 | R | Complete review and update. | |
Nov-2022 | A | UFGS 05 59 10 Rolling Cover for Aviation Refueling Vaults | Nov-2022 | R | Complete review and update | |
Aug-2009 | A | UFGS 05 59 13 Fabrication of Hydraulic Steel Structures | Aug-2009 | N | New section | |
May-2018 | A | UFGS 05 59 13 Fabrication of Hydraulic Steel Structures | Aug-2009 | C | 1 | Changes were made in order to ensure proper reference to updated ASTM Standards including ASTM A709 and ASTM F3125. Additionally the new AISC HYD certification for the fabrication of Hydraulic Steel Structures was added. |
Aug-2018 | A | UFGS 05 59 13 Fabrication of Hydraulic Steel Structures | Aug-2009 | D | Superseded by UFGS 05 59 20 FABRICATION OF HYDRAULIC STEEL STRUCTURES. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | A | UFGS 05 59 20 Fabrication Of Hydraulic Steel Structures | Aug-2018 | N | Superseding UFGS 05 59 13 FABRICATION OF HYDRAULIC STEEL STRUCTURES. Complete review and update including section number change. | |
May-2021 | A | UFGS 05 59 20 Fabrication Of Hydraulic Steel Structures | May-2021 | R | Complete review and update. | |
Jul-2007 | S | UFGS 05 70 00.00 40 Decorative Metals | Apr-2007 | D | Superseded by UFGS 05 72 00 Decorative Metal Specialties Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | S | UFGS 05 70 00.00 40 Decorative Metals | Apr-2007 | R | Reference Update | |
Jun-2006 | S | UFGS 05 70 00.00 40 Decorative Metals | Jun-2006 | R | Title changed from ORNAMENTAL METAL; Section References (SRF) updated | |
May-2011 | S | UFGS 05 72 00 Decorative Metal Specialties | May-2011 | R | CCR 496: Minor revisions | |
Feb-2015 | S | UFGS 05 72 00 Decorative Metal Specialties | Feb-2012 | C | 1 | Consist of imperative language, spell check, QC reports, and formatting review . |
May-2009 | S | UFGS 05 72 00 Decorative Metal Specialties | May-2009 | R | General update | |
May-2018 | S | UFGS 05 72 00 Decorative Metal Specialties | May-2018 | R | Tri-Annual Database Maintenance (TADM) completed | |
Feb-2012 | S | UFGS 05 72 00 Decorative Metal Specialties | Feb-2012 | R | Tri-Annual Database Maintenance - Subpart 1.2 Submittal Article Compliance; minor revisions 3.3 | |
Jul-2007 | S | UFGS 05 72 00 Decorative Metal Specialties | Jul-2007 | N | Superseding UFGS 05 70 00.00 40 Decorative Metals, Reference Update | |
Aug-2023 | S | UFGS 05 72 00 Decorative Metal Specialties | Aug-2023 | R | Complete life cycle review. Update technical requirements, references, formatting. | |
Nov-2023 | N | UFGS 05 72 00 Decorative Metal Specialties | Aug-2023 | C | Administrative Change: Preparing Activity changed from NASA to NAVFAC. | |
Aug-2016 | N | UFGS 06 10 00 Rough Carpentry | Aug-2016 | R | Alignment with Federal and DoD sustainability requirements for tracking and reporting | |
May-2011 | N | UFGS 06 10 00 Rough Carpentry | May-2011 | R | Reference updates: modified subparts 2.5.10.2 and 3.5; Removed subparts 2.6.5 and 2.6.9 | |
Nov-2009 | N | UFGS 06 10 00 Rough Carpentry | Nov-2009 | R | Modified AWPA publication reference designations and other minor changes | |
Nov-2008 | N | UFGS 06 10 00 Rough Carpentry | Nov-2008 | R | Reference/organization name change from APA to AWPA | |
Feb-2012 | N | UFGS 06 10 00 Rough Carpentry | Feb-2012 | R | Modified subparts 1.8, 2.6 and 2.6.6 | |
Aug-2018 | N | UFGS 06 10 00 Rough Carpentry | Aug-2016 | C | 1 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Jul-2006 | N | UFGS 06 10 00 Rough Carpentry | Jul-2006 | R | Added sustainable design requirements | |
Nov-2018 | N | UFGS 06 10 00 Rough Carpentry | Aug-2016 | C | 2 | Added notes for requirement of preservative treatment and hot-dip galvanized rough hardware in ESC C3 thru C5 and humid locations, and not to use particle board or OSB in C4 and C5 and humid locations. |
Aug-2017 | N | UFGS 06 13 33 Pier Timberwork | Nov-2016 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2013 | N | UFGS 06 13 33 Pier Timberwork | Apr-2006 | C | 1 | Modified subpart 2.1.1.2 |
Nov-2016 | N | UFGS 06 13 33 Pier Timberwork | Nov-2016 | R | Revised to address changes in preservative treatments for Pier Timberwork. | |
Nov-2016 | A | UFGS 06 17 19 Cross-Laminated Timber | Nov-2016 | N | New Section | |
Nov-2018 | A | UFGS 06 17 19 Cross-Laminated Timber | Nov-2016 | C | 1 | Added recommendation not to use CLT in humid or ESC locations C4 and C5. |
May-2021 | A | UFGS 06 17 19 Cross-Laminated Timber | Nov-2016 | C | 2 | Deleted 2nd note paragraph in subpart 2.2.3 in response to CCR 8979. |
Aug-2016 | S | UFGS 06 18 00 Glued-Laminated Construction | Aug-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
May-2009 | S | UFGS 06 18 00 Glued-Laminated Construction | May-2009 | R | General update | |
Nov-2013 | S | UFGS 06 18 00 Glued-Laminated Construction | Nov-2013 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2008 | S | UFGS 06 18 00 Glued-Laminated Construction | Nov-2008 | R | Organization name change | |
Jul-2007 | S | UFGS 06 18 00 Glued-Laminated Construction | Jul-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 06 18 00 Glued-Laminated Construction | Apr-2007 | R | Titled changed from GLUE-LAMINATED STRUCTURAL UNITS; Reference Update | |
Jun-2006 | S | UFGS 06 18 00 Glued-Laminated Construction | Jun-2006 | N | New - Superseding UFGS 06 18 00.00 40 Glue-Laminated Structural Units | |
Nov-2018 | S | UFGS 06 18 00 Glued-Laminated Construction | Aug-2016 | C | 1 | Added Note to not use GLC in ESC C4 and C5 and humid locations. |
Aug-2023 | S | UFGS 06 18 00 Glued-Laminated Construction | Aug-2023 | R | Complete life cycle review. Update technical requirements, references, formatting. | |
Nov-2023 | A | UFGS 06 18 00 Glued-Laminated Construction | Aug-2023 | C | Administrative Change: Preparing Activity changed from NASA to USACE. | |
Jun-2006 | S | UFGS 06 18 00.00 40 Glue-Laminated Construction | Apr-2006 | D | Superseded by UFGS 06 18 00 Glue-Laminated Structural Units Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2016 | N | UFGS 06 20 00 Finish Carpentry | Aug-2016 | R | Alignment with Federal and DoD sustainability requirements for tracking and reporting | |
Feb-2016 | N | UFGS 06 20 00 Finish Carpentry | Feb-2016 | R | Complete revision; revised throughout to incorporate ccrs 2803, 1484,and 2424; update format and editorial changes. | |
Aug-2008 | N | UFGS 06 20 00 Finish Carpentry | Aug-2008 | R | Updated para 2.10.3.1 | |
Feb-2012 | N | UFGS 06 20 00 Finish Carpentry | Feb-2012 | R | Modified subpart 2.5.2 | |
Aug-2018 | N | UFGS 06 20 00 Finish Carpentry | Aug-2016 | C | 1 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |