KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA |
---|---|---|---|---|---|
ACTION | N New | R Revision | C Change | D Deletion |
Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
---|---|---|---|---|---|---|
Aug-2015 | A | UFGS 07 62 10 Copper Sheet Metal Flashing | Aug-2009 | D | Superseded by UFGS 07 62 13 Copper Sheet Metal Flashing and Trim; Nontechnical number and title change Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2009 | A | UFGS 07 62 10 Copper Sheet Metal Flashing | Aug-2009 | R | Compliance with CSI SectionFormat | |
Aug-2016 | N | UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing | Aug-2016 | R | Alignment with Federal and DoD sustainability requirements for tracking and reporting | |
Jan-2008 | N | UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing | Apr-2006 | D | Superseded by UFGS 07 41 13 Metal Roof Panels Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2008 | N | UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing | Aug-2008 | N | Reinstated for NAVFAC use | |
May-2011 | N | UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing | May-2011 | R | Reference updates: modified subparts 1.3.2.1 (notes) and 2.5.3 | |
Aug-2018 | N | UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing | Aug-2016 | C | 1 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Nov-2018 | N | UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing | Aug-2016 | C | 2 | Added note for use of coated alclad in ESC C3-C5 locations. |
Aug-2016 | N | UFGS 07 61 14.00 20 Steel Standing Seam Roofing | Aug-2016 | R | Alignment with Federal and DoD sustainability requirements for tracking and reporting | |
Jan-2008 | N | UFGS 07 61 14.00 20 Steel Standing Seam Roofing | Apr-2006 | D | Superseded by UFGS 07 41 13 Metal Roof Panels Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2008 | N | UFGS 07 61 14.00 20 Steel Standing Seam Roofing | Aug-2008 | N | Reinstated for NAVFAC use | |
May-2011 | N | UFGS 07 61 14.00 20 Steel Standing Seam Roofing | May-2011 | R | Reference updates: modified notes in subparts 1.3.2.1, 1.3.2.2, 1.3.2.3, 1.6.6; Modified subparts 1.6.6 and 2.3 | |
Aug-2018 | N | UFGS 07 61 14.00 20 Steel Standing Seam Roofing | Aug-2016 | C | 1 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Jan-2008 | A | UFGS 07 61 13.00 10 Structural Steel Standing Seam Metal Roof (SSSMR) System | Apr-2006 | D | Superseded by UFGS 07 41 13 Metal Roof Panels and UFGS 07 41 63 Fabricated Roof Panel Assemblies Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2015 | A | UFGS 07 61 01 Copper Roof System | Aug-2009 | D | Superseded by UFGS 07 41 13.16 Copper Roof Panels; Nontechnical number and title change Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2009 | A | UFGS 07 61 01 Copper Roof System | Aug-2009 | R | Compliance with CSI SectionFormat | |
Jan-2007 | S | UFGS 07 60 00.00 40 Flashing and Sheet Metal | Oct-2006 | D | Superseded by UFGS 07 60 00 Flashing and Sheet Metal (Preparing Activity: Navy) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2006 | S | UFGS 07 60 00.00 40 Flashing and Sheet Metal | Oct-2006 | R | Various minor revisions | |
Jun-2006 | S | UFGS 07 60 00.00 40 Flashing and Sheet Metal | Jun-2006 | R | Reference Update | |
May-2017 | N | UFGS 07 60 00 Flashing and Sheet Metal | May-2017 | R | Addressed CCR 3360 which establishes Energy Star requirements. | |
Aug-2008 | N | UFGS 07 60 00 Flashing and Sheet Metal | Aug-2008 | R | Added note to para 3.5.1 | |
Aug-2018 | N | UFGS 07 60 00 Flashing and Sheet Metal | May-2017 | C | 1 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Jan-2007 | N | UFGS 07 60 00 Flashing and Sheet Metal | Jan-2007 | R | Incorporated NASA Requirements | |
Nov-2018 | N | UFGS 07 60 00 Flashing and Sheet Metal | May-2017 | C | 2 | Added notes for flashing requirements, lead sheet, thickness of aluminum alloy sheet and plate, and fasteners in humid or ESC C3-C5 locations and nailing in ESC C4-C5 locations. |
Aug-2023 | N | UFGS 07 60 00 Flashing and Sheet Metal | Aug-2023 | R | Complete review and update including the incorporation of CCRs. | |
Aug-2017 | N | UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing | May-2011 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2010 | N | UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing | Aug-2010 | R | Added GEI or SCS certification | |
Aug-2009 | N | UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing | Aug-2009 | R | Minor revisions | |
May-2013 | N | UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing | May-2011 | C | 1 | modified subpart 1.4.6 |
May-2011 | N | UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing | May-2011 | R | Reference update: modified tables in subparts 2.2.3 and 2.2.4 | |
Aug-2018 | N | UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing | May-2011 | C | 3 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Feb-2023 | N | UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing | May-2011 | C | 4 | In response to CCR 12504, updated SUBMITTALS article and SPRAY URETHANE FOAM paragraph (2.2) to disallow all HFC blowing agents. |
Jan-2007 | N | UFGS 07 55 23 Ethylene Propylene Diene Monomer (EPDM) Roofing Membrane | Jul-2006 | D | Superseded by UFGS 07 53 23 Ethylene-Propylene-Diene Monomer Roofing Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2006 | N | UFGS 07 55 23 Ethylene Propylene Diene Monomer (EPDM) Roofing Membrane | Jul-2006 | R | Added NASA requirements | |
Aug-2009 | A | UFGS 07 55 00 Protected Membrane Roofing (PMR) | Aug-2009 | R | Compliance with CSI SectionFormat | |
May-2014 | A | UFGS 07 55 00 Protected Membrane Roofing (PMR) | Aug-2009 | C | 1 | Energy efficiency requirements added |
Aug-2017 | A | UFGS 07 54 19 Polyvinyl Chloride Roofing | Feb-2013 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Feb-2013 | A | UFGS 07 54 19 Polyvinyl Chloride Roofing | Feb-2013 | R | Title revision and complete update | |
Nov-2008 | A | UFGS 07 54 19 Polyvinyl Chloride Roofing | Nov-2008 | R | Complete revision of section | |
Aug-2018 | A | UFGS 07 54 19 Polyvinyl Chloride Roofing | Feb-2013 | C | 2 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Feb-2021 | A | UFGS 07 54 19 Polyvinyl Chloride Roofing | Feb-2013 | C | 3 | Updated NRCA reference in response to CCR 9568. |
Aug-2023 | A | UFGS 07 54 19 Polyvinyl Chloride Roofing | Aug-2023 | R | Complete review and update. | |
Aug-2017 | N | UFGS 07 53 23 Ethylene-Propylene-Diene-Monomer Roofing | May-2012 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
May-2012 | N | UFGS 07 53 23 Ethylene-Propylene-Diene-Monomer Roofing | May-2012 | R | Major revision | |
Nov-2008 | N | UFGS 07 53 23 Ethylene-Propylene-Diene-Monomer Roofing | Nov-2008 | R | Reference changed from FM AS 4470 to FM 4470 | |
Aug-2018 | N | UFGS 07 53 23 Ethylene-Propylene-Diene-Monomer Roofing | May-2012 | C | 2 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Jan-2007 | N | UFGS 07 53 23 Ethylene-Propylene-Diene-Monomer Roofing | Jan-2007 | N | New section; Incorporated NASA requirements | |
Jan-2007 | S | UFGS 07 53 00.00 40 Elastomeric Membrane Roofing | Oct-2006 | D | Superseded by UFGS 07 53 23 Ethylene-Propylene-Diene Monomer Roofing (Preparing Activity: Navy) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2006 | S | UFGS 07 53 00.00 40 Elastomeric Membrane Roofing | Oct-2006 | R | Various minor revisions | |
Jun-2006 | S | UFGS 07 53 00.00 40 Elastomeric Membrane Roofing | Jun-2006 | R | Title changed from SINGLE PLY MEMBRANE ROOFING; References updated | |
Jan-2007 | S | UFGS 07 52 00.00 40 Modified Bituminous Membrane Protection | Oct-2006 | D | Superseded by UFGS 07 52 00 Modified Bituminous Membrane Roofing (Preparing Activity: Navy) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2006 | S | UFGS 07 52 00.00 40 Modified Bituminous Membrane Protection | Oct-2006 | R | Various minor revisions, Reference Update | |
Jun-2006 | S | UFGS 07 52 00.00 40 Modified Bituminous Membrane Protection | Jun-2006 | R | Reference Update | |
Aug-2017 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | May-2012 | C | 3 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2014 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | May-2012 | C | 2 | Fixed typo under "Substrate Preparation. Changed "Don not" to "Do not" |
Aug-2013 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | May-2012 | C | 1 | Modified note before Part 1, subparts 1.2, 1.7.1, 1.9.1, 1.12, 2.1 efg |
May-2012 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | May-2012 | R | Major revision | |
Nov-2008 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | Nov-2008 | R | Reference changed from FM AS 4470 to FM 4470 | |
Aug-2018 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | May-2012 | C | 4 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Jan-2007 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | Jan-2007 | R | Incorporated NASA requirements | |
Apr-2006 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | Apr-2006 | R | Added English and metric tags throughout. | |
Nov-2019 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | May-2012 | C | 5 | Added notes throughout the specification and notes to the specifier prohibiting torch application of the roofing system when the roof deck, the materials used in the installation of the roofing system, or the existing roof deck or materials are combustible as defined by NFPA 101. Added required submittal to Submittals Article (1.3) of torch applicators CERTA card. Added requirement in paragraph "Preroofing Conference" (1.4.8-g). for torch operator to attend the preroofing conference. Added requirement in paragraph "Fire Watch" (1.7.2) for the use of thermal heat imager during the firewatch. |
Jan-2007 | S | UFGS 07 51 13.13 40 Cold Applied Built-Up Asphalt Roofing | Oct-2006 | D | Superseded by 07 51 13 Built-Up Asphalt Roofing (Preparing Activity: Navy) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2006 | S | UFGS 07 51 13.13 40 Cold Applied Built-Up Asphalt Roofing | Oct-2006 | R | Various minor revisions, Reference Update | |
Jun-2006 | S | UFGS 07 51 13.13 40 Cold Applied Built-Up Asphalt Roofing | Jun-2006 | R | Title changed from BUILT-UP ASPHALT ROOFING; References updated | |
May-2012 | N | UFGS 07 51 13 Built-Up Asphalt Roofing | May-2012 | R | Modified subpart 1.4.4. | |
Nov-2008 | N | UFGS 07 51 13 Built-Up Asphalt Roofing | Nov-2008 | R | Reference changed from FM AS 4470 to FM 4470 | |
Feb-2012 | N | UFGS 07 51 13 Built-Up Asphalt Roofing | Feb-2012 | R | Modified subparts 1.3, 1.4, 1.4.3, 1.4.4, 1.8, 2.14, 3.1, 3.3.8, 3.3.10, 3.5.1, 3.5.2, 3.7; added 1.4.2, 1.10-1.12, 2.11.2; deleted 2.11.1, 3.3.9 | |
Aug-2018 | N | UFGS 07 51 13 Built-Up Asphalt Roofing | May-2012 | C | 1 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Jan-2007 | N | UFGS 07 51 13 Built-Up Asphalt Roofing | Jan-2007 | R | Title changed from Asphalt Built-Up Roofing; Incorporated NASA requirements; Superseding 07 51 13.13 40 Cold Applied Built-Up Asphalt Roofing | |
Nov-2018 | N | UFGS 07 51 13 Built-Up Asphalt Roofing | May-2012 | C | 2 | Added notes restricting use of coral gravel in humid and ESC C3-C5 locations and gravel surface cap sheet in humid and ESC C4-C5 locations. |
Jan-2008 | S | UFGS 07 46 19.00 40 Steel Siding | Jul-2007 | D | Superseded by UFGS 07 42 13 Metal Wall Panels Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | S | UFGS 07 46 19.00 40 Steel Siding | Jul-2007 | R | Reference Update | |
Aug-2017 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | May-2011 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Feb-2018 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | May-2011 | C | 3 | In response to CCRs 1529 and 3187 |
Aug-2010 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | Aug-2010 | R | Added GEI or SCS certification and other minor revisions | |
Jan-2008 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | Jan-2008 | N | Superseding UFGS 07 40 00.00 40 Roofing and Siding Panels and UFGS 07 61 13.00 10 Structural Standing Seam Metal Roof (SSSMR) System | |
May-2013 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | May-2011 | C | 1 | modified subpart 1.5.10 |
May-2011 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | May-2011 | R | Reference update: modified subparts 1.3.1 and 2.1.5 | |
Aug-2020 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | May-2011 | C | 4 | In response to CCR 8748, "Qualifications of Manufacturer" and "Qualification of Installer" were removed from SD-07 in the Submittal Article since both are already listed under SD-01. |
Aug-2017 | N | UFGS 07 42 13 Metal Wall Panels | May-2011 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
May-2011 | N | UFGS 07 42 13 Metal Wall Panels | May-2011 | R | Reference update: modified subparts 2.2.3.6 and 2.5.4.2 | |
Feb-2018 | N | UFGS 07 42 13 Metal Wall Panels | May-2011 | C | 2 | In response to CCR 3731 |
Nov-2010 | N | UFGS 07 42 13 Metal Wall Panels | Nov-2010 | R | Minor revisions throughout | |
Jan-2008 | N | UFGS 07 42 13 Metal Wall Panels | Jan-2008 | R | Added USACE and NASA requirements; Superseding UFGS 07 40 00.00 40 Roofing and Siding Panels and UFGS 07 46 19.00 40 Steel Siding. | |
Apr-2006 | N | UFGS 07 42 13 Metal Wall Panels | Apr-2006 | R | Added English and metric tags throughout; added metric measurements when missing. | |
May-2009 | S | UFGS 07 41 63 Fabricated Roof Panel Assemblies | May-2009 | R | General update | |
Jan-2008 | S | UFGS 07 41 63 Fabricated Roof Panel Assemblies | Jan-2008 | N | Superseding UFGS 07 40 00.00 40 Roofing and Siding Panels and UFGS 07 61 13.00 10 Structural Steel Standing Seam Metal Roof (SSSMR) System | |
Nov-2012 | S | UFGS 07 41 63 Fabricated Roof Panel Assemblies | May-2009 | C | 1 | Tri-Annual Database Maintenance which includes, updating CSI Section Format per latest UFC 1-300-02; Submittal Article compliance, Imperative language and a few minor changes |
Nov-2016 | S | UFGS 07 41 63 Fabricated Roof Panel Assemblies | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
May-2023 | A | UFGS 07 41 63 Fabricated Roof Panel Assemblies | Nov-2016 | C | Administrative Change: Preparing Activity changed from NASA to USACE. | |
Aug-2015 | A | UFGS 07 41 13.16 Copper Roof Panels | Aug-2009 | R | Superseding UFGS 07 61 01 Copper Roof System; Nontechnical number and title revision; Did not change Section date. | |
May-2011 | N | UFGS 07 41 13 Metal Roof Panels | May-2011 | R | Reference update: modified General Note and subparts 1.2.1 and 2.2 | |
Jan-2008 | N | UFGS 07 41 13 Metal Roof Panels | Jan-2008 | R | Title changed from Non-Structural Metal Roofing; Added USACE and NASA requirements; Superseding UFGS 07 40 00.00 40 Roofing and Siding Panels, UFGS 07 61 14.00 20 Steel Standing Seam Roofing, and UFGS 07 61 15.00 20 Aluminum Steel Standing Seam Rooming | |
Nov-2008 | N | UFGS 07 41 13 Metal Roof Panels | Nov-2008 | R | Reference change/update per CCR | |
Aug-2018 | N | UFGS 07 41 13 Metal Roof Panels | May-2011 | C | 1 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Nov-2018 | N | UFGS 07 41 13 Metal Roof Panels | May-2011 | C | 2 | Added notes for gauge requirements of Aluminum and Steel Sheet Panels in humid and ESC C3-C5 locations. |
Aug-2020 | N | UFGS 07 41 13 Metal Roof Panels | May-2011 | C | 3 | In response to CCR 8778, updated supporting steel tolerances to reflect industry standards in paragraph "Erection Tolerances" (3.8.1). |
Feb-2021 | N | UFGS 07 41 13 Metal Roof Panels | May-2011 | C | 4 | In response to CCR 9492, updated paragraph (3.13) WARRANTY by removing "USACE" from the title and requirements for future contracts and arbitration. |
Jan-2008 | S | UFGS 07 40 00.00 40 Roofing and Siding Panels | Jul-2007 | D | Superseded by UFGS 07 41 13 Metal Roof Panels , UFGS 07 41 63 Fabricated Roof Panel Assemblies, UFGS 07 42 13 Metal Wall Panels. and UFGS 07 42 63 Fabricated Wall Panel Assemblies Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |