Related Materials: Policy on UFGS Changes and Revisions
Below is a listing of the Revisions and Changes made to UFGS Sections for each quarterly release.
To view a list for a specific UFGS Release, select the UFGS release date from the 'Release' drop-down and click 'Apply'.
To view a list of all the revisions and changes made to a specific UFGS Section, select 'Any' from the "Release' drop down, type the Section number into the Search bar and select the Section to view, then click 'Apply'.
After clicking 'Apply', you can PRINT REPORT, which will include the nature of the change/revision.
To view the complete detailed history of all the revisions and changes made to a UFGS Section, click on the Section title.
KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA |
---|---|---|---|---|---|
ACTION | N New | R Revision | C Change | D Deletion |
Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
---|---|---|---|---|---|---|
Apr-2008 | S | UFGS 42 23 13.00 40 Process Condensers | Apr-2008 | R | Section References (SRF) update | |
Jul-2007 | S | UFGS 42 23 13.00 40 Process Condensers | Jul-2007 | R | Reference Update | |
Apr-2007 | N | UFGS 01 30 00 Administrative Requirements | Apr-2007 | R | Deleted insurance requirements for NAVFAC Pacific. | |
Apr-2007 | S | UFGS 03 30 00.00 40 Cast-in-Place Concrete | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 03 30 53.00 40 Miscellaneous Cast-in-Place Concrete | Apr-2007 | R | Reference Update | |
Apr-2007 | N | UFGS 03 31 29 Marine Concrete with Service Life Modeling | Apr-2007 | R | Deleted superfluous note under Submittal Article, SD-07. | |
Apr-2007 | S | UFGS 03 41 33.00 40 Precast Structural Pretensioned Concrete | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 03 45 00.00 40 Precast Architectural Concrete | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 03 50 00.00 40 Cast Decks and Underlayments | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 05 14 00.13 Welding Structural Aluminum Framing | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 05 51 00.00 40 Metal Stairs | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 05 70 00.00 40 Decorative Metals | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 06 18 00 Glued-Laminated Construction | Apr-2007 | R | Titled changed from GLUE-LAMINATED STRUCTURAL UNITS; Reference Update | |
Apr-2007 | S | UFGS 07 40 00.00 40 Roofing and Siding Panels | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 08 13 73.00 40 Sliding Metal Doors | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 08 44 00.00 40 Curtain Wall and Glazed Assemblies | Apr-2007 | R | Section References (SRF) update | |
Apr-2007 | S | UFGS 08 51 13.00 40 Aluminum Windows | Apr-2007 | R | Section References (SRF) update | |
Apr-2007 | S | UFGS 09 30 16.00 40 Quarry Tiling | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 09 67 00.00 40 Fluid-Applied Flooring | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 10 51 00.00 40 Lockers | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 12 30 00.00 40 Casework | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 13 50 00.00 40 Special Instrumentation | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 21 13 00.00 40 Fire-Suppression Sprinkler Systems | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 21 13 26.00 40 Deluge Fire-Suppression Sprinkler Systems | Apr-2007 | R | Reference Update | |
Apr-2007 | N | UFGS 22 00 00 Plumbing, General Purpose | Apr-2007 | R | Added chlorine filters to water supply to Air Force, NASA sinks, lavatories and tubs/showers: Corrected errors in installation heights of urinals and other fixtures. | |
Apr-2007 | S | UFGS 22 15 09 General Service Compressed-Air Systems Cleaning Procedures | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 22 15 13.16 40 High-Pressure Compressed-Air Piping and Valves, Stainless | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 00 00.00 40 Heating, Ventilating, and Air Conditioning | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 05 00.00 40 Common Work Results for HVAC | Apr-2007 | R | Reference Update | |
Apr-2007 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Apr-2007 | R | Minor change to paragraph Vapor Barrier/Weatherproofing Jacket | |
Apr-2007 | N | UFGS 23 08 00.00 20 Commissioning of Mechanical[ and Plumbing] Systems | Apr-2007 | R | Paragraph 1.8.4.2 Certified TAB Reports - list item d: (5) & (6): Reduced number of reporting sites required for medium size duct systems | |
Apr-2007 | N | UFGS 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC | Apr-2007 | R | Revised definitions, added guidance for BACnet Testing Labs (BTL) certification | |
Apr-2007 | S | UFGS 23 09 33.00 40 Electric and Electronic Control System for HVAC | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 11 23.00 40 Facility Natural-Gas Piping | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 23 16.00 40 Refrigerant Piping Specialties | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 41 13.00 40 Panel Filters | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 52 00.00 40 Heating Boilers | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 74 33.00 40 Small HVAC Units, Cooling-Only, Recirculating, Split and Unitary for Window and Floor Mounting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 81 43.00 40 Air-Source Unitary Heat Pumps | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 82 19.00 40 Fan Coil Units | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 82 23.00 40 Unit Ventilators | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 05 13.00 10 Medium-Voltage Cables | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 05 73.00 40 Overcurrent Protective Devices | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 12 00.00 40 Medium-Voltage Transformers | Apr-2007 | R | Reference Update | |
Apr-2007 | N | UFGS 26 32 13.00 20 Single Operation Generator Sets | Apr-2007 | R | Section note revised to add Capital Improvements requirements | |
Apr-2007 | S | UFGS 26 51 13.08 40 Incandescent Lighting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 51 13.09 40 Fluorescent Luminaries | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 54 00.00 40 Classified, Special Purpose, Exterior Lighting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 56 19.00 40 Roadway Lighting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 56 36.00 40 Flood Lighting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 28 05 26.00 40 Grounding and Bonding for Electrical Systems | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 28 33 00.00 40 Fuel-Gas Detection and Alarm | Apr-2007 | R | Reference Update | |
Apr-2007 | A | UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields | Apr-2007 | R | VMA and joints | |
Apr-2007 | S | UFGS 33 32 13.13 40 Packaged Sewage Lift Stations, Wet Well Type | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 33 40 00.00 40 Storm Drainage Utilities | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 33 75 00.00 40 Switchgear and Protection Devices | Apr-2007 | R | Section References (SRF) update | |
Apr-2007 | S | UFGS 40 18 00.00 40 Vacuum Systems Process Piping | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 40 95 33.23 40 Fiber Optic Process Control Networks | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 42 22 00.00 40 Process Chillers and Coolers | Apr-2007 | R | Reference Update | |
Jan-2007 | N | UFGS 00 01 15 List of Drawings | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | N | UFGS 00 22 13 Supplementary Instructions to Bidders | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | N | UFGS 00 41 00 Bid Schedules | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | A | UFGS 01 32 01.00 10 Project Schedule | Jan-2007 | R | Added Design-Build tailoring option | |
Jan-2007 | N | UFGS 01 32 17.00 20 Cost-Loaded Network Analysis Schedules (NAS) | Jan-2007 | R | Deleted [DESIGN BUILD] from the title and Design-Build requirements from the section. | |
Jan-2007 | N | UFGS 01 45 00.00 20 Quality Control | Jan-2007 | R | Removed reference to UFGS 01 99 00 in paragraph Commissioning (1.4.1) | |
Jan-2007 | N | UFGS 01 58 00 Project Identification | Jan-2007 | R | Revised link to NAVFAC logo | |
Jan-2007 | A | UFGS 01 74 19 Construction Waste Management and Disposal | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | S | UFGS 03 30 00.00 40 Cast-in-Place Concrete | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | S | UFGS 03 41 33.00 40 Precast Structural Pretensioned Concrete | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | S | UFGS 03 47 00.00 40 Site-Cast Concrete | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | S | UFGS 05 51 00.00 40 Metal Stairs | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | N | UFGS 07 16 19 Metallic Oxide Waterproofing | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | N | UFGS 07 22 00 Roof and Deck Insulation | Jan-2007 | R | Incorporated NASA requirements | |
Jan-2007 | S | UFGS 07 22 00.00 40 Roof and Deck Insulation | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | N | UFGS 07 51 13 Built-Up Asphalt Roofing | Jan-2007 | R | Title changed from Asphalt Built-Up Roofing; Incorporated NASA requirements; Superseding 07 51 13.13 40 Cold Applied Built-Up Asphalt Roofing | |
Jan-2007 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | Jan-2007 | R | Incorporated NASA requirements | |
Jan-2007 | N | UFGS 07 60 00 Flashing and Sheet Metal | Jan-2007 | R | Incorporated NASA Requirements | |
Jan-2007 | N | UFGS 07 92 00 Joint Sealants | Jan-2007 | R | Incorporated NASA requirements | |
Jan-2007 | N | UFGS 08 11 73 Sliding Fire Doors | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | S | UFGS 08 13 73.00 40 Sliding Metal Doors | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | S | UFGS 08 44 00.00 40 Curtain Wall and Glazed Assemblies | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | A | UFGS 09 30 00 Ceramic Tile, Quarry Tile, and Paver Tile | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | A | UFGS 09 65 00 Resilient Flooring | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | A | UFGS 09 68 00 Carpeting | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | N | UFGS 09 97 13.16 Interior Coating of Welded Steel Water Tanks | Jan-2007 | R | Extensive rewrite. | |
Jan-2007 | N | UFGS 09 97 13.17 Three Coat Epoxy Interior Coating of Welded Steel Petroleum Fuel Tanks | Jan-2007 | R | Extensive rewrite | |
Jan-2007 | N | UFGS 09 97 13.27 High Performance Coating for Steel Structures | Jan-2007 | R | Extensive rewrite | |
Jan-2007 | A | UFGS 10 21 13 Toilet Compartments | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | A | UFGS 12 50 00 Furniture Systems | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | S | UFGS 13 50 00.00 40 Special Instrumentation | Jan-2007 | R | Section References (SRF) update | |
Feb-2007 | A | UFGS 21 30 00 Fire Pumps | Feb-2007 | R | INTERIM RELEASE: Corrected metric conversion | |
Jan-2007 | N | UFGS 22 00 00 Plumbing, General Purpose | Jan-2007 | R | Revised non-water use urinals | |
Jan-2007 | A | UFGS 22 04 00.00 10 Plumbing, Hospital | Jan-2007 | R | Added non-water using urinal | |
Oct-2006 | S | UFGS 23 00 00.00 40 Heating, Ventilating, and Air Conditioning | Oct-2006 | R | Section References (SRF) update | |
Jan-2007 | N | UFGS 23 03 00.00 20 Basic Mechanical Materials and Methods | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Jan-2007 | R | Added jacketing system | |
Feb-2007 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Feb-2007 | R | INTERIM RELEASE: Corrected permeability | |
Jan-2007 | S | UFGS 23 55 13.00 40 Fuel-Fired Duct Heaters | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | N | UFGS 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems | Jan-2007 | R | Added note "Not for use in Navy projects" to paragraphs 'Piping for Steam and Condensate' (2.3) and 'Piping for High-Pressure Compressed-Air Systems' (2.4) | |
Jan-2007 | N | UFGS 23 81 47 Water-Loop and Ground-Loop Heat Pump Systems | Jan-2007 | R | Title changed from Vertical Ground-Coupled Heat Exchange Systems; Superseding UFGS 23 81 46.00 20 Water Source Heat Pump Systems (requirements incorporated) |