Related Materials: Policy on UFGS Changes and Revisions
Below is a listing of the Revisions and Changes made to UFGS Sections for each quarterly release.
To view a list for a specific UFGS Release, select the UFGS release date from the 'Release' drop-down and click 'Apply'.
To view a list of all the revisions and changes made to a specific UFGS Section, select 'Any' from the "Release' drop down, type the Section number into the Search bar and select the Section to view, then click 'Apply'.
After clicking 'Apply', you can PRINT REPORT, which will include the nature of the change/revision.
To view the complete detailed history of all the revisions and changes made to a UFGS Section, click on the Section title.
KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA |
---|---|---|---|---|---|
ACTION | N New | R Revision | C Change | D Deletion |
Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
---|---|---|---|---|---|---|
Nov-2023 | A | UFGS 12 48 13 Entrance Floor Mats and Frames | Aug-2023 | C | Administrative Change: Preparing Activity changed from NASA to USACE. | |
Nov-2023 | A | UFGS 26 05 13.00 10 Medium-Voltage Cables | Nov-2023 | N | Renumbered/Superseded NASA UFGS-26 05 13.00 40 without revision | |
Nov-2023 | A | UFGS 26 05 48.00 10 Seismic Protection for Electrical Equipment | Oct-2007 | D | Superseded by UFGS-26 05 48 SEISMIC PROTECTION FOR ELECTRICAL EQUIPMENT | |
Nov-2023 | A | UFGS 26 55 53 Security Lighting | Nov-2023 | N | Renumbered/Superseded NASA UFGS-26 55 53.00 40 without revision | |
Nov-2023 | A | UFGS 26 22 00.00 10 480-Volt Station Service Switchgear and Transformers | Nov-2023 | R | Complete review and update. | |
Nov-2023 | A | UFGS 32 01 11.51 Rubber and Paint Removal From Airfield Pavements | Nov-2023 | R | Complete review and update. | |
Nov-2023 | A | UFGS 32 01 13.62 Bituminous Surface Treatment [and] [Sand Seal] | Nov-2023 | R | Complete review and update, including section title change from ASPHALT SURFACE TREATMENT to BITUMINOUS SURFACE TREATMENT [AND] [SAND SEAL]. | |
Nov-2023 | A | UFGS 32 01 13.64 Rejuvenation of Asphalt Pavement Surfaces | Nov-2023 | R | Complete review and update, including section title change from BITUMINOUS PAVEMENT LIQUID REJUVENATING to REJUVENATION OF ASPHALT PAVEMENT SURFACES. | |
Nov-2023 | A | UFGS 32 01 18.71 Grooving of Airfield Paving | Nov-2023 | R | Complete review and update. Added new Related Materials. | |
Nov-2023 | A | UFGS 32 12 36.13 Bituminous Fog Seal | Nov-2023 | R | Complete review and update, including section title change from ASPHALTIC SEAL AND FOG COATS to BITUMINOUS FOG SEAL. | |
Nov-2023 | A | UFGS 35 05 40.14 10 Hydraulic Power Systems for Civil Works Structures | Nov-2023 | R | Superseding UFGS-41 24 26 HYDRAULIC POWER SYSTEMS. Complete review and update. | |
Nov-2023 | A | UFGS 35 31 19 Stone, Channel, Shoreline/Coastal Protection for Structures | Nov-2023 | R | Complete review and update. | |
Nov-2023 | A | UFGS 35 31 19.20 Articulating Concrete Block Revetments | Nov-2023 | R | Complete review and update. | |
Nov-2023 | A | UFGS 41 24 26 Hydraulic Power Systems | May-2020 | D | Superseded by UFGS-35 05 40.14 10 HYDRAULIC POWER SYSTEMS FOR CIVIL WORKS STRUCTURES. | |
Nov-2023 | A | UFGS 48 06 15 Turbine Oil | Nov-2023 | R | Complete review and update. | |
Nov-2023 | A | UFGS 03 37 29 Concrete for Concrete Cutoff Walls | Nov-2009 | C | 1 | Incorporated CCR #12904. |
Nov-2023 | A | UFGS 32 01 17.61 Sealing Cracks in Asphalt Paving | May-2022 | C | 1 | Incorporated CCR #13888. |
Nov-2023 | A | UFGS 26 05 48 Seismic Protection for Electrical Equipment | Nov-2023 | N | New Unified Section; Superseding UFGS-26 05 48.00 10 SEISMIC PROTECTION FOR ELECTRICAL EQUIPMENT. | |
Nov-2023 | A | UFGS 26 13 32 Medium-Voltage Switchgear, Gas-Insulated | Nov-2023 | N | New UFGS Section | |
Feb-2024 | A | UFGS 01 42 15 Metric Measurements | Feb-2024 | R | Complete review and update. | |
Feb-2024 | A | UFGS 11 13 19.13 Loading Dock Levelers | Feb-2024 | R | Complete review and update. | |
Feb-2024 | A | UFGS 23 33 56 Self-Acting Blast Valves | Feb-2009 | D | Archived with no replacement. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2024 | A | UFGS 26 37 13 Microgrid Control System | Feb-2024 | N | New UFGS Section | |
Feb-2024 | A | UFGS 33 05 07.13 Utility Directional Drilling | Feb-2024 | N | New UFGS section superseding UFGS-33 05 23.13 UTILITY HORIZONTAL DIRECTIONAL DRILLING | |
May-2017 | F | UFGS 48 14 00 Solar Photovoltaic Systems | May-2017 | N | New Section. | |
May-2016 | F | UFGS 33 12 33.00 30 Water Meters | Nov-2011 | C | 1 | Section retitled from WATER UTILITY METERING |
Nov-2014 | F | UFGS 26 27 13.10 30 Electric Meters | Oct-2007 | C | 1 | Corrected tagging error in paragraph 2.1.4 e. |
May-2010 | F | UFGS 33 51 13.00 30 Natural-Gas Metering | May-2010 | N | New section | |
Aug-2008 | F | UFGS 33 12 33.00 30 Water Meters | Aug-2008 | N | New Section | |
May-2011 | F | UFGS 26 05 71.00 40 Low-Voltage Overcurrent Protective Devices | May-2011 | R | CCR 404: Minor revisions | |
Nov-2011 | F | UFGS 33 12 33.00 30 Water Meters | Nov-2011 | R | Section retitled from WATER METERS | |
Aug-2018 | F | UFGS 26 27 13.10 30 Electric Meters | Oct-2007 | C | 2 | Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures. |
Oct-2007 | F | UFGS 26 27 13.10 30 Electric Meters | Oct-2007 | N | New section | |
Jul-2007 | F | UFGS 23 14 00 Commissioning of Fuel Facility Systems | Apr-2007 | D | Superseded by UFGS 33 08 55 Commissioning of Fuel Facility Systems Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | F | UFGS 23 14 00 Commissioning of Fuel Facility Systems | Apr-2007 | N | New section | |
Feb-2020 | F | UFGS 33 12 33.00 30 Water Meters | Nov-2011 | D | Section is no longer needed. All water meter requirements are covered in UFGS 33 11 00 WATER UTILITY DISTRIBUTION PIPING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2022 | F | UFGS 32 31 13 Chain Link Fences and Gates | Nov-2021 | C | Administrative Change: Preparing Activity changed from NASA to Air Force. | |
Nov-2022 | F | UFGS 33 05 23.13 Utility Horizontal Directional Drilling | Nov-2019 | C | Administrative Change: Preparing Activity changed from NASA to Air Force. | |
Nov-2019 | F | UFGS 33 32 16 Packaged Utility Wastewater Pumping Stations | Nov-2022 | C | Administrative Change: Preparing Activity changed from NASA to Air Force. | |
Nov-2022 | F | UFGS 33 51 39 Monitoring Wells | Aug-2017 | C | Administrative Change: Preparing Activity changed from NASA to Air Force. | |
Nov-2023 | F | UFGS 33 32 16 Packaged Utility Wastewater Pumping Stations | Nov-2019 | C | 1 | Incorporated various CCRs. |
Aug-2017 | N | UFGS 01 14 00 Work Restrictions | Nov-2011 | C | 4 | Incorporation of DBIDS procedures for access to NAVY Installations. |
Aug-2017 | N | UFGS 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC | Nov-2015 | D | Archived to meet the requirement of 10 USC 2867 to adopt a "Department-wide, Open Protocol, Energy Monitoring and Utility Control System Specification" for use in military construction and military family housing activities. UFGS 25 10 10 Utility Monitoring and Control System (UMCS) Front End and Integration was published to meet this requirement. The following UFGSs were also published to meet this requirement and superseded Section 23 09 23.13 20: 23 09 00 INSTRUMENTATION AND CONTROL FOR HVAC, 23 09 13 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC, 23 09 23.01 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING CONTROL SYSTEMS, and 23 09 23.02 BACNET DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING CONTROL SYSTEMS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2017 | N | UFGS 01 31 23.13 20 Electronic Construction and Facility Support Contract Management System (eCMS) | May-2017 | C | 1 | Changed submittal period of Personnel List, personnel roles, and removed Certified Payrolls, Invoice, and Routine Correspondence from Table 1; Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Nov-2017 | N | UFGS 01 33 29 Sustainability Requirements and Reporting | Feb-2017 | C | 2 | Changes are related to Change 01 UFC 1-200-02, and updates. |
Nov-2017 | N | UFGS 01 35 26 Governmental Safety Requirements | Nov-2015 | C | 5 | Addition of lockout/tagout requirements when the Government of Utility is involved in the electrical outage |
Nov-2017 | N | UFGS 08 71 00 Door Hardware | Feb-2016 | C | 1 | In response to CCR 5837 , removed paragraph pertaining to Navy Training Center , Orlando , Florida . |
Nov-2017 | N | UFGS 11 53 00 Laboratory Equipment and Fumehoods | May-2011 | C | 1 | In response to CCR 3026, reference ACGIH-2092S was replaced with ACGIH-2097. |
Nov-2017 | N | UFGS 22 00 00 Plumbing, General Purpose | Nov-2015 | C | 2 | In response to CCR 5954, updated Table I to include condensate drain piping. |
Aug-2017 | N | UFGS 11 05 40 Common Work Results for Foodservice Equipment | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02, reference updates and general revisions. | |
Aug-2017 | N | UFGS 11 06 40.13 Foodservice Equipment Schedule | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02, reference updates and general revisions. | |
Aug-2017 | N | UFGS 11 31 13 Electric Kitchen Equipment | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02, reference updates and general revisions. | |
Aug-2017 | N | UFGS 11 41 11 Refrigerated and Frozen Food Storage Equipment | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02, reference updates and general revisions. | |
Aug-2017 | N | UFGS 11 42 00 Food Preparation Equipment | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02, reference updates and general revisions. | |
Aug-2017 | N | UFGS 11 48 00 Cleaning and Disposal Equipment | Aug-2017 | R | Addressed CCR 3360 which establishes Energy Star requirements . | |
Aug-2017 | N | UFGS 32 05 33 Landscape Establishment | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions. | |
Aug-2017 | N | UFGS 32 92 19 Seeding | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions. | |
Aug-2017 | N | UFGS 32 92 26 Sprigging | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions. | |
Aug-2017 | N | UFGS 32 93 00 Exterior Plants | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions. | |
Aug-2017 | N | UFGS 32 96 00 Transplanting Exterior Plants | Aug-2017 | R | Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions. | |
Aug-2017 | N | UFGS 01 45 00.00 20 Quality Control | Nov-2011 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 01 45 00.10 20 Quality Control for Minor Construction | Feb-2010 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 02 82 16.00 20 Engineering Control of Asbestos Containing Materials | Aug-2011 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 03 30 00 Cast-In-Place Concrete | May-2014 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 03 31 29 Marine Concrete with Service Life Modeling | Aug-2012 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 05 51 33 Metal Ladders | Feb-2016 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 06 13 33 Pier Timberwork | Nov-2016 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 13 53 Elastomeric Sheet Waterproofing | Feb-2016 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 14 00 Fluid-Applied Waterproofing | Feb-2012 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 19 00 Water Repellents | May-2011 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 24 00 Exterior Insulation and Finish Systems | May-2011 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 42 13 Metal Wall Panels | May-2011 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 42 63 Fabricated Wall Panel Assemblies | May-2011 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | May-2012 | C | 3 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 53 23 Ethylene-Propylene-Diene-Monomer Roofing | May-2012 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing | May-2011 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 07 92 00 Joint Sealants | Aug-2016 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 09 29 00 Gypsum Board | Aug-2016 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 09 67 23.15 Fuel Resistive Resinous Flooring, 3-Coat System | Aug-2010 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 09 67 23.16 Fuel Resistive Resinous Flooring, 5-Coat System | Aug-2010 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 09 90 00 Paints and Coatings | May-2011 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 09 96 59 High-Build Glaze Coatings | May-2011 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 09 97 13.16 Interior Coating of Welded Steel Water Tanks | May-2011 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 09 97 13.17 Three Coat Epoxy Interior Coating of Welded Steel Petroleum Fuel Tanks | Feb-2010 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 09 97 13.27 High Performance Coating for Steel Structures | Oct-2016 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 09 97 23.13 Interior Lining For Concrete Storage Tanks (For Petroleum Fuels) | May-2011 | C | 1 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 23 09 53.00 20 Space Temperature Control Systems | Feb-2010 | C | 2 | Updated to coordinate archiving of Navy Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide, Open Protocol, Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities. |
Aug-2017 | N | UFGS 23 35 19.00 20 Industrial Ventilation and Exhaust | Feb-2010 | C | 1 | Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions. |
Aug-2017 | N | UFGS 23 52 33.02 20 Steam Heating Plant Watertube (Field Erected) Coal/Oil or Coal | Nov-2008 | C | 3 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 23 52 33.03 20 Water-Tube Boilers, Oil/Gas or Oil | Nov-2008 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 23 64 00 Packaged Water Chillers, Absorption Type | Nov-2016 | C | 1 | Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide, Open Protocol, Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities. |
Aug-2017 | N | UFGS 23 64 10 Water Chillers, Vapor Compression Type | Nov-2016 | C | 1 | Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide, Open Protocol, Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities. |
Aug-2017 | N | UFGS 23 65 00 Cooling Towers and Remote Evaporatively-Cooled Condensers | Nov-2016 | C | 1 | Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide, Open Protocol, Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities. |
Aug-2017 | N | UFGS 23 81 00.00 20 Unitary Air Conditioning Equipment | Nov-2009 | C | 3 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 23 81 23.00 20 Computer Room Air Conditioning Units | Feb-2010 | C | 2 | Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 23 81 47 Water-Loop and Ground-Loop Heat Pump Systems | Aug-2008 | C | 3 | Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide, Open Protocol, Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities. Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS). |
Aug-2017 | N | UFGS 25 50 00.00 20 Cybersecurity of Facility-Related Control Systems | Feb-2017 | C | 2 | Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide, Open Protocol, Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities. |
Aug-2017 | N | UFGS 26 11 13.00 20 Primary Unit Substation | Apr-2007 | C | 1 | Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide, Open Protocol, Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities. |
Aug-2017 | N | UFGS 26 11 16 Secondary Unit Substations | Feb-2010 | C | 1 | Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide , Open Protocol , Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities. |
Aug-2017 | N | UFGS 26 20 00 Interior Distribution System | Feb-2014 | C | 1 | Updated to coordinate archiving of Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a “Department wide, Open Protocol, Energy Monitoring and Utility Control System Specification” for use in military construction and military family housing activities. |