UFGS Changes and Revisions  Subscribe to UFGS Changes and Revisions

Related Materials: Policy on UFGS Changes and Revisions

Below is a listing of the Revisions and Changes made to UFGS Sections for each quarterly release.

To view a list for a specific UFGS Release, select the UFGS release date from the 'Release' drop-down and click 'Apply'.

To view a list of all the revisions and changes made to a specific UFGS Section, select 'Any' from the "Release' drop down, type the Section number into the Search bar and select the Section to view, then click 'Apply'.

After clicking 'Apply', you can PRINT REPORT, which will include the nature of the change/revision.

To view the complete detailed history of all the revisions and changes made to a UFGS Section, click on the Section title.

KEY PREPARING ACTIVITY (PA) A Army N Navy F Air Force S NASA
ACTION N New R Revision C Change D Deletion
Release PA UFGS Sectionsort ascending Action Change # Nature of Change or Revision
Apr-2008 A UFGS 32 13 17 Stone Matrix Asphalt (SMA) for Airfield Pavements R Revised througout
Aug-2008 A UFGS 32 13 17 Stone Matrix Asphalt (SMA) for Airfield Pavements R Compliance with CSI SectionFormat
Jan-2007 A UFGS 32 13 17 Stone Matrix Asphalt (SMA) for Airfield Pavements R Changed design requirements
Feb-2019 A UFGS 32 13 17 Stone Matrix Asphalt (SMA) for Airfield Pavements D Superseded by UFGS 32 12 15.16 STONE MATRIX ASPHALT (SMA) FOR AIRFIELD PAVING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2008 A UFGS 32 13 16.16 Roller Compacted Concrete (RCC) Pavement R Compliance with CSI SectionFormat
Jul-2007 A UFGS 32 13 16.16 Roller Compacted Concrete (RCC) Pavement R Complete revision; added appendices
Nov-2020 A UFGS 32 13 16.16 Roller Compacted Concrete (RCC) Pavement D Superseded by UFGS 32 13 13.17 ROLLER COMPACTED CONCRETE PAVING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2010 A UFGS 32 13 15.20 Concrete Pavement for Fuel Storage Containment Dikes N New section
May-2021 A UFGS 32 13 15.20 Concrete Pavement for Fuel Storage Containment Dikes C 1 Added impermeable liner system requirements in response to CCR 7040.
Nov-2022 A UFGS 32 13 15.20 Concrete Pavement for Fuel Storage Containment Dikes R Complete review and update to include section title change from CONCRETE PAVEMENT FOR CONTAINMENT DIKES to CONCRETE PAVEMENT FOR FUEL STORAGE CONTAINMENT DIKES
Aug-2023 A UFGS 32 13 14.14 Concrete Paving for Small Airfield Projects N New UFGS Section.
Nov-2017 A UFGS 32 13 14.13 Concrete Paving for Airfields and Other Heavy Duty Pavements N Superseding UFGS 32 13 11 Concrete Paving for Airfields and Other Heavy Duty Pavements. Complete review and update including section number and title changes.
Aug-2019 A UFGS 32 13 14.13 Concrete Paving for Airfields and Other Heavy Duty Pavements R Complete review and update.
Nov-2022 A UFGS 32 13 14.13 Concrete Paving for Airfields and Other Heavy Duty Pavements R Complete review and update
Oct-2007 A UFGS 32 13 14 Concrete Pavement for Small Projects D Replaced/Superseded by UFGS 32 13 13.03 Airfields and Heavy Duty Concrete Pavement Less Than 10000 Cubic Yards. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2018 N UFGS 32 13 13.43 High Temperature Concrete Paving for Airfields Using Lightweight and Traprock Aggregates N New UFGS Section
Nov-2020 A UFGS 32 13 13.17 Roller Compacted Concrete Paving N Superseding UFGS 32 13 16.16 ROLLER COMPACTED CONCRETE (RCC) PAVEMENT.
Aug-2017 N UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads and Site Facilities C 2 Sustainability updates, formatting to meet UFC 1-300-02 , reference updates and general revisions.
Nov-2013 N UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads and Site Facilities C 1 Added subparts 1.2, 2.1.1.2, 2.1.1.4 and 2.1.2; Revised subparts 1.4, 1.6.2, 2.1.1, 2.1.3, 2.1.3.1, 2.3, 3.3.7, 3.7.5.1, 3.7.5.2 and 3.7.7
Aug-2008 N UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads and Site Facilities R Minor revisions throughout
Nov-2011 N UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads and Site Facilities R Section retitled from [Pervious] Portland Cement Concrete Pavement for Roads and Site Facilities; Removed Pervious Concrete data throughout which is now contained in UFGS 32 13 43 Pervious Concrete Paving
Jul-2006 N UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads and Site Facilities R Title changed from PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE FACILITIES; Added sustainable design requirements
May-2020 N UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads and Site Facilities R Complete review and update.
Aug-2010 N UFGS 32 13 13.03 Airfields and Heavy-Duty Concrete Pavement Less than 10000 Cubic Yards D Superseded by UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavement Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2017 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements D Superseded by UFGS 32 13 14.13 Concrete Paving for Airfields and Other Heavy Duty Pavements. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2015 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements R UFGS refresh review and update.
Aug-2010 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements R Title changed to eliminate volume restriction; was Concrete Pavement for Airfields and Other Heavy-Duty Pavements More Than 10000 Cubic Yards
Nov-2009 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements R Revisions throughout including, but not limited to, Test Section, Portland Cement, aggregate blending, other finishing equipment and broom finish
Nov-2014 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements C 1 Revised par. 2.2.2.5 as noted in CCR 3847. Revised note in par. 2.4 as noted in CCR 2731.
Apr-2008 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements R Revised throughout
Nov-2012 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements R Update of the entire section
Jul-2007 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements R Revision for diamond grinding and supplemental cements, silica and admixtures
Jul-2006 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements R Various revisions
Aug-2008 A UFGS 32 12 43.16 Porous Friction Course for Airfields and Roads N Superseding UFGS 32 12 20 with same title.
Aug-2017 A UFGS 32 12 43.16 Porous Friction Course for Airfields and Roads D Retired; Section is outdated and no longer needed. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2008 A UFGS 32 12 37 Fuel-Resistant (Coal Tar) Sealer R Compliance with CSI SectionFormat
Aug-2017 A UFGS 32 12 37 Fuel-Resistant (Coal Tar) Sealer D Retired; Section is outdated and no longer needed. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2020 A UFGS 32 12 36.26 Polymer Concrete Micro-Overlay (PCMO) For Fuel And Abrasion Resistant Wearing Surfaces N Superseding UFGS 32 12 36.26 10 POLYMER CONCRETE MICRO-OVERLAY (PCMO) FOR FUEL AND ABRASION RESISTANT WEARING SURFACES without revision. Section number change.
May-2020 A UFGS 32 12 36.26 10 Polymer Concrete Micro-Overlay (PCMO) for Fuel and Abrasion Resistant Wearing Surfaces N Superseding UFGS 32 12 22.00 10 POLYMER CONCRETE MICRO-OVERLAY (PCMO) FOR FUEL AND ABRASION RESISTANT WEARING SURFACES.
Nov-2020 A UFGS 32 12 36.26 10 Polymer Concrete Micro-Overlay (PCMO) for Fuel and Abrasion Resistant Wearing Surfaces D Superseded by UFGS 32 12 36.26 POLYMER CONCRETE MICRO-OVERLAY (PCMO) FOR FUEL AND ABRASION RESISTANT WEARING SURFACES without revision. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 N UFGS 32 12 36.19 Coal Tar Seal with Unvulcanized Rubber D Retired; Section is outdated and no longer needed. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2017 A UFGS 32 12 36.13 Bituminous Fog Seal N Superseding UFGS 32 01 13 Bituminous Seal and Fog Coats; Total review and update.
Nov-2023 A UFGS 32 12 36.13 Bituminous Fog Seal R Complete review and update, including section title change from ASPHALTIC SEAL AND FOG COATS to BITUMINOUS FOG SEAL.
Jun-2006 S UFGS 32 12 29.00 40 Porous Friction Course for [Airfields][ and ][Roads] D Deleted without replacement. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 A UFGS 32 12 22.00 10 Polymer Concrete-Micro-Overlay (PCMO) For Fuel and Abrasion Resistant Wearing Surfaces C 1 Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS).
Aug-2008 A UFGS 32 12 22.00 10 Polymer Concrete-Micro-Overlay (PCMO) For Fuel and Abrasion Resistant Wearing Surfaces R Compliance with CSI SectionFormat
May-2020 A UFGS 32 12 22.00 10 Polymer Concrete-Micro-Overlay (PCMO) For Fuel and Abrasion Resistant Wearing Surfaces D Superseded by UFGS 32 12 36.26 10 POLYMER CONCRETE MICRO-OVERLAY (PCMO) FOR FUEL AND ABRASION RESISTANT WEARING SURFACES. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2018 A UFGS 32 12 21 Bituminous Road-Mix Surface Course D UFGS archived. UFGS is no longer active. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2008 A UFGS 32 12 21 Bituminous Road-Mix Surface Course R Compliance with CSI SectionFormat
Aug-2008 A UFGS 32 12 20 Porous Friction Course for Airfields and Roads D Superseded by UFGS 32 12 43.16 with no title change
Nov-2019 A UFGS 32 12 19.16 Resin-Modified Asphalt Paving Wearing Courses N Complete review and update to meet MF2016 and UFC 1-300-02. Superseding UFGS 32 12 18 RESIN MODIFIED PAVEMENT SURFACING MATERIAL.
Aug-2008 A UFGS 32 12 19 Bituminous Binder and Wearing Courses (Central-Plant Cold-Mix) R Compliance with CSI SectionFormat
Nov-2019 A UFGS 32 12 19 Bituminous Binder and Wearing Courses (Central-Plant Cold-Mix) D Superseded by UFGS 32 12 16.19 COLD-MIX ASPHALT PAVING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2008 A UFGS 32 12 18 Resin Modified Pavement Surfacing Material R Compliance with CSI SectionFormat
Nov-2019 A UFGS 32 12 18 Resin Modified Pavement Surfacing Material D Superseded by UFGS 32 12 19.16 RESIN-MODIFIED ASPHALT PAVING WEARING COURSES. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2020 A UFGS 32 12 17.19 Fuel Resistant Asphalt Paving For Airfields - Surface Course N New UFGS.
May-2018 N UFGS 32 12 17 Hot Mix Bituminous Pavement D Superseded by Section 32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Apr-2008 N UFGS 32 12 17 Hot Mix Bituminous Pavement R Corrected format in para 3.5
Nov-2013 N UFGS 32 12 17 Hot Mix Bituminous Pavement C 1 Revised subparts 1.6.1, 2.2, 2.5.1, 2.5.2, 3.3, 3.5.2.2 and 3.5.2.3
Apr-2008 N UFGS 32 12 16.19 Cold-Mix Asphalt Paving D Changed section number to 32 01 17.62 (with no title change) to agree with CSI MasterFormat 2004 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2019 A UFGS 32 12 16.19 Cold-Mix Asphalt Paving N Section Number has been reinstated. Complete review and update to meet MF2016 and UFC 1-300-02. Superseding UFGS 32 12 19 BITUMINOUS BINDER AND WEARING COURSES (CENTRAL-PLANT COLD-MIX).
Nov-2020 A UFGS 32 12 16.16 Road-Mix Asphalt Paving N Superseding UFGS 32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS.
Aug-2009 A UFGS 32 12 16 Hot-Mix Asphalt (HMA) for Roads R Revised JMF requirements and Tables 7 and 8 revised; changed text to active voice
Aug-2008 A UFGS 32 12 16 Hot-Mix Asphalt (HMA) for Roads R Compliance with CSI SectionFormat
Nov-2020 A UFGS 32 12 16 Hot-Mix Asphalt (HMA) for Roads D Superseded by UFGS 32 12 16.16 ROAD-MIX ASPHALT PAVING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2018 A UFGS 32 12 15.16 Stone Matrix Asphalt (SMA) for Airfield Paving D Section is no longer active. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2012 A UFGS 32 12 15.16 Stone Matrix Asphalt (SMA) for Airfield Paving N New UFGS section
Feb-2019 A UFGS 32 12 15.16 Stone Matrix Asphalt (SMA) for Airfield Paving N Section number reinstated; Superseding UFGS 32 13 17 STONE MATRIX ASPHALT (SMA) FOR AIRFIELD PAVEMENTS. Complete review and update including section number and title changes.
Nov-2017 A UFGS 32 12 15.13 Asphalt Paving for Airfields R Complete review and update including section title change.
Nov-2015 A UFGS 32 12 15.13 Asphalt Paving for Airfields R UFGS refresh review and update.
Nov-2014 A UFGS 32 12 15.13 Asphalt Paving for Airfields C 1 Added RAP option to paragraph 2.4.2 as noted in CCR 1481.
Nov-2012 A UFGS 32 12 15.13 Asphalt Paving for Airfields N Superseding UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields. Update of the entire section.
Nov-2020 A UFGS 32 12 15.13 Asphalt Paving for Airfields R Complete review and update.
May-2022 A UFGS 32 12 15.13 Asphalt Paving for Airfields C 1 In response to CCR 10561, added appropriate references for Navy and NASA associated with paragraphs CONTRACTOR QUALITY CONTROL STAFF, CONTRACTOR QUALITY CONTROL and GENERAL QUALITY CONTROL REQUIREMENTS. In response to CCR 11001 and CCR 9916, consolidated and clarified straightedge testing for longitudinal and transverse smoothness as well as revised Profilograph Testing requirements and associated acceptance Table 2. Prohibited the use of recycled asphalt shingles (RAS) in the asphalt mixture.
May-2010 A UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields R Submittal article configuration compliance and revisions provided by USACE Transportation Center
May-2009 A UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields R Added Marshall Compaction Requirements
Apr-2008 A UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields R Revisions throughout
Nov-2012 A UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields D Superseded by UFGS 32 12 15.13 Hot-Mix Asphalt Airfield Paving for conformance with current CSI MasterFormat. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2011 A UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields R Miscellaneous updates by The Transportation Systems Center
Apr-2007 A UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields R VMA and joints
Jul-2006 A UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields R Various minor revisions
May-2017 A UFGS 32 12 13 Bituminous Tack and Prime Coats N Superseding UFGS 32 12 10; Total review and update with no title change.
May-2018 A UFGS 32 12 11 Bituminous Surface Treatment D Superseded by UFGS 32 01 13.62 ASPHALT SURFACE TREATMENT. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2008 A UFGS 32 12 11 Bituminous Surface Treatment R Compliance with CSI SectionFormat
Nov-2008 A UFGS 32 12 11 Bituminous Surface Treatment R Corrected table units
May-2017 A UFGS 32 12 10 Bituminous Tack and Prime Coats D Superseded by UFGS 32 12 13 with same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2008 A UFGS 32 12 10 Bituminous Tack and Prime Coats R Compliance with CSI SectionFormat
Oct-2006 A UFGS 32 12 10 Bituminous Tack and Prime Coats R Reconciled for lost data
Jul-2006 A UFGS 32 12 10 Bituminous Tack and Prime Coats R Added sustainable design requirements
Apr-2006 N UFGS 32 11 36.13 Lean Concrete Base Course R To conform with CSI MasterFormat, replacing without change UFGS-02712 (August 2004)
Nov-2019 N UFGS 32 11 36.13 Lean Concrete Base Course R Complete review and update to meet MF2016 and UFC 1-300-02.
Aug-2008 A UFGS 32 11 34 Portland Cement-Stabilized Base or Subbase Course R Compliance with CSI SectionFormat
May-2020 A UFGS 32 11 34 Portland Cement-Stabilized Base or Subbase Course D Superseded by UFGS 32 11 33.13 PORTLAND CEMENT-STABILIZED BASE COURSES. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2020 A UFGS 32 11 33.13 Portland Cement-Stabilized Base Courses N Superseding UFGS 32 11 34 PORTLAND CEMENT-STABILIZED BASE OR SUBBASE COURSE.
Aug-2008 N UFGS 32 11 33 Cement Stabilized [Base] [Subbase] Course at Airfields and Roads R Minor revisions throughout
Aug-2020 N UFGS 32 11 33 Cement Stabilized [Base] [Subbase] Course at Airfields and Roads D Superseded by UFGS 32 11 33.13 PORTLAND CEMENT-STABILIZED BASE COURSES Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2008 N UFGS 32 11 30 Lime Treated Subgrade [Lime Modified Soils] R Minor revisions throughout
May-2020 N UFGS 32 11 30 Lime Treated Subgrade [Lime Modified Soils] D Superseded by UFGS 32 11 13.13 LIME TREATED SUBGRADE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2009 A UFGS 32 11 29 Lime-[Stabilized] [Modified] Subgrade R Title changed from Lime-Stabilized Base Course, Subbase, or Subgrade and revisions to comply with UFC 3-250-11
Nov-2009 A UFGS 32 11 29 Lime-[Stabilized] [Modified] Subgrade R Revisions throughout including, but not limited to, Pneumatic-Tired Rollers, Submittals, Mix Design, Installation, Sampling and Testing, Field Quality Control

Pages