Unified Facilities Guide Specifications (UFGS)  Subscribe to Unified Facilities Guide Specifications (UFGS)

UFGS Master Updated February 19, 2020; Posted February 27, 2020

Unified Facilities Guide Specifications (UFGS) are a joint effort of the U.S. Army Corps of Engineers (USACE), the Naval Facilities Engineering Command (NAVFAC), the Air Force Civil Engineer Center (HQ AFCEC) and the National Aeronautics and Space Administration (NASA). UFGS are for use in specifying construction for the military services.

The Unified Facilities Guide Specifications (UFGS) are published only in electronic format and are intended to be used with SpecsIntact software. The UFGS Master uses the latest CSI MasterFormat, therefore, as of January 2012, the UFGS Working Group decided to discontinue support of MasterFormat 1995. SpecsIntact version 4.5.1 and above will support MasterFormat 2010 and will no longer support the creation of Jobs or Masters using the old MasterFormat 1995 UFGS Master. For backward compatibility, Masters or Jobs created with older versions can still be opened using the latest software versions.

As of June 2008 :Updated UFGS will be posted quarterly in February, May, August and November.

As of May 2013: The May 2013 release incorporates Automatic Paragraph Numbering. Versions of Specsintact older than 4.5.0 are not compatible with this feature. Existing jobs can be converted to the new automatic numbered format. The conversion is a one-way process. To convert, select the job or master, select process menu, choose convert Job/Master to Automatic numbering. More information about Automatic Paragraph Numbering is available on the SpecsIntact website.

For Specsintact Technical Support: 321-867-8800  |   E-mail  |   specsintact.ksc.nasa.gov

UFGS that have been unified for use by all participating agencies have a level 3 or level 4 MasterFormat™ number. UFGS that are agency-specific have a fifth level number indicating it as an agency specific specification. A specification that has a fifth level number "10" indicates USACE, a "20" indicates NAVFAC, a "30" indicates AFCEC, and a "40" indicates NASA. Preparing agencies are indicated in the UFGS header of each specification. The user should follow this order of precedence in selecting UFGS sections:

  1. Regional UFGS specific to their Agency
  2. UFGS identified as specific to their Agency
  3. Unified UFGS if one is available
  4. UFGS identified as specific to another DoD Agency (for DoD projects only)
  5. UFGS from another agency.

Points of contact and procedures for the development and maintenance of UFGS documents are prescribed in the latest edition of MIL-STD-3007.

Section templates for MasterFormat 2010 and MasterFormat 1995: These templates are provided to assist the user in creating a new section.

SpecsIntact for NMCI Users

Questions, comments, suggestions and recommended changes for guide specifications are welcome and should be submitted as a Criteria Change Request. To submit a Criteria Change Request, click on the CCR link next to the document below. If a CCR does not fit cleanly into an existing section, submit a CCR to the section most closely related to the CCR. CCRs are not appropriate when they pertain to a specific project solicitation, request for proposal or after a project award. Questions or interpretations pertaining to these documents or situation should be referred to the Contracting Officer.

Click the 'Title' or 'Date' heading to sort by ascending or descending order. Narrow the list by selecting a 'Division' option from the drop-down or view archived documents by selecting from the 'Status' drop-down and clicking 'Apply'.

These documents are available in the following formats:   Adobe Acrobat (PDF)  |   SpecsIntact (SEC) in compressed ZIP

  Indicates the UFGS has an attachment. Click the title to view the attachment under 'Related Materials'.

Titlesort descending Date View CCR
UFGS 33 51 13.00 30 Natural-Gas Metering   05-01-2010  PDF |  ZIP  CCR
UFGS 33 51 15 Natural-Gas / Liquid Petroleum Gas Distribution Pipelines   08-01-2019  PDF |  ZIP  CCR
UFGS 33 51 39 Monitoring Wells   08-01-2017  PDF |  ZIP  CCR
UFGS 33 52 10 Fuel Systems Piping (Service Station)   11-01-2018  PDF |  ZIP  CCR
UFGS 33 52 23.15 POL Service Piping Welding   11-01-2018  PDF |  ZIP  CCR
UFGS 33 52 40 Fuel Systems Piping (Non-Hydrant)   11-01-2018  PDF |  ZIP  CCR
UFGS 33 52 43.11 Aviation Fuel Mechanical Equipment   08-01-2018  PDF |  ZIP  CCR
UFGS 33 52 43.12 Aviation Fuel Pantographs   08-01-2018  PDF |  ZIP  CCR
UFGS 33 52 43.13 Aviation Fuel Piping   08-01-2018  PDF |  ZIP  CCR
UFGS 33 52 43.14 Aviation Fuel Control Valves   08-01-2018  PDF |  ZIP  CCR
UFGS 33 52 43.23 Aviation Fuel Pumps   08-01-2018  PDF |  ZIP  CCR
UFGS 33 52 43.28 Filter Separator, Aviation Fueling System   08-01-2018  PDF |  ZIP  CCR
UFGS 33 52 80 Liquid Fuels Pipeline Coating Systems   02-01-2010  PDF |  ZIP  CCR
UFGS 33 56 10 Factory-Fabricated Fuel Storage Tanks   05-01-2019  PDF |  ZIP  CCR
UFGS 33 56 19 Fuel Impermeable Liner System   05-01-2015  PDF |  ZIP  CCR
UFGS 33 56 21.17 Single Wall Aboveground Fixed Roof Steel POL Storage Tank   11-01-2018  PDF |  ZIP  CCR
UFGS 33 56 21.18 Single Wall POL Tank Undertank Interstitial Space   11-01-2018  PDF |  ZIP  CCR
UFGS 33 56 53 Pressure Vessels for Storage of Compressed Gases   04-01-2008  PDF |  ZIP  CCR
UFGS 33 57 55 Fuel Systems Components (Non-Hydrant)   11-01-2018  PDF |  ZIP  CCR
UFGS 33 60 02 Aboveground Heat Distribution System   04-01-2008  PDF |  ZIP  CCR
UFGS 33 61 13 Pre-Engineered Underground Heat Distribution System   08-01-2010  PDF |  ZIP  CCR
UFGS 33 61 13.13 Prefabricated Underground Hydronic Energy Distribution   02-01-2016  PDF |  ZIP  CCR
UFGS 33 61 13.19 Valves, Piping, and Equipment in Valve Manholes   02-01-2016  PDF |  ZIP  CCR
UFGS 33 61 14 Exterior Buried Preinsulated Water Piping   02-01-2010  PDF |  ZIP  CCR
UFGS 33 63 13 Exterior Underground Steam Distribution System   04-01-2006  PDF |  ZIP  CCR
UFGS 33 63 13.19 Concrete Trench Hydronic and Steam Energy Distribution   02-01-2016  PDF |  ZIP  CCR
UFGS 33 63 14 Exterior Buried Pumped Condensate Return   04-01-2006  PDF |  ZIP  CCR
UFGS 33 63 16 Exterior Shallow Trench Steam Distribution   07-01-2006  PDF |  ZIP  CCR
UFGS 33 63 23 Exterior Aboveground Steam Distribution   04-01-2006  PDF |  ZIP  CCR
UFGS 33 71 01 Overhead Transmission and Distribution   05-01-2019  PDF |  ZIP  CCR
UFGS 33 71 01.00 40 Overhead Transmission and Distribution   11-01-2014  PDF |  ZIP  CCR
UFGS 33 71 02 Underground Electrical Distribution   02-01-2015  PDF |  ZIP  CCR
UFGS 33 73 00.00 40 Utility Transformers   05-01-2019  PDF |  ZIP  CCR
UFGS 33 75 00.00 40 Switchgear and Protection Devices   11-01-2014  PDF |  ZIP  CCR
UFGS 33 77 19.00 40 Medium-Voltage Switch   08-01-2016  PDF |  ZIP  CCR
UFGS 33 77 36.00 40 Medium-Voltage Utility Fuses   05-01-2017  PDF |  ZIP  CCR
UFGS 33 82 00 Telecommunications Outside Plant (OSP)   04-01-2006  PDF |  ZIP  CCR
UFGS 34 11 00 Railroad Track and Accessories   04-01-2008  PDF |  ZIP  CCR
UFGS 34 11 19.00 20 Welding Crane and Railroad Rail - Thermite Method   08-01-2018  PDF |  ZIP  CCR
UFGS 34 71 13.16 Vehicle Crash Barriers   02-01-2015  PDF |  ZIP  CCR
UFGS 34 71 13.19 Crash Rated Active Vehicle Barriers and Controls   02-01-2020  PDF |  ZIP  CCR
UFGS 34 73 13 Aircraft Tiedowns   11-01-2019  PDF |  ZIP  CCR
UFGS 34 73 16 Airfield Grounding   11-01-2019  PDF |  ZIP  CCR
UFGS 35 01 41.00 10 Electromechanical Operating Machinery for Locks and Dams   11-01-2014  PDF |  ZIP  CCR
UFGS 35 01 70.13 Wire Rope for Gate Operating Devices   05-01-2014  PDF |  ZIP  CCR
UFGS 35 05 40.14 10 Hydraulic Power Systems for Civil Works Structures   11-01-2018  PDF |  ZIP  CCR
UFGS 35 05 40.17 Self-Lubricated Materials, Fabrication, Handling and Assembly   05-01-2014  PDF |  ZIP  CCR
UFGS 35 20 14 Stoplogs   04-01-2008  PDF |  ZIP  CCR
UFGS 35 20 15 FRP Composites for Low-Head Water Control Structures   08-01-2018  PDF |  ZIP  CCR
UFGS 35 20 16.33 Miter Gates   01-01-2008  PDF |  ZIP  CCR
UFGS 35 20 16.39 Sector Gates   01-01-2008  PDF |  ZIP  CCR
UFGS 35 20 16.46 Tainter Gates and Anchorages   01-01-2008  PDF |  ZIP  CCR
UFGS 35 20 16.53 Vertical Lift Gates   01-01-2008  PDF |  ZIP  CCR
UFGS 35 20 16.59 Closure Gates   01-01-2008  PDF |  ZIP  CCR
UFGS 35 20 20 Electrical Equipment for Gate Hoist   01-01-2008  PDF |  ZIP  CCR
UFGS 35 20 23 Dredging   04-01-2006  PDF |  ZIP  CCR
UFGS 35 31 19 Stone, Channel, Shoreline/Coastal Protection for Structures   01-01-2008  PDF |  ZIP  CCR
UFGS 35 31 19.20 Articulating Concrete Block Revetments   01-01-2008  PDF |  ZIP  CCR
UFGS 35 41 00 Levee Construction   11-01-2018  PDF |  ZIP  CCR
UFGS 35 42 34 Reinforced Soil Slope   01-01-2008  PDF |  ZIP  CCR
UFGS 35 45 01 Vertical Pumps, Axial-Flow and Mixed-Flow Impeller-Type   02-01-2016  PDF |  ZIP  CCR
UFGS 35 45 02.00 10 Submersible Pump, Axial-Flow and Mixed-Flow Type   02-01-2016  PDF |  ZIP  CCR
UFGS 35 45 03.00 10 Speed Reducers for Storm Water Pumps   02-01-2016  PDF |  ZIP  CCR
UFGS 35 51 13.00 20 Concrete Floating Pier for Small Craft   04-01-2006  PDF |  ZIP  CCR
UFGS 35 59 13.13 Prestressed Concrete Fender Piling   08-01-2009  PDF |  ZIP  CCR
UFGS 35 59 13.14 20 Polymeric Piles   02-01-2018  PDF |  ZIP  CCR
UFGS 35 59 13.16 Marine Fenders   05-01-2011  PDF |  ZIP  CCR
UFGS 35 59 13.19 Arch-Type Rubber Marine Fenders   04-01-2006  PDF |  ZIP  CCR
UFGS 35 73 13 Embankment for Earth and Rockfill Dams   11-01-2018  PDF |  ZIP  CCR
UFGS 40 05 13 Pipelines, Liquid Process Piping   10-01-2007  PDF |  ZIP  CCR
UFGS 40 05 13.96 Welding Process Piping   05-01-2010  PDF |  ZIP  CCR
UFGS 40 17 26.00 20 Welding Pressure Piping   04-01-2006  PDF |  ZIP  CCR
UFGS 40 17 30.00 40 Welding General Piping   05-01-2016  PDF |  ZIP  CCR
UFGS 40 18 00.00 40 Vacuum Systems Process Piping   05-01-2017  PDF |  ZIP  CCR
UFGS 40 95 00 Process Control   11-01-2019  PDF |  ZIP  CCR
UFGS 41 22 13.14 Bridge Cranes, Overhead Electric, Top Running   11-01-2019  PDF |  ZIP  CCR
UFGS 41 22 13.15 Bridge Cranes, Overhead Electric, Under Running   02-01-2020  PDF |  ZIP  CCR
UFGS 41 22 13.16 Gantry Cranes   04-01-2008  PDF |  ZIP  CCR
UFGS 41 22 13.33 Portal Crane Track Installation   05-01-2010  PDF |  ZIP  CCR
UFGS 41 22 23.19 Monorail Hoists   04-01-2008  PDF |  ZIP  CCR
UFGS 41 24 26 Hydraulic Fluid Power Systems   01-01-2008  PDF |  ZIP  CCR
UFGS 41 36 30.00 10 Ultrasonic Inspection of Plates   01-01-2008  PDF |  ZIP  CCR
UFGS 41 65 10.00 10 [Diesel] [Natural Gas] Fueled Engine Pump Drives   05-01-2009  PDF |  ZIP  CCR
UFGS 42 22 00.00 40 Process Chillers and Coolers   05-01-2017  PDF |  ZIP  CCR
UFGS 42 22 13.00 40 Centrifugal Process Chillers and Coolers   08-01-2017  PDF |  ZIP  CCR
UFGS 42 22 16.00 40 Reciprocating Process Chillers and Coolers   08-01-2017  PDF |  ZIP  CCR
UFGS 42 23 13.00 40 Process Condensers   08-01-2017  PDF |  ZIP  CCR
UFGS 43 11 00 Fans/Blowers/Pumps; Off-Gas   04-01-2008  PDF |  ZIP  CCR
UFGS 43 13 13.13 Vapor Phase Activated Carbon Adsorption Units   10-01-2007  PDF |  ZIP  CCR
UFGS 43 15 00.00 20 Low Pressure Compressed Air Piping (Non-Breathing Air Type)   04-01-2006  PDF |  ZIP  CCR
UFGS 43 21 29 Flow Measuring Equipment (Potable Water) (Sewage Treatment Plant)   04-01-2006  PDF |  ZIP  CCR
UFGS 43 31 13.13 10 Activated Carbon-Gas and Liquid Purification Filters   08-01-2018  PDF |  ZIP  CCR
UFGS 43 41 16.16 40 Vertical Atmospheric Tanks and Vessels   08-01-2017  PDF |  ZIP  CCR
UFGS 44 10 00 Air Pollution Control   10-01-2007  PDF |  ZIP  CCR
UFGS 44 13 52 Thermal (Catalytic) Oxidation Systems   02-01-2011  PDF |  ZIP  CCR
UFGS 46 07 53 Packaged Wastewater Treatment Equipment   02-01-2020  PDF |  ZIP  CCR
UFGS 46 07 53.19 Composting Toilet   02-01-2011  PDF |  ZIP  CCR
UFGS 46 20 20 Sewage Bar Screen and Mechanical Shredder   02-01-2011  PDF |  ZIP  CCR
UFGS 46 23 00 Grit Removal and Handling Equipment   02-01-2020  PDF |  ZIP  CCR
UFGS 46 24 16 Comminutors   02-01-2011  PDF |  ZIP  CCR

Pages