Unified Facilities Guide Specifications (UFGS)  Subscribe to Unified Facilities Guide Specifications (UFGS)

UFGS Master Updated August 13, 2020; Posted August 20, 2020

Unified Facilities Guide Specifications (UFGS) are a joint effort of the U.S. Army Corps of Engineers (USACE), the Naval Facilities Engineering Command (NAVFAC), the Air Force Civil Engineer Center (HQ AFCEC) and the National Aeronautics and Space Administration (NASA). UFGS are for use in specifying construction for the military services.

The Unified Facilities Guide Specifications (UFGS) are published only in electronic format and are intended to be used with SpecsIntact software. The UFGS Master uses the latest CSI MasterFormat, therefore, as of January 2012, the UFGS Working Group decided to discontinue support of MasterFormat 1995. SpecsIntact version 4.5.1 and above will support MasterFormat 2010 and will no longer support the creation of Jobs or Masters using the old MasterFormat 1995 UFGS Master. For backward compatibility, Masters or Jobs created with older versions can still be opened using the latest software versions.

As of June 2008 :Updated UFGS will be posted quarterly in February, May, August and November.

As of May 2013: The May 2013 release incorporates Automatic Paragraph Numbering. Versions of Specsintact older than 4.5.0 are not compatible with this feature. Existing jobs can be converted to the new automatic numbered format. The conversion is a one-way process. To convert, select the job or master, select process menu, choose convert Job/Master to Automatic numbering. More information about Automatic Paragraph Numbering is available on the SpecsIntact website.

For Specsintact Technical Support: 321-867-8800  |   E-mail  |   specsintact.ksc.nasa.gov

UFGS that have been unified for use by all participating agencies have a level 3 or level 4 MasterFormat™ number. UFGS that are agency-specific have a fifth level number indicating it as an agency specific specification. A specification that has a fifth level number "10" indicates USACE, a "20" indicates NAVFAC, a "30" indicates AFCEC, and a "40" indicates NASA. Preparing agencies are indicated in the UFGS header of each specification. The user should follow this order of precedence in selecting UFGS sections:

  1. Regional UFGS specific to their Agency
  2. UFGS identified as specific to their Agency
  3. Unified UFGS if one is available
  4. UFGS identified as specific to another DoD Agency (for DoD projects only)
  5. UFGS from another agency.

Points of contact and procedures for the development and maintenance of UFGS documents are prescribed in the latest edition of MIL-STD-3007.

Section templates for MasterFormat 2010 and MasterFormat 1995: These templates are provided to assist the user in creating a new section.

SpecsIntact for NMCI Users

Questions, comments, suggestions and recommended changes for guide specifications are welcome and should be submitted as a Criteria Change Request. To submit a Criteria Change Request, click on the CCR link next to the document below. If a CCR does not fit cleanly into an existing section, submit a CCR to the section most closely related to the CCR. CCRs are not appropriate when they pertain to a specific project solicitation, request for proposal or after a project award. Questions or interpretations pertaining to these documents or situation should be referred to the Contracting Officer.

Click the 'Title' or 'Date' heading to sort by ascending or descending order. Narrow the list by selecting a 'Division' option from the drop-down or view archived documents by selecting from the 'Status' drop-down and clicking 'Apply'.

These documents are available in the following formats:   Adobe Acrobat (PDF)  |   SpecsIntact (SEC) in compressed ZIP

  Indicates the UFGS has an attachment. Click the title to view the attachment under 'Related Materials'.

Titlesort descending Date View CCR
UFGS 35 59 13.14 20 Polymeric Piles   02-01-2018  PDF |  ZIP  CCR
UFGS 35 59 13.16 Marine Fenders   05-01-2011  PDF |  ZIP  CCR
UFGS 35 59 13.19 Arch-Type Rubber Marine Fenders   04-01-2006  PDF |  ZIP  CCR
UFGS 35 73 13 Embankment for Earth and Rockfill Dams   11-01-2018  PDF |  ZIP  CCR
UFGS 40 05 13 Pipelines, Liquid Process Piping   10-01-2007  PDF |  ZIP  CCR
UFGS 40 05 13.96 Welding Process Piping   05-01-2010  PDF |  ZIP  CCR
UFGS 40 17 26.00 20 Welding Pressure Piping   04-01-2006  PDF |  ZIP  CCR
UFGS 40 17 30.00 40 Welding General Piping   05-01-2016  PDF |  ZIP  CCR
UFGS 40 18 00.00 40 Vacuum Systems Process Piping   05-01-2017  PDF |  ZIP  CCR
UFGS 40 60 00 Process Control   05-01-2020  PDF |  ZIP  CCR
UFGS 41 22 13.14 Bridge Cranes, Overhead Electric, Top Running   11-01-2019  PDF |  ZIP  CCR
UFGS 41 22 13.15 Bridge Cranes, Overhead Electric, Under Running   02-01-2020  PDF |  ZIP  CCR
UFGS 41 22 13.16 Gantry Cranes   04-01-2008  PDF |  ZIP  CCR
UFGS 41 22 13.33 Portal Crane Track Installation   05-01-2010  PDF |  ZIP  CCR
UFGS 41 22 23.19 Monorail Hoists   05-01-2020  PDF |  ZIP  CCR
UFGS 41 24 26 Hydraulic Power Systems   05-01-2020  PDF |  ZIP  CCR
UFGS 41 36 30.00 10 Ultrasonic Inspection of Plates   01-01-2008  PDF |  ZIP  CCR
UFGS 41 65 10.00 10 [Diesel] [Natural Gas] Fueled Engine Pump Drives   05-01-2009  PDF |  ZIP  CCR
UFGS 42 22 00.00 40 Process Chillers and Coolers   05-01-2017  PDF |  ZIP  CCR
UFGS 42 22 13.00 40 Centrifugal Process Chillers and Coolers   08-01-2017  PDF |  ZIP  CCR
UFGS 42 22 16.00 40 Reciprocating Process Chillers and Coolers   08-01-2017  PDF |  ZIP  CCR
UFGS 42 23 13.00 40 Process Condensers   08-01-2017  PDF |  ZIP  CCR
UFGS 43 11 00.10 Off-Gas Fans, Blowers and Pumps   05-01-2020  PDF |  ZIP  CCR
UFGS 43 15 00.00 20 Low Pressure Compressed Air Piping (Non-Breathing Air Type)   04-01-2006  PDF |  ZIP  CCR
UFGS 43 21 29 Flow Measuring Equipment (Potable Water) (Sewage Treatment Plant)   04-01-2006  PDF |  ZIP  CCR
UFGS 43 31 13.13 10 Activated Carbon-Gas and Liquid Purification Filters   08-01-2018  PDF |  ZIP  CCR
UFGS 43 41 16.16 40 Vertical Atmospheric Tanks and Vessels   08-01-2017  PDF |  ZIP  CCR
UFGS 44 10 00 Air Pollution Control   10-01-2007  PDF |  ZIP  CCR
UFGS 44 13 10.13 Vapor Phase Activated Carbon Adsorption Units   05-01-2020  PDF |  ZIP  CCR
UFGS 44 13 51 Thermal Oxidation Equipment   05-01-2020  PDF |  ZIP  CCR
UFGS 44 41 00 Water Pollution Containment And Cleanup Equipment   08-01-2020  PDF |  ZIP  CCR
UFGS 46 07 53 Packaged Wastewater Treatment Equipment   02-01-2020  PDF |  ZIP  CCR
UFGS 46 07 53.19 Composting Toilet   02-01-2011  PDF |  ZIP  CCR
UFGS 46 20 20 Sewage Bar Screen and Mechanical Shredder   02-01-2011  PDF |  ZIP  CCR
UFGS 46 23 00 Grit Removal and Handling Equipment   02-01-2020  PDF |  ZIP  CCR
UFGS 46 24 16 Comminutors   02-01-2011  PDF |  ZIP  CCR
UFGS 46 25 14 Coalescing [or Vertical Tube] Oil-Water Separators   02-01-2011  PDF |  ZIP  CCR
UFGS 46 30 00 Water and Wastewater Chemical Feed Systems   08-01-2017  PDF |  ZIP  CCR
UFGS 46 30 13 Advanced Oxidation Processes (AOP)   02-01-2011  PDF |  ZIP  CCR
UFGS 46 31 11 Chlorine Gas Feed Equipment   08-01-2017  PDF |  ZIP  CCR
UFGS 46 43 21 Circular Clarifier Equipment   02-01-2020  PDF |  ZIP  CCR
UFGS 46 51 00.00 10 Air and Gas Diffusion Equipment   02-01-2011  PDF |  ZIP  CCR
UFGS 46 53 22 Trickling Filter   05-01-2018  PDF |  ZIP  CCR
UFGS 46 53 62 Continuous Loop Reactor Wastewater Treatment System   02-01-2011  PDF |  ZIP  CCR
UFGS 46 61 00 Filtration Equipment   02-01-2011  PDF |  ZIP  CCR
UFGS 46 66 56 Open-Channel Disinfection Equipment   02-01-2011  PDF |  ZIP  CCR
UFGS 46 71 16 Gravity Belt Thickeners   02-01-2011  PDF |  ZIP  CCR
UFGS 48 06 15 Turbine Oil   08-01-2020  PDF |  ZIP  CCR
UFGS 48 14 00 Solar Photovoltaic Systems   05-01-2017  PDF |  ZIP  CCR
UFGS 48 14 13.00 20 Solar Liquid Flat Plate and Evacuated Tube Collectors   05-01-2015  PDF |  ZIP  CCR
UFGS 48 15 00 Wind Generator System   05-01-2017  PDF |  ZIP  CCR
UFGS 48 16 00 Landfill Gas Systems   05-01-2017  PDF |  ZIP  CCR
UFGS Changes and Revisions   08-01-2020
UFGS Complete   08-01-2020  PDF
UFGS Forms, Graphics, and Tables   08-01-2020
UFGS Table of Contents   08-01-2020  PDF
Unified Master Reference List (UMRL)   07-01-2020  PDF

Pages