UFGS MASTER
05/19/2025
ZIP
Unified Master Reference List (UMRL)
04/01/2025
PDF
UFGS Complete
05/29/2025
PDF
UFGS Master Table of Contents
05/29/2025
PDF
UFGS Revisions and Changes
05/29/2025
PDF
UFGS Section Template (Template CCRs Only)
05/29/2025
CCR
UFGS Forms, Graphics, and Tables
05/29/2025
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
05/01/2025
ZIP
UFGS 00 01 15 List of Drawings
02/01/2024
PDF | ZIP
CCR
DIVISION 01 - GENERAL REQUIREMENTS
05/01/2025
ZIP
UFGS 01 11 00 Summary of Work
02/01/2024
View/Download |View/Download
CCR
UFGS 01 14 00 Work Restrictions
11/01/2022
View/Download |View/Download
CCR
UFGS 01 20 00 Price and Payment Procedures
11/01/2020
View/Download |View/Download
CCR
UFGS 01 30 00 Administrative Requirements
11/01/2020
View/Download |View/Download
CCR
UFGS 01 31 20 Project Technical Data Management and Visualization
05/01/2022
View/Download |View/Download
CCR
UFGS 01 31 23.13 20 Electronic Construction and Facility Support Contract Management System (eCMS)
08/01/2023
View/Download |View/Download
CCR
UFGS 01 32 01.00 10 Project Schedule
08/01/2023
View/Download |View/Download
CCR
UFGS 01 32 16.00 20 Small Project Construction Progress Schedules
08/01/2018
View/Download |View/Download
CCR
UFGS 01 32 17.00 20 Cost-Loaded Network Analysis Schedules (NAS)
05/01/2025
View/Download |View/Download
CCR
UFGS 01 32 33.00 10 Photographic Documentation
05/01/2025
View/Download |View/Download
CCR
UFGS 01 33 00 Submittal Procedures
08/01/2018
View/Download |View/Download
CCR
UFGS 01 33 16.00 10 Design Data (Design After Award)
05/01/2016
View/Download |View/Download
CCR
UFGS 01 33 23.33 Aviation Fuel System Specific Submittal Requirements
08/01/2018
View/Download |View/Download
CCR
UFGS 01 33 29 Sustainability Requirements and Reporting
02/01/2021
View/Download |View/Download
CCR
UFGS 01 35 13 Special Project Procedures
11/01/2020
View/Download |View/Download
CCR
UFGS 01 35 26 Governmental Safety Requirements
05/01/2024
View/Download |View/Download
CCR
UFGS 01 35 29.13 Health, Safety, and Emergency Response Procedures for Contaminated Sites
11/01/2015
View/Download |View/Download
CCR
UFGS 01 42 00 Sources for Reference Publications
05/01/2024
View/Download |View/Download
CCR
UFGS 01 42 15 Metric Measurements
02/01/2024
View/Download |View/Download
CCR
UFGS 01 45 00 Quality Control
08/01/2023
View/Download |View/Download
CCR
UFGS 01 45 00.15 10 Resident Management System Contractor Mode (RMS CM)
11/01/2023
View/Download |View/Download
CCR
UFGS 01 45 35 Special Inspections
05/01/2024
View/Download |View/Download
CCR
UFGS 01 50 00 Temporary Construction Facilities and Controls
11/01/2020
View/Download |View/Download
CCR
UFGS 01 57 19 Temporary Environmental Controls
08/01/2022
View/Download |View/Download
CCR
UFGS 01 58 00 Project Identification
08/01/2019
View/Download |View/Download
CCR
UFGS 01 74 19 Construction Waste Management and Disposal
02/01/2019
View/Download |View/Download
CCR
UFGS 01 78 00 Closeout Submittals
05/01/2019
View/Download |View/Download
CCR
UFGS 01 78 23 Operation and Maintenance Data
05/01/2023
View/Download |View/Download
CCR
UFGS 01 78 23.33 Operation and Maintenance Manuals for Aviation Fuel Systems
08/01/2018
View/Download |View/Download
CCR
UFGS 01 78 24.00 10 Facility Data Requirements
05/01/2023
View/Download |View/Download
CCR
UFGS 01 78 24.00 20 Facility Data Workbook (FDW)
05/01/2023
View/Download |View/Download
CCR
UFGS 01 91 00.15 Building Commissioning
05/01/2023
View/Download |View/Download
CCR
UFGS 01 91 19 Building Enclosure Commissioning
05/01/2023
View/Download |View/Download
CCR
DIVISION 02 - EXISTING CONDITIONS
05/01/2025
ZIP
UFGS 02 32 13 Subsurface Drilling and Sampling
02/01/2021
View/Download |View/Download
CCR
UFGS 02 41 00 [Demolition] [and] [Deconstruction]
08/01/2022
View/Download |View/Download
CCR
UFGS 02 42 51 Carpet Removal and Reclamation
11/01/2019
View/Download |View/Download
CCR
UFGS 02 42 91 Removal and Salvage of Historic Construction Materials
11/01/2018
View/Download |View/Download
CCR
UFGS 02 51 19 Solidification and Stabilization Decontamination
02/01/2025
View/Download |View/Download
CCR
UFGS 02 53 16.13 Remediation of Contaminated Soils by Thermal Desorption
02/01/2025
View/Download |View/Download
CCR
UFGS 02 53 16.16 In-Situ Thermal Remediation
02/01/2025
View/Download |View/Download
CCR
UFGS 02 54 19.13 Bioremediation Using Landfarming
02/01/2025
View/Download |View/Download
CCR
UFGS 02 54 19.16 Bioremediation of Soils Using Windrow Composting
02/01/2025
View/Download |View/Download
CCR
UFGS 02 54 23 Soil Washing Through Separation/Solubilization
02/01/2025
View/Download |View/Download
CCR
UFGS 02 56 13.13 Geomembrane Waste Containment
02/01/2025
View/Download |View/Download
CCR
UFGS 02 56 13.16 Clay Waste Containment
02/01/2025
View/Download |View/Download
CCR
UFGS 02 56 13.19 Geosynthetic Clay Liner Waste Containment
02/01/2025
View/Download |View/Download
CCR
UFGS 02 61 13 Excavation and Handling of Contaminated Material
02/01/2025
View/Download |View/Download
CCR
UFGS 02 61 23 Removal and Disposal of PCB Contaminated Soils
02/01/2025
View/Download |View/Download
CCR
UFGS 02 62 13.00 10 Air and Steam Stripping
08/01/2018
View/Download |View/Download
CCR
UFGS 02 62 16.13 10 Operation, Maintenance and Process Monitoring for Soil Vapor Extraction (SVE) Systems
08/01/2018
View/Download |View/Download
CCR
UFGS 02 62 16.16 10 Commissioning and Demonstration for Soil Vapor Extraction (SVE) Systems
08/01/2018
View/Download |View/Download
CCR
UFGS 02 65 00 Underground Storage Tank Removal
11/01/2022
View/Download |View/Download
CCR
UFGS 02 66 13 Select Fill and Topsoil for Landfill Cover
02/01/2025
View/Download |View/Download
CCR
UFGS 02 66 16 Test Fill
02/01/2021
View/Download | ZIP
CCR
UFGS 02 72 13.13 Point of Entry Treatment for Drinking Water
02/01/2025
View/Download |View/Download
CCR
UFGS 02 81 00 Transportation and Disposal of Hazardous Materials
11/01/2018
View/Download |View/Download
CCR
UFGS 02 82 00 Asbestos Remediation
11/01/2018
View/Download |View/Download
CCR
UFGS 02 83 00 Lead Remediation
11/01/2018
View/Download |View/Download
CCR
UFGS 02 84 16 Handling of Lighting Ballasts and Lamps Containing PCBs and Mercury
11/01/2022
View/Download |View/Download
CCR
UFGS 02 84 33 Removal and Disposal of Polychlorinated Biphenyls (PCBs)
11/01/2022
View/Download |View/Download
CCR
UFGS 02 85 00 Mold Remediation
11/01/2018
View/Download |View/Download
CCR
DIVISION 03 - CONCRETE
05/01/2025
ZIP
UFGS 03 01 00 Rehabilitation of Concrete
02/01/2018
View/Download |View/Download
CCR
UFGS 03 11 19.00 Insulating Concrete Forming
08/01/2022
View/Download |View/Download
CCR
UFGS 03 23 00 Stressed Tendon Reinforcing
05/01/2016
View/Download |View/Download
CCR
UFGS 03 30 00 Cast-In-Place Concrete
02/01/2019
View/Download |View/Download
CCR
UFGS 03 30 53 Miscellaneous Cast-In-Place Concrete
05/01/2014
View/Download |View/Download
CCR
UFGS 03 31 29 Marine Concrete with Service Life Modeling
05/01/2024
View/Download |View/Download
CCR
UFGS 03 31 30 Marine Concrete
05/01/2024
View/Download |View/Download
CCR
UFGS 03 33 00 Cast-In-Place Architectural Concrete
11/01/2009
View/Download |View/Download
CCR
UFGS 03 37 00 Preplaced-Aggregate Concrete
11/01/2009
View/Download |View/Download
CCR
UFGS 03 37 13 Shotcrete
02/01/2018
View/Download |View/Download
CCR
UFGS 03 37 23 Roller-Compacted Concrete for Mass Concrete Construction
11/01/2009
View/Download |View/Download
CCR
UFGS 03 37 29 Concrete for Concrete Cutoff Walls
11/01/2009
View/Download |View/Download
CCR
UFGS 03 41 16.08 Precast Concrete Slabs (MAX. SPAN 8 FEET O.C.)
11/01/2019
View/Download |View/Download
CCR
UFGS 03 41 33 Precast Structural Pretensioned Concrete
11/01/2016
View/Download |View/Download
CCR
UFGS 03 42 13.00 10 Plant-Precast Concrete Products for Below Grade Construction
05/01/2016
View/Download |View/Download
CCR
UFGS 03 44 00 Reinforced Autoclave Aerated Concrete Panels
02/01/2013
View/Download |View/Download
CCR
UFGS 03 45 00 Precast Architectural Concrete
05/01/2016
View/Download |View/Download
CCR
UFGS 03 45 33 Precast [Prestressed] Structural Concrete
05/01/2016
View/Download |View/Download
CCR
UFGS 03 47 13 Tilt-Up Concrete
08/01/2016
View/Download |View/Download
CCR
UFGS 03 51 13 Cementitious Wood Fiber Decks
05/01/2016
View/Download |View/Download
CCR
UFGS 03 53 14 Light Reflective Nonferrous Metallic Aggregate Floor System
08/01/2021
View/Download |View/Download
CCR
UFGS 03 62 16 Metallic Non-Shrink Grouting
08/01/2023
View/Download |View/Download
CCR
UFGS 03 70 00 Mass Concrete
02/01/2010
View/Download |View/Download
CCR
DIVISION 04 - MASONRY
05/01/2025
ZIP
UFGS 04 01 20.73 Masonry Strengthening Using FRP Bars
05/01/2025
View/Download |View/Download
CCR
UFGS 04 01 20.75 Masonry Strengthening Using Surface Applied FRP Composites
05/01/2025
View/Download |View/Download
CCR
UFGS 04 03 00 Conservation Treatment for Period Masonry
11/01/2017
View/Download |View/Download
CCR
UFGS 04 20 00 Unit Masonry
05/01/2025
View/Download |View/Download
CCR
UFGS 04 23 00 Glass Unit Masonry
11/01/2015
View/Download |View/Download
CCR
DIVISION 05 - METALS
05/01/2025
ZIP
UFGS 05 05 20 Post-Installed Concrete and Masonry Anchors
05/01/2022
View/Download |View/Download
CCR
UFGS 05 05 23.13 10 Ultrasonic Inspection of Weldments
08/01/2018
View/Download |View/Download
CCR
UFGS 05 05 23.16 Structural Welding
08/01/2018
View/Download |View/Download
CCR
UFGS 05 12 00 Structural Steel
08/01/2018
View/Download |View/Download
CCR
UFGS 05 14 00.13 Welding Structural Aluminum Framing
11/01/2019
View/Download |View/Download
CCR
UFGS 05 21 00 Steel Joist Framing
05/01/2015
View/Download |View/Download
CCR
UFGS 05 30 00 Steel Decks
05/01/2015
View/Download |View/Download
CCR
UFGS 05 40 00 Cold-Formed Metal Framing
05/01/2015
View/Download |View/Download
CCR
UFGS 05 50 13 Miscellaneous Metal Fabrications
08/01/2024
View/Download |View/Download
CCR
UFGS 05 50 14 Structural Metal Fabrications
08/01/2018
View/Download |View/Download
CCR
UFGS 05 50 15 Civil Works Fabrications
08/01/2018
View/Download |View/Download
CCR
UFGS 05 51 00 Metal Stairs
08/01/2023
View/Download |View/Download
CCR
UFGS 05 51 33 Metal Ladders
08/01/2024
View/Download |View/Download
CCR
UFGS 05 52 00 Metal Railings
08/01/2023
View/Download |View/Download
CCR
UFGS 05 59 10 Rolling Cover for Aviation Refueling Vaults
11/01/2022
View/Download |View/Download
CCR
UFGS 05 59 20 Fabrication Of Hydraulic Steel Structures
05/01/2021
View/Download |View/Download
CCR
UFGS 05 72 00 Decorative Metal Specialties
08/01/2023
View/Download |View/Download
CCR
DIVISION 06 - WOOD, PLASTICS AND COMPOSITES
05/01/2025
ZIP
UFGS 06 10 00 Rough Carpentry
08/01/2016
View/Download |View/Download
CCR
UFGS 06 13 33 Pier Timberwork
11/01/2016
View/Download |View/Download
CCR
UFGS 06 17 19 Cross-Laminated Timber
11/01/2016
View/Download |View/Download
CCR
UFGS 06 18 00 Glued-Laminated Construction
08/01/2023
View/Download |View/Download
CCR
UFGS 06 20 00 Finish Carpentry
08/01/2024
View/Download |View/Download
CCR
UFGS 06 41 16.00 10 Plastic-Laminate-Clad Architectural Cabinets
08/01/2010
View/Download |View/Download
CCR
UFGS 06 61 16 Solid Surfacing Fabrications
08/01/2020
View/Download |View/Download
CCR
UFGS 06 71 33 Fiberglass Reinforced Plastic (FRP) Ladders
08/01/2023
View/Download |View/Download
CCR
UFGS 06 73 01 Fiberglass Reinforced Plastic (FRP) Grating
08/01/2023
View/Download |View/Download
CCR
UFGS 06 82 14 Fiberglass Reinforced Plastic (FRP) Pipe and Tube Railings
08/01/2023
View/Download |View/Download
CCR
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
05/01/2025
ZIP
UFGS 07 11 13 Bituminous Dampproofing
08/01/2023
View/Download |View/Download
CCR
UFGS 07 12 00 Built-Up Bituminous Waterproofing
02/01/2016
View/Download |View/Download
CCR
UFGS 07 13 53 Elastomeric Sheet Waterproofing
02/01/2016
View/Download |View/Download
CCR
UFGS 07 14 00 Fluid-Applied Waterproofing
08/01/2023
View/Download |View/Download
CCR
UFGS 07 16 19 Metallic Oxide Waterproofing
08/01/2023
View/Download |View/Download
CCR
UFGS 07 17 00 Bentonite Waterproofing
02/01/2016
View/Download |View/Download
CCR
UFGS 07 19 00 Water Repellents
08/01/2023
View/Download |View/Download
CCR
UFGS 07 21 13 Board and Block Insulation
08/01/2023
View/Download |View/Download
CCR
UFGS 07 21 16 Mineral Fiber Blanket Insulation
08/01/2023
View/Download |View/Download
CCR
UFGS 07 21 23 Loose Fill Thermal Insulation
08/01/2023
View/Download |View/Download
CCR
UFGS 07 22 00 Roof and Deck Insulation
08/01/2023
View/Download |View/Download
CCR
UFGS 07 24 00 Exterior Insulation and Finish Systems
08/01/2023
View/Download |View/Download
CCR
UFGS 07 27 10 Building Air Barrier System
08/01/2023
View/Download |View/Download
CCR
UFGS 07 27 19.01 Self-Adhering Air Barriers
08/01/2023
View/Download |View/Download
CCR
UFGS 07 27 26 Fluid-Applied Membrane Barriers
08/01/2023
View/Download |View/Download
CCR
UFGS 07 27 36 Spray Foam Air Barriers
08/01/2023
View/Download |View/Download
CCR
UFGS 07 31 13 Asphalt Shingles
08/01/2016
View/Download |View/Download
CCR
UFGS 07 31 26 Slate Shingles
08/01/2009
View/Download |View/Download
CCR