UFGS Changes and Revisions  Subscribe to UFGS Changes and Revisions

Related Materials: Policy on UFGS Changes and Revisions

Below is a listing of the Revisions and Changes made to UFGS Sections for each quarterly release.

To view a list for a specific UFGS Release, select the UFGS release date from the 'Release' drop-down and click 'Apply'.

To view a list of all the revisions and changes made to a specific UFGS Section, select 'Any' from the "Release' drop down, type the Section number into the Search bar and select the Section to view, then click 'Apply'.

After clicking 'Apply', you can PRINT REPORT, which will include the nature of the change/revision.

To view the complete detailed history of all the revisions and changes made to a UFGS Section, click on the Section title.

KEY PREPARING ACTIVITY (PA) A Army N Navy F Air Force S NASA
ACTION N New R Revision C Change D Deletion
Release PA UFGS Sectionsort descending Action Change # Nature of Change or Revision
Feb-2017 S UFGS 01 75 00.00 40 Starting and Adjusting D This Section has been retired / Action Item from the Fall 2016 Specification DWG Meeting. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2015 S UFGS 01 75 00.00 40 Starting and Adjusting R NASA reclassified this as fifth level; renumbered May 2012 version of UFGS 01 75 00 with same title; incorporated Non-Technical CCR 4149 in Subpart 1.2.1.
Oct-2006 S UFGS 01 75 00.00 40 Starting and Adjusting D Superseded; Renumbered as UFGS 01 75 00 with no title change. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Jan-2008 N UFGS 01 77 00.00 20 Closeout Procedures D Superseded by UFGS 01 78 00 Closeout Submittals Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Jul-2006 N UFGS 01 77 00.00 20 Closeout Procedures R Added sustainable design requirements
Nov-2017 A UFGS 01 78 00 Closeout Submittals C 3 Incorporated administrative changes changes in response to CCR 5943.
May-2010 A UFGS 01 78 00 Closeout Submittals R Submittal article configuration compliance and add Navy tailor tags for final cleaning
May-2009 A UFGS 01 78 00 Closeout Submittals R Clarified CADD file format
Jan-2008 A UFGS 01 78 00 Closeout Submittals N Superseding UFGS 01 77 00.00 20 Closeout Procedures, UFGS 01 78 00.00 40 Closeout Submittals and 01 78 02.00 10 Closeout Submittals
Aug-2015 A UFGS 01 78 00 Closeout Submittals C 2 Adjusted Operation and Maintenance Manual requirements. Deleted Preventive Maintenance and list of installed equipment requirements.
Aug-2011 A UFGS 01 78 00 Closeout Submittals R Added NAVFAC Sustainable & Energy Data Record Card (tailored)
May-2015 A UFGS 01 78 00 Closeout Submittals C 1 Incorporates multiple approved CCRs.
Nov-2018 A UFGS 01 78 00 Closeout Submittals C 4 Deleted reference to NFAS Clause. Added Sustainable Materials certification reporting requirements.
Feb-2019 A UFGS 01 78 00 Closeout Submittals C 5 Added submittal item to paragraph 1.7.1 in response to CCR 7121.
May-2019 A UFGS 01 78 00 Closeout Submittals R Complete review and update.
Aug-2021 A UFGS 01 78 00 Closeout Submittals C 1 Added Note to Submittal Article with instructions for Navy Design-Build projects. Deleted note and bracketed selections for Army only in response to CCR 8454.
Jan-2008 S UFGS 01 78 00.00 40 Closeout Submittals D Superseded by UFGS 01 78 00 Closeout Submittals (Preparing Activity USACE) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Jan-2008 A UFGS 01 78 02.00 10 Closeout Submittals D Superseded by UFGS 01 78 00 Closeout Submittals Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 N UFGS 01 78 23 Operation and Maintenance Data R Revised throughout. Coordinated thoroughly with UFGS 01 78 24.00 20 Facility eOMSI and UFGS 01 78 00 Closeout Submittals. Updated training requirements and O&M Manual electronic format.
Feb-2015 N UFGS 01 78 23 Operation and Maintenance Data C 3 Added Safety Hazards, Operating Log, Extended Warranty and Field Test Reports to O&M DATA PACKAGES. Coordinated with UFGS 01 78 24.00 20 Facility eOMSI .
Aug-2014 N UFGS 01 78 23 Operation and Maintenance Data C 2 Added editor's note to coordinate with UFGS 01 78 24.00 20 FACILITY eOMSI for Navy projects.
Aug-2012 N UFGS 01 78 23 Operation and Maintenance Data C 1 Modified subparts 1.2, 1.2.2, 1.2.3, 1.2.4 and 1.4-g
Jul-2006 N UFGS 01 78 23 Operation and Maintenance Data R Added sustainable design requirements
Nov-2020 N UFGS 01 78 23 Operation and Maintenance Data C 1 In opening note, incorporated Navy thresholds, from cancelled Navy ECB 2014-01, that require use of UFGS 01 78 24.00 20 FACILITY eOMSI
Aug-2021 N UFGS 01 78 23 Operation and Maintenance Data C 2 Added "Marine Corps Installations" to General Note.
May-2023 N UFGS 01 78 23 Operation and Maintenance Data R Revised throughout to unify Army and Navy requirements of Operation and Maintenance Manuals that were previously in this Section and in UFGS-01 78 24.00 10 and UFGS-01 78 24.00 20. Incorporated industry standards for the Operation and Maintenance Manual organization.
Feb-2010 A UFGS 01 78 23.33 Operation and Maintenance Manuals for Aviation Fuel Systems N New section
Aug-2018 A UFGS 01 78 23.33 Operation and Maintenance Manuals for Aviation Fuel Systems R Complete review and update.
Feb-2021 A UFGS 01 78 23.33 Operation and Maintenance Manuals for Aviation Fuel Systems C 1 Deleted editing note in paragraph 2.1.2, corrected formatting issues in paragraph 2.2, and updated editing note in paragraph 3.3.6 in response to CCR 8929.
May-2017 A UFGS 01 78 24.00 10 Facility Data Requirements R Total review and update. Section title changed from Operations and Maintenance Facility Data Requirements
May-2016 A UFGS 01 78 24.00 10 Facility Data Requirements N New UFGS for maintenance and turnover of electronic Facility Data for use by Army O&M personnel and systems of record
May-2018 A UFGS 01 78 24.00 10 Facility Data Requirements R Complete review and update to incorporate feedback received from previous project.
Nov-2021 A UFGS 01 78 24.00 10 Facility Data Requirements C 1 Incorporated CCR 10987 and corrected formatting issues.
May-2023 A UFGS 01 78 24.00 10 Facility Data Requirements R Non-technical revision to update the Target Refresh Date.
Feb-2015 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) R Deleted eOMSI manual for Primary Systems; incorporated requirements into other manuals. Coordinated FACILITY INFORMATION in this section with Section 01 78 23. Updated Record Drawing.
Nov-2014 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) C 1 Clarified how to download eOMSI Facility Data Workbook, added reference to Section 01 32 17.00 20, and in 2.3, item e, added Asset number provided by Govt.
Aug-2014 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) R Added reference note to newly published ECB; changed validation to verification, and deleted manuals from verification process.
May-2014 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) R Revised "eOMSI documents" to "eOMSI Manual", revised "eOMSI Facility data" to "eOMSI Facility Data Workbook" and revised throughout to coordinate requirements.
Nov-2013 S UFGS 01 78 24.00 20 Facility Data Workbook (FDW) C 1 Revised note before part 1.
Aug-2012 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) R Modified subparts 1.2.2 - 1.2.4, 1.2.8, 1.4.2, 1.8.1, 1.9.3, 2.1.1.1 - 2.1.2.4
Aug-2015 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) C 1 Changes coordinated with section 01 78 23 revision. Moved training and O&M Manual format to 01 78 23. Added resolutions in event of discrepancies in provided FDW, and unsuccessful Field Verification.
Nov-2011 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) N New UFGS section; superseding NAVFAC Design Build section 01 78 24.05 20 dated Nov 2010
Nov-2020 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) C 2 In opening Note, incorporated Navy thresholds, from cancelled Navy ECB 2014-01, that require use of UFGS 01 78 24.00 20, and updated Facility Data Workbook.
Aug-2021 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) C 3 In response to CCR 8939, added bracketed option for section UFGS 01 32 16.00 20 in Pre-Construction/Post-Award Kickoff Meeting paragraph. Added "Marine Corps Installations" to General Note and updated Notes for the Facility Data Workbook; modified Notes and paragraphs to have either brackets or tailoring, not both.
May-2023 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) R Removed Operation and Maintenance Manual requirements throughout, this content has been incorporated into UFGS 01 78 23. Only Facility Data Workbook requirements remain in this section. Section Title changed from FACILITY ELECTRONIC OPERATION AND MAINTENANCE SUPPORT INFORMATION (eOMSI) to FACILITY DATA WORKBOOK (FDW).
Nov-2023 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) C 1 In response to CCR 13686, added "eOMSI" to the Definitions paragraph (1.1)
Feb-2018 S UFGS 01 83 00.07 40 Reliability Centered Acceptance for Facility Shells R Tri-Annual Database Maintenance (TADM) completed.
Feb-2015 S UFGS 01 83 00.07 40 Reliability Centered Acceptance for Facility Shells C 1 Consist of imperative language, spell check, QC reports, and formatting review.
Feb-2010 S UFGS 01 83 00.07 40 Reliability Centered Acceptance for Facility Shells N New section
Feb-2012 S UFGS 01 83 00.07 40 Reliability Centered Acceptance for Facility Shells R Tri-Annual Database Maintenance - Subpart 1.3 SUBMITTALS, minor revision
Feb-2018 S UFGS 01 83 13.07 40 Reliability Centered Acceptance for Superstructure Performance Requirements R Tri-Annual Database Maintenance (TADM) completed
Feb-2015 S UFGS 01 83 13.07 40 Reliability Centered Acceptance for Superstructure Performance Requirements C 1 Consist of imperative language, spell check, QC reports, and formatting review.
Feb-2010 S UFGS 01 83 13.07 40 Reliability Centered Acceptance for Superstructure Performance Requirements N New section
Feb-2012 S UFGS 01 83 13.07 40 Reliability Centered Acceptance for Superstructure Performance Requirements R Tri-Annual Database Maintenance - Subpart 1.3 SUBMITTALS, minor revision
Feb-2018 S UFGS 01 86 12.07 40 Reliability Centered Acceptance for Mechanical Systems R Tri-Annual Database Maintenance (TADM) completed
Feb-2015 S UFGS 01 86 12.07 40 Reliability Centered Acceptance for Mechanical Systems C 1 Consist of imperative language, spell check, QC reports, and formatting review.
Feb-2010 S UFGS 01 86 12.07 40 Reliability Centered Acceptance for Mechanical Systems N New section
Feb-2012 S UFGS 01 86 12.07 40 Reliability Centered Acceptance for Mechanical Systems R Tri-Annual Database Maintenance - Subpart 1.3 SUBMITTALS, minor revision
Feb-2018 S UFGS 01 86 26.07 40 Reliability Centered Acceptance for Electrical Systems R Tri-Annual Database Maintenance (TADM) completed
Feb-2015 S UFGS 01 86 26.07 40 Reliability Centered Acceptance for Electrical Systems C 1 Consist of imperative language, spell check, QC reports, and formatting review.
Feb-2010 S UFGS 01 86 26.07 40 Reliability Centered Acceptance for Electrical Systems N New section
Feb-2012 S UFGS 01 86 26.07 40 Reliability Centered Acceptance for Electrical Systems R Tri-Annual Database Maintenance -Subpart 1.3 SUBMITTALS, minor revision
Nov-2006 N UFGS 01 91 00 Commissioning D INTERIM RELEASE: Temporarily removed from master while revision is completed. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Jul-2006 N UFGS 01 91 00 Commissioning N New section
Aug-2016 S UFGS 01 91 00.00 40 Commissioning D Replaced by UFGS Section 01 91 00.15 Total Building Commissioning (Preparing Activity: USACE). Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Nov-2014 S UFGS 01 91 00.00 40 Commissioning C 1 Edited PART 1 GENERAL and deleted the mention of Section 01 35 40.00 20; added the listing of Section 01 57 19.00 20 Temporary Environment Controls, and realigned the item lettering.
Nov-2012 S UFGS 01 91 00.00 40 Commissioning N New (for NASA Only)
May-2019 A UFGS 01 91 00.15 10 Total Building Commissioning N This UFGS is for Army and Air Force use only; superseding UFGS 01 91 00.15 TOTAL BUILDING COMMISSIONING for Army and Air Force requirements only. Note: 01 91 00.15 is now for Navy use only, USACE remains the Preparing Activity [until 05-2020].
May-2020 A UFGS 01 91 00.15 10 Total Building Commissioning C 1 Updated reference publications in response to CCR 8209.
Aug-2020 A UFGS 01 91 00.15 10 Total Building Commissioning C 2 Updated commissioning certification in paragraph 1.8.1 in response to CCR 8404.
May-2022 A UFGS 01 91 00.15 10 Total Building Commissioning C 3 Updated qualifications for electrical technical commissioning specialist in response to CCRs 9054, 9096, 9741, 9970, 10182, and 10471. Updated burn-in duration for lamps in response to CCR 9218. Updated paragraph "Design Review" in response to CCRs 9220, 9222, and 9237. Updated and changed paragraph "Acceptance" to "Equipment and Systems Deficiencies Check" in response to CCR 9223.
May-2023 A UFGS 01 91 00.15 10 Total Building Commissioning D Section Archived; 01 91 00.15 10 has been superseded by Unified Section UFGS-01 91 00.15 BUILDING COMMISSIONING Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2021 N UFGS 01 91 00.15 20 Total Building Commissioning N Navy-only Commissioning Section superseding UFGS-01 91 00.15 TOTAL BUILDING COMMISSIONING.
May-2021 N UFGS 01 91 00.15 20 Total Building Commissioning C 1 Changes made to align with NAVFAC policy, and corrections of errors and omissions.
May-2023 N UFGS 01 91 00.15 20 Total Building Commissioning D Superseded by unified UFGS-01 91 00.15 BUILDING COMMISSIONING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2017 A UFGS 01 91 00.15 Building Commissioning C 2 Updated to coordinate archiving of Navy Section 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC to meet the requirement of 10 USC 2867 to adopt a "Department-wide, Open Protocol, Energy Monitoring and Utility Control System Specification" for use in Military construction and military family housing activity.
Feb-2017 A UFGS 01 91 00.15 Building Commissioning C 1 In response to CCR 5173, added two "S" submittals in SD-11.
May-2016 A UFGS 01 91 00.15 Building Commissioning N Superseding UFGS 23 08 00.00 10 COMMISSIONING OF HVAC SYSTEMS; Total Building Commissioning requirements for new construction and major renovations.
Aug-2018 A UFGS 01 91 00.15 Building Commissioning C 3 Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures.
Feb-2019 A UFGS 01 91 00.15 Building Commissioning R Complete review and update.
May-2020 N UFGS 01 91 00.15 Building Commissioning C 1 Preparing Activity changed to NAVFAC as this section has been for Navy-use only since 05-2019; In response to the following: CCR 6881, paragraph Project Schedule (1.6.2) is not appropriate for use on Navy projects and was removed; and CCR 8403, in paragraph Lead Commissioning Specialist (1.8.1) , "ASHRAE Commissioning Process Management Professional (CPMP) was changed to "ASHRAE Building Commissioning Professional (BCxP)"
Feb-2021 N UFGS 01 91 00.15 Building Commissioning D Superseded by UFGS-01 91 00.15 20 TOTAL BUILDING COMMISSIONING Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2023 N UFGS 01 91 00.15 Building Commissioning N Section number has been reinstated with the unification of Army and Navy Commissioning Sections. This new version supersedes UFGS-01 91 00.15 10 and UFGS-01 91 00.15 20 TOTAL BUILDING COMMISSIONING. Title has been changed to BUILDING COMMISSIONING.
Aug-2023 N UFGS 01 91 00.15 Building Commissioning C 1 Clarified the language in COMMISSIONING FIRM paragraph (1.11)
Nov-2023 N UFGS 01 91 00.15 Building Commissioning C 2 In response to CCR 13595, moved language related to warranty period requirements from PROJECT SCHEDULE paragraph (1.8) to CONSTRUCTION PHASE COMMISSIONING PLANS paragraph (3.7); added language for Air Force usage.
May-2023 A UFGS 01 91 19 Building Enclosure Commissioning N New UFGS section superseding UFGS 07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS.
May-2010 A UFGS 02 01 50 Operation, Maintenance and Process Monitoring for Soil Vapor Extraction (SVE) Systems R CSI SectionFormat and submittal article configuration compliance
Aug-2018 A UFGS 02 01 50 Operation, Maintenance and Process Monitoring for Soil Vapor Extraction (SVE) Systems D Superseded by UFGS 02 62 16.13 10 OPERATION, MAINTENANCE AND PROCESS MONITORING FOR SOIL VAPOR EXTRACTION (SVE) SYSTEMS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2010 A UFGS 02 32 00 Subsurface Drilling, Sampling, and Testing R CSI SectionFormat and submittal article configuration compliance
Feb-2021 A UFGS 02 32 00 Subsurface Drilling, Sampling, and Testing D Superseded by UFGS 02 32 13 SUBSURFACE DRILLING AND SAMPLING without revision to comply with MF 2011 in response to CCR 1924. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Feb-2021 A UFGS 02 32 13 Subsurface Drilling and Sampling N Superseding UFGS 02 32 00 SUBSURFACE DRILLING, SAMPLING, AND TESTING without revision to comply with MF 2011 in response to CCR 1924. Nontechnical number and title change.
May-2010 A UFGS 02 35 27 Soil-Bentonite (S-B) Slurry Trench R CSI SectionFormat and submittal article configuration compliance
Feb-2021 A UFGS 02 35 27 Soil-Bentonite (S-B) Slurry Trench D Superseded by UFGS 31 56 13.13 SOIL-BENTONITE SLURRY WALLS without revision to comply with MF 2011 in response to CCR 1925. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
May-2010 A UFGS 02 41 00 [Demolition] [and] [Deconstruction] R CSI SectionFormat and submittal article configuration compliance
Aug-2014 A UFGS 02 41 00 [Demolition] [and] [Deconstruction] C 1 Added FAA requirements as noted in CCR 857
Oct-2006 A UFGS 02 41 00 [Demolition] [and] [Deconstruction] R Combined adding NASA requirements
Jul-2006 A UFGS 02 41 00 [Demolition] [and] [Deconstruction] R Title changed from DEMOLITION; Added sustainable design requirements
Feb-2019 A UFGS 02 41 00 [Demolition] [and] [Deconstruction] C 2 Coordinated the requirements for demolition and deconstruction activities with UFGS 01 74 19 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL.
Aug-2022 A UFGS 02 41 00 [Demolition] [and] [Deconstruction] R Complete review and update.
Jan-2007 S UFGS 02 41 00.00 40 Demolition D Superseded by UFGS 02 41 00 [Demolition][ and ][Deconstruction] (Preparing Activity: Army) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.

Pages