Unified Facilities Criteria (UFC)  Subscribe to Unified Facilities Criteria (UFC)

UFC documents provide planning, design, construction, sustainment, restoration, and modernization criteria, and apply to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with DoD Directive 4270.5 (Military Construction) and USD(AT&L) Memorandum  dated 29 May 2002. UFC are distributed only in electronic media and are effective upon issuance. 

The United States Army Corps of Engineers (HQUSACE), Naval Facilities Engineering Systems Command (NAVFAC), and the Air Force Civil Engineer Center (AFCEC) are responsible for administration of the UFC system. Points of contact and procedures for the development and maintenance UFC documents are prescribed in the latest edition of MIL-STD-3007.

UFCs that have been unified for use by all participating agencies have no alphabetical letter at the end of the document number. UFCs that are agency-specific have an alphabetical letter (or letters) at the end of the document. A document that has a letter "A" indicates USACE, an "N" indicates NAVFAC and an "F" indicates AFCEC. A combination of two letters indicates that the document is used by two agencies.

Facilities Criteria (FC) DESIGNATION

The "Facilities Criteria (FC)" designation has been adopted for criteria that are not applicable to all DoD Components. This is specific to facility-type documents only, for example, FC 4-721-10N "Navy and Marine Corps Unaccompanied Housing". Facilities Criteria (FC) provide functional requirements (i.e., defined by users and operational needs of a particular facility type). Differences in functional requirements between DoD Components may exist due to differences in policies and operational needs. FC are applicable only to the DoD Component(s) indicated in the title, and are intended for use with unified technical requirements published in DoD Unified Facilities Criteria (UFC).

See the DOD Engineering Criteria Status Report  for the list of UFCs that were formerly Agency-specific documents.

UFC Template in MS Word   (05-2021)

Questions, comments, suggestions and recommended changes for these documents are welcome and should be submitted as a Criteria Change Request (CCR). To submit a Criteria Change Request, click on the CCR link next to the document below. CCRs are not appropriate when they pertain to a specific project solicitation, request for proposal or after a project award. Questions or interpretations pertaining to these documents or situation should be referred to the Contracting Officer.

Click the 'Title', 'Date' or 'Change Date' heading to sort by ascending or descending order. Narrow the list by selecting a 'Series' option from the dropdown or view archived or inactive documents by selecting from the 'Status' dropdown and clicking 'Apply'.

These documents are available in the following format:   Adobe Acrobat (PDF)

  Indicates the UFC has an attachment. Click the title to view the attachment under 'Related Materials'.

Titlesort descending Date Change Date View CCR
UFC 4-023-03 Design of Buildings to Resist Progressive Collapse, with Change 3   07-14-2009 11-01-2016  PDF  CCR
UFC 4-023-07 Design to Resist Direct Fire Weapons Effects, with Change 1   07-07-2008 02-01-2017  PDF  CCR
UFC 4-023-10 Safe Havens   06-01-2016  PDF  CCR
UFC 4-024-01 Security Engineering: Procedures for Designing Airborne Chemical, Biological, and Radiological Protection for Buildings   06-10-2008  PDF  CCR
UFC 4-025-01 Security Engineering: Waterfront Security   11-01-2012  PDF  CCR
UFC 4-026-01 Design to Resist Forced Entry   03-04-2020  PDF  CCR
UFC 4-121-10N Design: Aircraft Fixed Point Utility Systems   01-16-2004  PDF  CCR
UFC 4-133-01 Air Traffic Control and Air Operations Facilities, with Change 2   04-19-2016 06-01-2019  PDF  CCR
UFC 4-141-04 Emergency Operations Center Planning and Design, with Change 1   07-15-2008 09-01-2008  PDF  CCR
UFC 4-141-10N Design: Aviation Operation and Support Facilities   01-16-2004  PDF  CCR
UFC 4-150-02 Dockside Utilities for Ship Service   11-12-2020  PDF  CCR
UFC 4-150-06 Military Harbors and Coastal Facilities, with Change 1   12-12-2001 10-19-2010  PDF  CCR
UFC 4-150-07 Maintenance and Operation: Maintenance of Waterfront Facilities, with Change 1   06-19-2001 09-01-2012  PDF  CCR
UFC 4-150-08 Mooring Hardware Inspection   10-28-2020  PDF  CCR
UFC 4-150-09 Permanent Anchored Moorings Operations and Maintenance   02-27-2019  PDF  CCR
UFC 4-151-10 General Criteria for Waterfront Construction, with Change 1   09-10-2001 09-01-2012  PDF  CCR
UFC 4-152-01 Design: Piers and Wharves   01-24-2017  PDF  CCR
UFC 4-152-07 Design: Small Craft Berthing Facilities; with Change 1   07-14-2009 09-01-2012  PDF  CCR
UFC 4-159-01N Design: Hyperbaric Facilities   01-16-2004  PDF  CCR
UFC 4-159-03 Moorings   03-09-2020  PDF  CCR
UFC 4-171-01N Design: Aviation Training Facilities   01-16-2004  PDF  CCR
UFC 4-179-01 Design: Navy Firefighting School Facilities   01-16-2004  PDF  CCR
UFC 4-179-02 Small Arms Ranges   03-05-2020  PDF  CCR
UFC 4-211-01 Aircraft Maintenance Hangars, with Change 3   04-13-2017 04-20-2021  PDF  CCR
UFC 4-211-02 Aircraft Corrosion Control and Paint Facilities   12-01-2012  PDF  CCR
UFC 4-212-01N Navy Engine Test Cells, with Changes 1-4   07-27-2006 09-01-2008  PDF  CCR
UFC 4-213-10 Graving Dry Docks   05-18-2020  PDF  CCR
UFC 4-214-03 Central Vehicle Wash Facilities   03-17-2018  PDF  CCR
UFC 4-215-01 Armories and Arms Rooms   12-01-2014  PDF  CCR
UFC 4-310-03 DoD Fuels Laboratory Standards   08-12-2020  PDF
UFC 4-390-01 O&M: Unmanned Pressure Test Facilities Safety Certification Manual   07-23-2003  PDF  CCR
UFC 4-420-01 Ammunition and Explosives Storage Magazines   05-01-2015  PDF  CCR
UFC 4-440-01 Warehouses and Storage Facilities, with Change 1   10-01-2014 04-01-2019  PDF  CCR
UFC 4-510-01 Design: Military Medical Facilities with Change 2   05-30-2019 12-04-2019  PDF  CCR
UFC 4-610-01 Administrative Facilities, with Change 1   01-05-2021 04-30-2021  PDF  CCR
UFC 4-711-01 Family Housing   08-10-2018  PDF  CCR
UFC 4-720-01 Lodging Facilities   02-13-2012  PDF  CCR
UFC 4-730-01 Family Service Centers, with Change 1   04-07-2006 06-20-2006  PDF  CCR
UFC 4-730-10 Fire Stations, with Change 1   05-08-2019 06-11-2021  PDF  CCR
UFC 4-740-01NF Design: Bowling Centers   04-16-2004  PDF  CCR
UFC 4-740-02 Fitness Centers, with Change 1   02-03-2019 05-30-2019  PDF  CCR
UFC 4-740-03 Design: Navy and Marine Corps Outdoor Adventure Centers and Rental Centers   11-01-2002  PDF  CCR
UFC 4-740-06 Youth Centers   01-12-2006  PDF  CCR
UFC 4-740-14 Design: Child Development Centers (USACE and Air Force only)   08-01-2002  PDF  CCR
UFC 4-740-15 Continuous Child Care Facilities   04-14-2011  PDF  CCR
UFC 4-740-16 Design: Military Recreation Centers   05-25-2005  PDF  CCR
UFC 4-740-20 Libraries   05-01-2006  PDF  CCR
UFC 4-750-01NF Design: Golf Clubhouses   04-16-2004  PDF  CCR
UFC 4-750-02N Design: Outdoor Sports and Recreational Facilities   12-04-2003  PDF  CCR
UFC 4-750-07 Recreational Aquatic Facilities   04-20-2020  PDF  CCR
UFC 4-826-10 Design: Refrigeration Systems for Cold Storage   07-10-2002  PDF  CCR
UFC 4-860-01FA Railroad Design and Rehabilitation   01-16-2004  PDF  CCR
UFC 4-860-03 Railroad Track Maintenance and Safety Standards    02-13-2008  PDF  CCR

Pages