This page contains document links to Construction Criteria Base

RESOURCE PAGE

Energy Codes and Standards

by Martha G. VanGeem
Construction Technology Laboratories, Inc. (CTL)

Last updated: 06-11-2010

Introduction

Energy codes provide minimum building requirements that are cost-effective in saving energy. The energy saved is a cost savings to the building owner through lower monthly utility bills, and smaller and thus less expensive HVAC equipment. More than 2/3rds of the electricity and 1/3rd of the total energy in the U.S. are used to heat, cool, and operate buildings. This means that implementing and enforcing energy codes will result in fewer power plants and natural resources being used to provide electricity and natural gas. It also means fewer emissions to the atmosphere. Emissions have been linked to smog, acid rain, and global warming. In the U.S. most buildings are constructed to meet minimum energy code requirements; therefore energy codes contribute to sustainability by saving energy and protecting the environment.

Energy codes are effective in reducing per capita energy usage (energy use per person). The per capita energy use in California has remained steady due to its active use and enforcement of energy codes for buildings, while energy use in the rest of the U.S. has increased.

Total Electricity Use, per capita, 1960-2000 graph.  Between 1960 and 1973 the US increased from 4,000kwh to just above 8,000kwh. In 1973 the energy usage decreased to 8,000kwh. From there usage increased to almost 10,000kwh and then decreased slightly. Then usage increases to 11,000kwh in 1991, dipped slightly and then rose to 12,000kwh in 2002. In 1960 California used 4,000kwh and increased to 7,000kwh in 1973 and has remained steady through 2002.

Fig. 1. Total Electricity Use, per capita, 1960-2001 (estimated for California for 2000 and 2001)
(Courtesy of Art Rosenfeld)

Description

A. Commonly Used Energy Codes

The U.S. Energy Conservation and Production Act (ECPA) requires that each state certify that it has a commercial building code that meets or exceeds ANSI/ASHRAE/IESNA Standard 90.1-1999. In this sense, "commercial" means all buildings that are not low-rise residential (three stories or less above grade). This includes office, industrial, warehouse, school, religious, dormitories, and high-rise residential buildings. The process is administered by the Department of Energy. ASHRAE 90.1 is the most commonly used energy code for commercial and other non-residential buildings. The Model Energy Code (MEC), now the International Energy Conservation Code (IECC), is the most commonly used residential energy code by states. The IECC also has a commercial section that allows the use of ASHRAE 90.1 for compliance. The International Residential Code (IRC) is also used by some states. The NFPA has commercial and residential energy codes based on ASHRAE Standards 90.1 and 90.2 (low-rise residential). The status of energy codes by states is available from the Building Codes Assistance Project (BCAP). Some states, such as Florida and California, have independently developed and adopted their own energy codes. Some states and jurisdictions do not yet have energy codes despite the federal requirement.

Table 1. Energy Codes in Order of Frequency of Adoption by States

Commercial¹Residential
ASHRAE 90.1IECC (MEC)
IECC²IRC
NFPA 5000³NFPA 5000³
 ASHRAE 90.2
¹Commercial codes often include high-rise residential; see individual codes for definitions.
²The IECC allows the use of ASHRAE 90.1.
³NFPA 5000 is based on ASHRAE 90.1 and 90.2.

Table 2. Residential Energy Code Adoption – Autumn 2004

MEC Version or Equivalent State CodeStates Adopted or Adopting
2003 IECC, IRC10 States (AR, CT, KS, MD, NE, NM, PA, RI, PA, VT)
2000 IECC, IRC or equivalent state code adopted or under review or in rulemaking for statewide adoption/equivalence18 States and DC (AL, CA, DC, DE, FL, GA, ID, KY, NC, NH, NY, OH, OR, SC, TX, VA, WA, WI, WV)
1998 IECC1 State (OK)
95 MEC, Mandatory statewide adoption/equivalence6 States(AK, HI*, MA, MN, NJ, VT)
95 MEC, Partial adoption/equivalence1 State (LA)
93 MEC, Mandatory statewide adoption/equivalence1 State (ND*)
92 MEC, Mandatory statewide adoption/equivalence3 States (IA, IN, TN)
No statewide residential code or residential code is not EPAct compliant10 States (AZ*, CO*, IL*, ME, MI, MO, MS*, NV*, SD, WY*)
*Code implementation depends upon the voluntary adoption by local jurisdictions.
(Source: Building Codes Assistance Project)

Table 3. Commercial Energy Code Adoption – Autumn 2004

ASHRAE/IESNA Standard or Equivalent State CodeStates Adopted or Adopting
2003 IECC/ASHRAE 90.1-200113 States (AR, CT, FL, GA, KS, ME, MT, NM, NE, SC, UT, PA, RI)
ASHRAE/IESNA 90.1-1999, Statewide or equivalent state code adoption or in adoption process21 States and DC (CA, DC, DE, ID, IL, KY, LA, MA, MD, MI, NC, NH, NJ, NY, OH, OR, TX, VA, WA, WI, WV)
ASHRAE/IESNA 90.1-1989, Mandatory statewide adoption/equivalence5 States (HI, IA, MN, ND*, OK)
No commercial code or commercial code is not EPAct compliant10 States (AK, AL, AZ*, CO*, MO*, MS, NV, SD, TN*, WY*)
*Code implementation depends upon the voluntary adoption of the code by local jurisdictions.
(Source: Building Codes Assistance Projects)

New federal commercial and multi-family high-rise residential buildings must meet standards in 10 CFR 434, based on the ANSI/ASHRAE/IESNA Standard 90.1-1989. The U.S. Department of Navy (DON) and Department of Defense (DOD) use ANSI/ASHRAE/IESNA 90.1-1999 rather than 10 CFR 434. Government low-rise residential energy standards generally comply with ENERGY STAR. The U.S. Department of Energy's Federal Energy Management Program (FEMP) oversees the efforts to reduce energy and impacts to the environment at federal sites.

Modifications to existing buildings often need to meet new building requirements or ANSI/ASHRAE/IESNA Standard 100-1995 – Energy Conservation in Existing Buildings. A common method of reporting energy performance for existing and new buildings is described in ANSI/ASHRAE Standard 105-1984 (RA 99) –Standard Methods of Measuring and Expressing Building Energy Performance.

B. Scope of Energy Codes

Energy codes generally dictate requirements for the building's envelope, mechanical, and lighting (nonresidential only) requirements. Energy codes must be easy to understand for architects and builders to use and code officials to enforce. For this reason codes cannot incorporate all good design practices and should not be confused with good practice. For instance, significant energy can be saved by considering building orientation, limiting infiltration, planting trees, and using passive solar design strategies. Yet these are not mandated in most energy codes at this time. Also, if durability of building materials were considered, energy could be saved in the manufacturing and installation of replacement materials throughout the life of the building. But durability is not considered in energy codes at this time.

Energy codes strive to provide cost-effective criteria. For example, commercial building criteria in ASHRAE 90.1 generally has a payback period of less than 10 years and residential building criteria in ASHRAE 90.2 generally has a payback period of less than 20 years. See resource page Life-Cycle Cost Analysis.

Building envelope requirements in codes generally include minimum insulation levels for walls, roofs, and floors, as well as window requirements. These generally vary with climate region, since more insulation is cost-effective in cold or extremely hot regions.

Mechanical system requirements include minimum equipment efficiency requirements, insulation requirements for ducts and piping, and controls for off-hours and dead bands (commercial).

Commercial building requirements for lighting include total building wattage requirements for interior and exterior lighting. Controls are generally required to assure lighting is turned off when facilities are unoccupied. This can be achieved through programmable controls or occupancy sensors.

C. Prescriptive versus Performance Criteria

Codes generally have prescriptive and performance paths for compliance. Prescriptive paths are easy-to-use tables that contain required minimum or maximum values. Performance paths are used to trade one energy saving measure for another. For instance, if the wall insulation does not meet the prescriptive requirements, but the ceiling insulation exceeds the prescriptive requirements, then using a performance method may show compliance of the whole building with the code. Prescriptive paths are commonly used for typical buildings in states with newly adopted codes. Once designers become familiar with performance software, these become more popular. Some performance methods can be used to show energy savings beyond code, and are used for sustainability programs or state tax credits.

In prescriptive tables, opaque elements such as walls and roofs will have requirements in terms of thermal resistance (R-values) and thermal transmittance (U-factors). The U-factor includes the effects of insulation as well as framing members and interior and exterior finishes. The "overall" R-value is the reciprocal of the U-factor. The "added" R-value is the R-value of the added insulation, which is a simpler way of stating the requirement since insulation materials are labeled for R-value. The effect of framing and building materials other than insulation does not have to be calculated for prescriptive tables with "added" R-value requirements. For fenestration (windows and associated frames) the requirements are in terms of U-factor and solar heat gain coefficient (SHGC). Some codes have pre-calculated U-factors for walls, roofs, or windows so that the pre-calculated values can be easily compared to the prescriptive requirements.

For walls with thermal mass (such as concrete, masonry, adobe, or logs) R-values are not a true indicator of energy performance. These materials have a relatively low R-value, yet buildings constructed with these materials perform well and are comfortable in many climates. Thermal mass absorbs heat, thereby reducing and delaying the effects of outdoor temperature extremes on the HVAC system, especially when temperatures fluctuate with highs or lows between 50 to 75°F (10 to 25°C). In most climates, buildings with insulated mass walls will save energy compared to buildings without mass with the same R-value. In many southern and western climates, mass walls without insulation will perform as well as non-mass walls with insulation. In commercial buildings where cooling demand often peaks in the afternoon due to the loads from people and equipment, walls with thermal mass can absorb and lessen this peak. Since the mass reduces peaks in mechanical system loads, first costs for HVAC equipment may also be reduced in some climates. Most energy codes allow an adjustment for wall thermal mass in the prescriptive portion.

The performance paths in energy codes generally allow the use of an easy-to-use computer trade-off program or a detailed energy budget method. Generally the more complicated the compliance tool, the more flexibility the designer is allowed. Trade-off tools also allow for innovation in design and materials. COMcheck™ is an easy-to-use program for determining commercial building compliance for ASHRAE 90.1, IECC, and many state codes. REScheck™ (formerly MECcheck) is an easy-to-use program for determining residential building compliance with the MEC, IECC, and many state codes. A detailed computer-based energy analysis program such as DOE2 and Visual DOE4.0 calculate yearly energy consumption on an hourly basis. Such programs are useful when using the energy budget method because other simpler compliance tools do not take into account special features of the building or its components. The energy budget method compares the annual energy use of a building that meets prescriptive requirements with the proposed building to determine compliance. Codes provide rules and guidelines for the energy budget method.

Application

Energy codes provide minimum building requirements that are cost-effective in saving energy. The energy saved is a cost savings to the building owner through lower monthly utility bills, and smaller and thus less expensive HVAC equipment. Energy codes contribute to sustainability by saving energy and protecting the environment.

Relevant Codes and Standards

Additional Resources

WBDG

Products and Systems

Federal Green Construction Guide for Specifiers:

Federal Government

Organizations

Publications

  • ASHRAE 90.1-2010 User's Manual
  • ASHRAE 90.2-1997 User's Manual
  • Department of Energy, Office of Energy Efficiency and Renewable Energy [Docket No. EE-DET-02-001] "Building Energy Standards Program: Determination Regarding Energy Efficiency Improvements in the Energy Standard for Buildings, Except Low-Rise Residential Buildings", ASHRAE/IESNA Standard 90.1-1999, Federal Register, Vol. 67, No. 135, Monday July 15, 1992, Notices.
  • GSA LEED® Applications Guide
  • GSA LEED® Cost Study
  • The New Standard 90.1 by R. Jarnagin, M. McBride, M. Schewedler, J. Howley, Jr. ASHRAE Journal, March 2000, vol. 42, no. 3.

Energy Design and Analysis Tools