Ammunition and Explosive Storage Magazines
RC Stradley 33-15-16-6
| Approved for New Construction | ECM Designation | Designer & Drawing Number | DDESB Approval Date |
|---|---|---|---|
| No | 7-BAR | Unknown RC Stradley 33-15-16 | Acceptance based on COE analysis |
Comments/Design Considerations -
Very similar to 33-15-61, which is a 7-Bar ECM. Only differences were the use of a 10' door and 3,000 psi concrete vice a 12' door and 2,500 psi concrete. Doors and headwall were analyzed and were found to meet 7-Bar criteria. COE Huntsville e-mail of 24 January 2003 to DDESB documents results of review and analvsis.