Ammunition and Explosive Storage Magazines

by Transystems Corporation (Compiled for the Unified Facilities Criteria (UFC))

RC Stradley 33-13-02

Approved for New Construction ECM Designation Designer & Drawing Number DDESB Approval Date
No 7-BAR OCE RC Stradley 33-13-02 26-Jan-99

Files for Reference -
Documentation -
Comments/Design Considerations -
A COE, Huntsville District, letter of 13 Apr 98 determined this ECM was a revision of 33-15-06 (a 7-Bar ECM) and recommended it be considered a 7-Bar ECM as well. A 26 Jan 99 DDESB letter approved use of ECM constructed in accordance with Drawing 33-13-02, as a 7-Bar magazine.
A provision of the approval was that the separation distances between the rear or side of these ECMs, as the PES, to the front of one of these ECMs, as an ES, was at least 360 feet. Side to side exposures between the PES and the ES are required to be separated in accordance with the appropriate entries for either 3-bar or 7-bar ECMs in accordance with Table 9-5 of DoD 6055.9-ST:).