Ammunition and Explosive Storage Magazines

by Transystems Corporation (Compiled for the Unified Facilities Criteria (UFC))

RC Arch ANG-DWG-89-115

Magazine MCE ECM Designation Designer & Drawing Number DDESB Approval Date
150 or 450 Undefined AF-NGB Magazine design designated by AF-NGB as ANG-DWG-89-115 7-Apr-89

Comments -
Known as the Fargo ECM (40 ft by 80-ft). Approved under Site Plan ANG Fargo-88-S1 thru S-5 Hector, Field, Fargo, ND.

Designer Considerations -
Approved for up to 450 pounds NEW HD 1.1. A QD of 250 feet applies to the sides of these ECM. A 700-foot QD arc applies to the front sector of these ECM, with one exception. When the MCE is 150 pounds of HD 1.1 or less, a 500-foot QD arc can be used from the front sector of these ECM. The front sector of the ECM is defined by arcs of plus and minus 15 degrees, drawn normal to the door.

Magazines (Earth-Covered and Above Ground) and Containers with Reduced News and/or Reduced QD