Comment On This Page
Search CCB
The VA has created two lists of contact people for a number of their documents. Please see the Technical Information Library Catalog and the Facilities Quality Service Contact List for this information.
These documents are available in the following format:
Adobe Acrobat (PDF)
| Title | Date | Downloads |
|---|---|---|
| Design Alerts Index | 01-2013 | 108 KB |
| 003C2B-DA-138 Indoor Water Features, Decorative Fountains: Recommend Non-Use | 04-19-2012 | 49 KB |
| 00CFM1A-DA-137 Spinal Cord Injury/Disorders Design Guide | 08-24-2011 | 567 KB |
| 00CFM1A-DA-136 Sustainable High Performance Concrete Structures | 03-08-2011 | 48 KB |
| 00CFM1A-DA-135 Low Pressure Hot Water Boilers | 05-14-2010 | 32 KB |
| 00CFM1A-DA-134 VA Adoption of Plenum Fans for Air-Handling Units Application | 05-17-2010 | 32 KB |
| 00CFM1A-DA-133 Cooking Equipment in Community Living Centers, with Revision 1 | 03-04-2010 | 37 KB |
| 00CFM1A-DA-132 Pharmacy Design Guidance - Update on Compliance with USP Chapter 797 "Pharmaceutical Compounding - Sterile Preparations" | 05-01-2008 | 170 KB |
| 00CFM1A-DA-131 Master Construction Specifications (MasterFormat 2004); VA Master Specifications are available here. | 10-2007 | 54 KB |
| FM-181A-DA-130 Direct-Buried Steam and Condensate Systems Reinsulation | 01-18-2007 | 40 KB |
| FM-181A-DA-129 Steam Trap Monitoring Systems | 01-18-2007 | 27 KB |
| FM-181A-DA-128 Physical Security Strategies for New and Renovation VA Construction | 04-27-2006 | 37 KB |
| FM-181A-DA-121 Mycobacterial Laboratories (BSL3) Labs Architectural and Engineering Controls Update | 09-15-2004 | 34 KB |
| FM-181A-DA-120 Installing, Maintaining and Monitoring of HEPA Filters | 04-13-2004 | 99 KB |
| FM-181A-DA-117 Steam Traps: Update on Fixed Orifice or Venturi Types | 05-13-2003 | 14 KB |
| FM-181A-DA-114 Technical Information Library (TIL) | 09-15-2002 | 18 KB |
| FM-181A-DA-113 Medical Gas (Oxygen) for Nursing Homes | 08-05-2002 | 16 KB |
| FM-181A-DA-112 Ceiling Mounted Utility Columns for Operating Rooms | 04-19-2011 | 39 KB |
| FM-181A-DA-111 Control Protocols for Building Automation | 06-19-2002 | 18 KB |
| FM-181A-DA-110 Boiler Plant Burner Performance | 01-16-2002 | 18 KB |
| FM-181A-DA-109 Orifice Steam Traps | 12-04-2001 | 11 KB |
| FM-181A-DA-105 Manufacturer Names and Model Numbers | 06-19-2000 | 14 KB |
| FM-181A-DA-104 Boiler Plant Make-up Water Alkalinity Control | 04-12-2000 | 27 KB |
| FM-181A-DA-102 Refrigerant Leak Detectors for Chillers | 10-25-1999 | 16 KB |
| FM-181A-DA-100 Plan for Updating Standards, Topic: VA Master Construction Specifications | 09-23-1999 | 18 KB |
| FM-181A-DA-98 Heat Strengthened and Fully Tempered Glass | 07-30-1999 | 19 KB |
| FM-187C-DA-95 Building Humidification | 01-13-1999 | 17 KB |
| FM-187C-DA-91 Energy Efficiency, Topic: Computers, Copiers, and Printers | 10-22-1998 | 18 KB |
| FM-187C-DA-85 Electric Motor Maintenance | 03-02-1998 | 17 KB |
| FM-187C-DA-78 Roof Inspection and Maintenance | 11-07-1997 | 15 KB |
| FM-187C-DA-77 Emergency Shut Down of Refrigeration Equipment | 10-23-1997 | 17 KB |
| FM-187C-DA-76 Emergency Heating for Patient Care Areas | 10-15-1997 | 15 KB |
| FM-187C-DA-69 Structural Steel in Interstitial Space Needs to be Painted | 04-23-1997 | 16 KB |
| FM-187C-DA-68 Exterior Insulation Finish Systems (EIFS) Failures Create New Solutions | 04-21-1997 | 16 KB |
| FM-187C-DA-65 Re-bars Go Metric | 02-20-1997 | 17 KB |
| FM-187C-DA-57 Compliance with the Randolph-Sheppard Act in Leasing and Construction | 07-23-1996 | 18 KB |
| FM-187C-DA-56 Control Joints in Concrete Floor Slabs | 07-12-1996 | 14 KB |
| FM-187C-DA-55 Renovation Projects and Firesafing Existing Facilities | 07-11-1996 | 14 KB |
| FM-187C-DA-54 A Good Design Analysis Saves Money! | 07-10-1996 | 15 KB |
| FM-187C-DA-51 Ultrasonic Testing of Welded Joints | 04-02-1996 | 14 KB |
| FM-187C-DA-50 Heliport Design | 03-08-1996 | 16 KB |
| FM-187C-DA-48 Kitchen Floors Under Rack Ovens | 02-05-1996 | 14 KB |
| FM-187C-DA-47 Natural Disaster Mitigation | 12-06-1995 | 15 KB |
| FM-187C-DA-46 Lead Exposure in Construction | 11-08-1995 | 19 KB |
| FM-187C-DA-45 National Pollution Discharge Elimination System | 11-07-1995 | 19 KB |
| FM-187C-DA-44 Hydraulic Elevators Oil Supply Lines | 10-16-1995 | 17 KB |
| FM-187C-DA-43 Incomplete Demolition Drawings | 09-20-1995 | 18 KB |
| FM-187C-DA-42 Existing Utilities | 09-20-1995 | 19 KB |
| FM-187C-DA-41 Old Metal Studs | 09-06-1995 | 15 KB |
| FM-187C-DA-40 Shaft Walls | 08-31-1995 | 15 KB |
| FM-187C-DA-39 Motors and Starters | 08-17-1995 | 15 KB |
| FM-187C-DA-33 Mechanical Equipment in Interstitial Space | 05-03-2011 | 37 KB |
| FM-187C-DA-32 Elevator Hoistway Smoke Venting | 04-13-1995 | 16 KB |
| FM-187C-DA-31 Radiographic/Fluoroscopic Rooms Ceiling Layout Coordination | 03-07-1995 | 16 KB |
| FM-187C-DA-24 Architectural and Structural Design of Building Exterior - Coordination Problems | 11-30-1994 | 15 KB |
| FM-187C-DA-22 Structural Steel Prime Painting within Interstitial Space | 11-21-1994 | 15 KB |
| FM-187C-DA-21 Architectural Features - Missing Structural Designs | 11-21-1994 | 15 KB |
| FM-187C-DA-18 Atrium Skylights Maintenance Provisions | 11-09-1994 | 15 KB |
| FM-187C-DA-17 Coordination Problems Between Trades | 11-09-1994 | 16 KB |
| FM-187C-DA-16 Fixed Equipment Utilities | 11-07-1994 | 15 KB |
| FM-187C-DA-15 Metal Studs | 11-03-1994 | 15 KB |
| FM-187C-DA-14 Vertical Ducts Passing Through Interstitial Spaces - Protection | 11-03-1994 | 15 KB |
| FM-187C-DA-13 Leaded Paints On-Site Removal | 11-01-1994 | 15 KB |
| FM-187C-DA-11 Lead Abatement | 10-25-1994 | 15 KB |
| FM-187C-DA-09 Radiology Area Walls | 10-25-1994 | 15 KB |
| FM-187C-DA-06 Smoke Removal System for Interstitial Space - HVAC Design Criteria | 07-11-1994 | 15 KB |